Agilent Technologies Reliable routine analysis gas chromatography system
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Reliable routine analysis gas chromatography system

Agilent Technologies Reliable routine analysis gas chromatography system — Gas chromatography.

The Agilent 7820A GC System is a gas chromatograph available with EPC for all inlets and detectors or EPR for select inlets and detectors, operating from 8 to 425 °C with a maximum inlet temperature of 400 °C. It supports split ratios up to 250 and flow adjustment to 200 mL/min, with a 100 Hz data acquisition rate. It serves as the analytical core for routine GC separations in laboratory workflows.

Agilent Technologies GC Systems Series — Model Comparison & Selection

Model Operating temperature, °CSample volume, milliliterCarrier gasCollision gas nitrogen, mL/minColumn temperature, °CData rate, Hz
Reliable routine analysis gas chromatography system Current 8...425—————
Accurate and Reliable GC System with Faster Cycle Times —0.00221.58510

Full specifications

Core Performance & Functional Specifications
Maximum Data Acquisition Rate 100 Hz
Peak Area, C13 45.2143 pA
Peak Area, C14 45.5790 pA
Peak Area, C15 457.8670 pA
Peak Area, C16 456.6820 pA
Retention Time, C13 3.7843 min
Retention Time, C14 4.4213 min
Retention Time, C15 5.0369 min
Retention Time, C16 5.6238 min
Maximum split ratio mfr 250
Minimum detection level (MDL) mfr 3 tridecane
Linear dynamic range mfr 107
NPD selectivity mfr 25000...1 gP/gC
NPD dynamic range mfr 104 P
heated valve control mfr two heated valves valves
PCOC minimum column id mfr 0.250 id
instruments per PC (EZChrom Compact) mfr two instruments instruments
Electrical, Power & Drive Specifications
Mains frequency mfr 47.5...63 Hz
Operating Conditions, Environment & Protection
Operating temperature 8...425 °C

Description

Construction and series positioning

The 7820A GC System is the base gas chromatograph in a series that also includes the 7650A and 7693A automatic liquid samplers and the 7697A and 8697 headspace samplers. Unlike those dedicated front-end sampling devices, the 7820A is the separation and detection instrument itself. Two pneumatic configurations exist: EPC (electronic pneumatics control) for all inlets and detectors, and EPR (electronic pneumatics regulation) for select inlets and detectors. The system uses a 5-button keypad for local control and supports optional automated injectors and samplers.

Operating behavior

Control, software, and installation

Local control is via a 5-button keypad. The system requires a mains frequency of 47.5–63 Hz. Software options include OpenLAB CDS Workstation/Workstation Plus, OpenLAB CDS VL Workstation/Workstation Plus, OpenLAB CDS ChemStation Edition (C.01.05 or higher), EZChrom Edition (A.04.05 or higher), OpenLAB CDS ChemStation VL, EZChrom VL, OpenLAB CDS EZChrom Compact, and DA Express (China and Russia only). Automated injectors and samplers are optional and not part of the base instrument.

Integration & Operating Notes

Electrical
Mains frequency must stay within 47.5–63 Hz

The instrument is specified for 47.5–63 Hz mains frequency. Operating outside this window risks unreliable electronics and invalid run data; verify site power quality before installation, especially on generator or unstable supply.

Factory Specification Sheet
Process Limits
Inlet temperature must not exceed 400 °C

While the oven reaches 425 °C, the inlet maximum is 400 °C. Setting an inlet method above this limit can degrade septa, columns, and inlet hardware; method development must cap inlet temperature accordingly.

Factory Specification Sheet
Control & I/O
Software must meet minimum version for control

OpenLAB CDS ChemStation Edition requires C.01.05 or higher and EZChrom Edition requires A.04.05 or higher. Older software builds will not support the instrument; confirm the workstation version before commissioning.

Brochure 5991 5345EN
Maintenance
Automated samplers are optional, not base delivery

The 7650A/7693A automatic liquid samplers and 7697A/8697 headspace samplers are separate optional accessories. Budget and plan for them explicitly if unattended operation is required; the base 7820A includes only the GC with keypad and pneumatics.

Brochure 5991 5345EN

Selection & Integration Q&A

When should I choose the 7820A GC System instead of a sibling sampler like the 7697A headspace sampler?

The 7820A is the gas chromatograph itself (oven, inlets, detectors, pneumatics). The 7697A and 8697 are headspace samplers that feed a GC; the 7650A and 7693A are liquid autosamplers. Choose the 7820A when you need the separation/detection instrument; add a sampler only for automated sample introduction.

What software and control infrastructure must be in place to operate the 7820A?

The system requires a compatible Agilent data system: OpenLAB CDS ChemStation Edition C.01.05 or higher, EZChrom Edition A.04.05 or higher, or OpenLAB CDS Workstation/Workstation Plus. Local control is via the 5-button keypad. Confirm the workstation version and PC meet the software prerequisites before installation.

What maintenance and accessories are not included with the base 7820A delivery?

Automated liquid samplers (7650A, 7693A) and headspace samplers (7697A, 8697) are optional and not part of the base instrument. Columns, consumables, and the data-system software licenses are also separate. Plan for these items and for the software version requirements when budgeting.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 7820A GC System
Brochure ·1,4 МБ ·8 pp.
View PDF