Agilent Technologies 6495D mass spectrometer
Agilent Technologies 6495D mass spectrometer — Liquid chromatography mass spectrometry lc ms with Pumping speed 4.8×10⁻⁵ m³/h.
The 6495D is a triple quadrupole LC/MS with Agilent Jet Stream electrospray ionization, configured for PFAS analysis in complex matrices. It sustains over 13,700 continuous injections with 7.5% peak-area RSD, using iFunnel modes tuned per analyte. It serves as the detection and quantification stage in LC/MS/MS workflows requiring long-run robustness.
Full specifications
| Pumping speed | 0.8 mL/min |
| Centrifugation Speed | 4000 rpm |
| Column temperature | 45 °C |
| Extraction Solvent Volume | 10 mL |
| Nebulizer Gas Pressure | 24 psi |
| Peak Area Rsd | 7.5 % |
| Sample volume | 2 μL |
| Software version mfr | 2.2 |
| Minimum required software version mfr | 1.0 |
| Number of continuous injections mfr | 13700 injections |
| Gradient %B at 1.5 min mfr | 90 |
| Stop time mfr | 3.0 min |
| Vortex mixing time mfr | 10 minutes |
| PFHxS precursor m/z mfr | 398.9 m/z |
| PFHxS product m/z mfr | 99.0 m/z |
| PFHxS retention time mfr | 1.44 min |
| PFOA precursor m/z mfr | 413.0 m/z |
| PFOA product m/z mfr | 369.0 m/z |
| PFOA retention time mfr | 1.39 min |
| PFNA precursor m/z mfr | 463.0 m/z |
| PFNA product m/z mfr | 419.0 m/z |
| PFNA retention time mfr | 1.52 min |
| PFOS precursor m/z mfr | 498.9 m/z |
| PFOS product m/z mfr | 80.0 m/z |
| PFOS retention time mfr | 1.67 min |
| iFunnel mode PFHxS/PFOS mfr | Large Mol. Mol. |
| iFunnel mode PFOA/PFNA mfr | Fragile Fragile |
| Vortex mixing duration mfr | 10 minutes |
| Retention time PFHxS mfr | 1.44 min |
| Retention time PFOA mfr | 1.39 min |
| Retention time PFNA mfr | 1.52 min |
| Retention time PFOS mfr | 1.67 min |
| Precursor m/z PFHxS mfr | 398.9 m/z |
| Product m/z PFHxS mfr | 99.0 m/z |
| Precursor m/z PFOA mfr | 413.0 m/z |
| Product m/z PFOA mfr | 369.0 m/z |
| Precursor m/z PFNA mfr | 463.0 m/z |
| Product m/z PFNA mfr | 419.0 m/z |
| Precursor m/z PFOS mfr | 498.9 m/z |
| Product m/z PFOS mfr | 80.0 m/z |
| Operating system name, version mfr | 10 bit |
| G5654A mfr | 1260 Pump |
| G7104A mfr | 1290 Pump |
| G7104C mfr | 1260 Pump |
| G7110B mfr | 1260 Pump |
| G7111A mfr | 1260 VL |
| G7111B mfr | 1260 Pump |
| G7112B mfr | 1260 Pump |
| G7120A mfr | 1290 Pump |
| G7131A mfr | 1290 Pump |
| G7131C mfr | 1260 Pump |
| G7132A mfr | 1290 Pump |
| G7114A mfr | 1260 Detector |
| G7114B mfr | 1290 Detector |
| G7115A mfr | 1260 WR |
| G7117A mfr | 1290 FS |
| G7117B mfr | 1290 Detector |
| G7117C mfr | 1260 HS |
| G7121A mfr | 1260 Detector |
| G7121B mfr | 1260 Spectra |
| G7162A mfr | 1260 Detector |
| G7162B mfr | 1290 Detector |
| G7165A mfr | 1260 Detector |
| G6160B mfr | Agilent InfinityLab Pro iQ Mass Detector Detecto |
| G6170A mfr | Agilent InfinityLab Pro iQ Plus Mass Detector De |
| G7123B mfr | 1290 Detector |
| G6495D mfr | 6495 LC/MS |
| G6475A mfr | 6475 LC/MS |
| G6465B mfr | Ultivo Triple Quadrupole LC/MS LC/MS |
| Agilent 2D-LC System Driver mfr | 2 Driver. |
| Agilent 1200 Infinity Series High Dynamic Range DAD Solution mfr | 7117 applications |
| Valve-thermostat Cluster maximum columns mfr | 32 columns |
| Stop Time mfr | 3.0 min |
| Injection volume (performance monitoring) mfr | 2 μL |
| Injection volume (matrix) mfr | 10 μL |
