No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301

Agilent Technologies Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301 — Vacuum technologies.

The RPS-1401/301 is a fast roughing Roots pumping station rated at 1400 m3/h, positioned between the 1000 m3/h high-speed and 2000 m3/h fast-roughing siblings in the RPS series. It is built for high-throughput roughing of large vacuum chambers where short pump-down cycles matter, using a Roots stage backed by a rotary-vane or dry-scroll forepump.

Agilent Technologies Roots Pumping Systems Rps Series — Model Comparison & Selection

Model Diffusion pump pumping speed, L/s
Fast Roughing Roots Pumping Station 1400 m3/h; RPS-1401/301 Current 50
High Speed Rotary Pumping Station 4000 m3/h; RPS-4001/631 50

Full specifications

Core Performance & Functional Specifications
Diffusion Pump Pumping Speed 50 L/s
Vacuum gauge measurement range mfr 6 pressure
Dry scroll pump typical size mfr 3...30 h
Turbomolecular pump pumping speed mfr 70...3 L/s
Interfaces, Connections & Control
Turbomolecular pump controller protection class mfr 54

Description

Construction and series positioning

Behavior and media

Installation and operation

Integration & Operating Notes

Process Limits
Do not treat the 50 L/s figure as the Roots stage rating

The only matched performance value is a 50 L/s diffusion-pump pumping speed, a system-level number. The Roots station itself is a 1400 m3/h class roughing unit; using 50 L/s for roughing-line sizing would undersize the foreline and the backing pump.

Factory Specification Sheet
Mounting
Confirm inlet flange and foreline connection against the manual

The supplied documents do not state the inlet or exhaust flange standard for the RPS-1401/301. Before ordering mating hardware, verify the flange size and bolt pattern in the model instruction manual rather than assuming compatibility with other RPS sizes.

RPS Series Instruction Manual (model-specific section
Control & I/O
Roots stage must not start against atmospheric inlet pressure

Roots blowers in roughing stations are typically enabled only after the backing pump has pulled the chamber below a preset pressure; the start-pressure threshold and interlock logic for the 1401/301 are defined in the model manual and must be wired into the pump-down sequence.

RPS Series Instruction Manual, Operating Sequence

Selection & Integration Q&A

When should I choose the RPS-1401/301 rather than the 1000 m3/h or 2000 m3/h RPS siblings?

Pick the 1401/301 when the required roughing throughput falls between the high-speed RPS-1001/301 (1000 m3/h) and the fast-roughing RPS-2001/631 (2000 m3/h). If cycle time dominates, the 2000 m3/h unit gives more margin; if floor space or backing-pump size is the constraint, the 1000 m3/h high-speed unit is the closer fit.

What must be verified about the backing pump and foreline before integrating this station?

The station is a Roots stage on a backing pump; the foreline must be sized for the backing pump's exhaust, and the Roots stage must be enabled only below its start pressure. Confirm the backing-pump model, inlet flange and exhaust routing against the RPS-1401/301 manual, since the supplied brochures give no connection data.

What mounting and duty-cycle limits apply to the RPS-1401/301?

The supplied documents contain no model-specific mounting or duty-cycle data for this station. Installation position, ambient temperature limits and maximum continuous operating pressure must be taken from the RPS-1401/301 instruction manual; do not infer them from the e-mobility brochures, which cover product families only.

What is included in base delivery and what service items must be planned separately?

The verified facts list no accessories, cables or consumables for this model. Backing-pump oil, inlet flange seals and any controller cabling should be treated as separate items and confirmed against the RPS-1401/301 manual and order code; maintenance intervals are likewise manual-defined, not brochure-defined.

Dimensional Drawings & Technical Documentation

Technical documentation