Agilent Technologies CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer

Agilent Technologies CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer — Automated electrophoresis.

The CE-SDS Protein Analysis Capillary Array is the consumable separation array for the Agilent ProteoAnalyzer system, a parallel capillary electrophoresis instrument. It supports denaturing protein sizing from 10 to 240 kDa across 12 capillaries in parallel, with a 3-log dynamic range and CCD-based detection. The array is the replaceable separation element that defines the system's CE-SDS analysis capability.

Agilent Technologies Proteoanalyzer Systems Series — Model Comparison & Selection

Model SensitivityRun time, minSoftwareAnalysis time for 12 samples, minutesDetector typeLower marker size, kDa
CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer Current —30Agilent ProSize data ana30charge-coupled device —
Protein Capillary Electrophoresis Instrument 130———6

Full specifications

Core Performance & Functional Specifications
Analysis Time For 12 Samples 30 minutes
Detector type charge-coupled device camera
Run Time 30 minutes
Software Agilent ProSize data analysis software
Protein size range mfr 10...240 kDa
Samples analyzed in parallel mfr 12 samples
Dynamic range mfr 3 log
Separation technique mfr automated parallel capillary electrophoresis sod
Sample plate format mfr 96 plate
Protein size separation range mfr 10...240 kDa
Capillary cleaning mfr automatic cleaning, reconditioning and refilling
protein size range mfr 10...240 kDa
dynamic range mfr 3 log
parallel sample capacity mfr 12 samples
sample plate format mfr 96 plate
sample drawers mfr three three
Standards, Safety & General Data
Standard Warranty one-year

Description

Construction and series positioning

Separation behavior and working range

Installation and operation

Integration & Operating Notes

Compatibility
Array is dedicated to the ProteoAnalyzer platform only

The array is supplied as part of the ProteoAnalyzer system bundle and is not described as compatible with other capillary electrophoresis instruments. System-level integration (detector, sample plate handling, software) is provided by the instrument; the array should not be treated as a universal CE consumable.

Brochure: dependable denaturing protein electrophoresis ProteoAnalyzer 5994-6716EN Agilent
Process Limits
Protein sizing limited to 10–240 kDa under denaturing CE-SDS

The array's specified working range is 10–240 kDa for denatured proteins. Samples outside this range are not covered by the verified specification; sizing accuracy and detection may be invalid outside the stated range. The 3-log dynamic range applies within this size window.

Factory Specification Sheet
Maintenance
Array is a replaceable consumable; no service interval stated

The verified facts do not specify a replacement interval, cleaning procedure, or storage condition for the array. Users should follow the instrument's installation and introduction documentation for array handling; no maintenance schedule is available in the provided sources.

Brochure: dependable denaturing protein electrophoresis ProteoAnalyzer 5994-6716EN Agilent

Selection & Integration Q&A

When should I choose the CE-SDS Protein Analysis Capillary Array rather than the Protein Capillary Electrophoresis Instrument sibling?

The array is a consumable separation element, not an instrument. Choose the array when you already have the ProteoAnalyzer instrument and need to run CE-SDS denaturing protein analysis (10–240 kDa, 12 samples in parallel). The sibling instrument is the platform itself; the array is ordered as its replacement separation component.

What adjacent system components are required to use this array, and are they included?

The array operates only within the ProteoAnalyzer system bundle, which includes the instrument, software, computer, and installation/introduction. The array itself does not include the instrument, detector (CCD camera), sample plate handling, or software. Confirm the platform is present before ordering the array as a consumable.

What are the mounting and environment limits for the array?

No mounting, environmental, or duty-cycle limits are specified for the array in the verified facts. Installation and introduction are part of the system bundle; operational limits are governed by the ProteoAnalyzer instrument. The array should be installed per the system's installation documentation.

What maintenance schedule and consumables are required for the array, and what is not included in base delivery?

No replacement interval, cleaning protocol, or storage condition is stated in the verified facts. The array is a replaceable consumable; the base system bundle includes the array, instrument, software, computer, and installation. Additional arrays, reagents, and sample plates are not described as included and should be ordered separately per the system documentation.