| Performance monitoring sample total volume mfr | 1.38 mL |
| Matrix injection total volume mfr | 137 mL |
| Grand total matrix volume mfr | 138.38 mL |
| Equivalent 2 μL sample injections mfr | 69190 |
| Matrix injections count mfr | 13700 |
| Performance monitoring injections count mfr | 690 |
| Mobile phase A mfr | 2 acetate |
| Collision energy PFOS mfr | 52 V |
| Collision energy PFHxS mfr | 43 V |
| Collision energy PFOA mfr | 7 V |
| Collision energy PFNA mfr | 8 V |
| Mobile Phase A mfr | 2 acetate |
| Mobile Phase B mfr | ACN ACN |
| Sample preparation salt part number mfr | 5982 CH |
Description
Construction and series positioning
The 6495D is the high-sensitivity triple quadrupole LC/MS in Agilent's 6400 series, distinguished from the 6475 by its iFunnel ion guide and AJS-ESI source. The iFunnel operates in two modes: 'Large Mol.' for PFHxS/PFOS and 'Fragile' for PFOA/PFNA, allowing per-analyte tuning. This modification targets PFAS workflows in complex matrices such as salmon, where long unattended sequences are required.
Behavior under load
The system was validated over 13,700 continuous injections with a peak-area RSD of 7.5%, demonstrating stability across extended runs. PFAS analytes elute between 1.39 and 1.67 min under the tested gradient (90% B at 1.5 min, stop time 3.0 min), with precursor/product transitions such as PFHxS 398.9→99.0 and PFOA 413.0→369.0. Collision energy for PFOS is 52 V. These conditions reflect the instrument's performance in a defined method, not universal defaults.
Installation and control
Operation requires InfinityLab Assist Control Software version 2.2 (minimum 1.0). The software release note covers compatibility with LC modules, detectors, valve drives, and LC/MS instruments. Nebulizer pressure is set to 24 psi in the PFAS method. Sample preparation includes vortex mixing for 10 minutes and use of a salt part number 5982.
Integration & Operating Notes
The 6495D must be controlled with InfinityLab Assist Control Software 2.2; version 1.0 is the minimum but may not support all features. Verify the installed software before commissioning, as older versions can limit instrument control or data integrity.
Use 'Large Mol.' mode for PFHxS and PFOS, and 'Fragile' mode for PFOA and PFNA. Selecting the wrong mode can reduce sensitivity or cause fragmentation, so method parameters must be set per analyte group.
The robustness test exceeded 13,700 injections; at such duty cycles, schedule preventive maintenance of the AJS-ESI source and iFunnel to preserve 7.5% peak-area RSD. Consult the manual for cleaning intervals based on matrix load.
Selection & Integration Q&A
Choose the 6495D for PFAS or trace analysis in complex matrices requiring iFunnel modes and long unattended runs (validated >13,700 injections). The 6475 lacks the iFunnel and is suited for routine, less demanding workflows.
The 6495D requires an LC module compatible with InfinityLab Assist Control Software 2.2 (minimum 1.0). The release note lists supported LC modules, detectors, and valve drives; ensure the LC stack is on the compatibility list.
Base delivery excludes LC columns, PFAS sample prep salts (e.g., part 5982), and source cleaning supplies. Plan for regular AJS-ESI source maintenance and iFunnel cleaning; intervals depend on matrix load and injection count.