Agilent Technologies 5 Laser Flow Cytometer, NovoCyte Penteon
Agilent Technologies 5 Laser Flow Cytometer, NovoCyte Penteon — Research flow cytometry.
The NovoCyte Penteon is a five-laser solid-state flow cytometer with onboard thermoelectric cooling, built for high-parameter research acquisition. It pairs a 6.5 mL/min sheath flow with a 5–120 µL/min sample flow and up to 100,000 events/s, distinguishing it from the one-to-three-laser Advanteon and four-laser Quanteon siblings.
Agilent Technologies Flow Cytometer Systems Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Sample flow rate, µL/min | Sheath flow rate, mL/min | Volumetric absolute count precision, % | Laser power, W | Print technology |
|---|---|---|---|---|---|---|
| 5 Laser Flow Cytometer, NovoCyte Penteon Current | — | 5...120 | 6.5 | 5 | 0.405 | Solid state laser with o |
| 1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon | — | 5...120 | 6.5 | 5 | 0.405 | Solid state laser with o |
| 1-3 laser benchtop flow cytometer, NovoCyte | 3×10⁻⁶ | 5...120 | 6.5 | 5 | — | — |
| 4 Laser Flow Cytometer, NovoCyte Quanteon | — | 5...120 | 6.5 | 5 | 0.405 | Solid state laser with o |
Full specifications
| Laser power | 405 mW |
| Print technology | Solid state laser with onboard thermal-electric cooling |
| Sample Flow Rate | 5...120 μL/min |
| Sheath Flow Rate | 6.5 mL/min |
| Ssc Sensitivity | 0.1 μm |
| Volumetric Absolute Count Precision | 5 % |
| Laser beam profile mfr | 10 μm |
| Fluorescence detection mfr | Silicon photomultiplier with individual photodet |
| FSC sensitivity mfr | 0.4 μm |
| Fluorescence threshold sensitivity mfr | 40 MESF |
| Fluorescence resolution mfr | 3 % CV |
| Flow cell mfr | 170 μm |
| Sample acquisition rate mfr | 100000 events/second |
| Sample acquisition volume mfr | 5 mL |
| Manual sample format mfr | 12 tube |
Description
Architecture and series positioning
- The Penteon is the five-laser member of the NovoCyte family; the same datasheet covers the Quanteon (four lasers) and Advanteon (one to three lasers), so laser count is the primary selection axis.
- Each fluorescence channel has its own silicon photomultiplier photodetector rather than a shared array, supporting independent channel gain.
- The 170 µm flow cell and 10 µm laser beam profile define the optical core; the 405 mW laser figure is the matched laser-power spec.
- Manual sample format accepts 12 tubes; sample acquisition volume is 5 mL.
Measurement behavior
- Sensitivity is specified as 0.4 µm FSC and 0.1 µm SSC; fluorescence threshold sensitivity is 45 MESF with 3 % CV fluorescence resolution.
- Volumetric absolute counting carries 5 % precision, so absolute counts can be reported without reference beads within that tolerance.
- Sample flow is adjustable from 5 to 120 µL/min against a 6.5 mL/min sheath flow; acquisition rate reaches 100,000 events/s.
Operation and control
- The solid-state laser is cooled by an onboard thermoelectric stage, so the instrument manages its own thermal load rather than relying on facility chilled water.
- The attached datasheet digest contains no installation, connection or control sections; those specifics must come from the instrument manual, which was not supplied.
Integration & Operating Notes
The 100,000 events/second figure is the stated sample acquisition rate ceiling. Samples concentrated enough to demand more than this will be acquired outside specification, so dilute high-concentration preparations or accept that data beyond the limit is not covered by the rated performance.
Selection & Integration Q&A
Pick the Penteon when the panel needs five laser lines; the Quanteon covers four and the Advanteon one to three. All three share the datasheet, so move down the series only when the extra laser line is not required by the panel.
The fluidics expect a 6.5 mL/min sheath flow and a sample flow adjustable over 5–120 µL/min, with 12-tube manual loading and 5 mL acquisition volume. Sheath and waste containers sized for continuous 6.5 mL/min draw are required; the datasheet gives no pressure or tubing-fit values.
Acquisition is rated to 100,000 events/s with 5 % volumetric count precision. The supplied datasheet contains no ambient temperature, humidity or duty-cycle figures, so continuous-run limits and room cooling must be confirmed from the instrument manual before scheduling long runs.
The supplied documents list no maintenance kit, sheath fluid, cleaning solutions, tubes or cables as included. Consumables and the service schedule are absent from the datasheet; obtain the accessory list and interval table from the Penteon manual or Agilent before budgeting.