Agilent Technologies NovoCyte flow cytometer
Agilent Technologies NovoCyte flow cytometer — Research flow cytometry.
The NovoCyte is a benchtop flow cytometer with up to five lasers and fully contained Class I laser optics, configured per application. It operates from 15–32 °C on a grounded three-pin supply and interfaces with a dedicated workstation, fluidics station, and optional NovoSampler/NovoSampler Pro. It is intended for multicolor fluorescence analysis of 12 × 75 mm, 1.5 mL, or 2.0 mL tube samples in research laboratories.
Full specifications
| Carryover | 0.1 percent |
| Laser | Solid state laser with on-board thermal-electric cooling and guaranteed thermal stability and beam quality. |
| Laser power | 20 laser |
| Sample Flow Rate | 5 adjustable |
| Sheath Flow Rate | 6.5 mL/min |
| Volumetric Absolute Count Precision | 5 % |
| Laser Beam Profile mfr | 10 beam. |
| Optical Alignment Procedure mfr | Fixed, no operator alignment required required |
| Fluorescence Detection mfr | Photomultiplier Tube Tube |
| FSC/SSC Sensitivity mfr | 0.5 μm |
| Fluorescence Resolution mfr | 3 CEN |
| Optical Filters mfr | User Exchangeable Exchangeable |
| Cell Size mfr | 0.2 μm |
| Flow Cell mfr | 170 cell |
| Sample Acquisition Rate mfr | 35000 events/second |
| Sample Delivery mfr | Positive-displacement syringe pump enabling dire |
| Sample Aspiration Volume mfr | 5 mL |
| Compatibility to Autosampler mfr | No fluidic tubing disassembly or re-connection r |
| Dimensions (with reagents containers) (W × D × H) mfr | 11.4 in |
| NovoClean solution container mfr | 500 mL |
| NovoRinse solution container mfr | 500 mL |
| Waste container mfr | 3 L |
| Waste filter (1 pcs) mfr | Waste filter filter |
| NovoRinse solution inlet filter (1 pcs) mfr | NovoRinse solution inlet filter filter |
| NovoClean solution inlet filter (1 pcs) mfr | NovoClean solution inlet filter filter |
| Clean the External Surface of the Instrument mfr | Keep the external surface of the instrument clea |
| Decontamination mfr | When suspecting contamination in the system. sys |
| Prime Fluidics System before Long-Term Storage mfr | No plan to run the instrument for more than two |
| Prime Fluidics System after Long-Term Storage mfr | Instrument has not been used for more than two w |
| Purge Fluidics System before Shipment mfr | The instrument needs to be shipped. shipped. |
| Calibrate the NovoCyte Fluidics Station or NovoCyte Fluidics Cart mfr | Abnormal warning about the liquid level in the r |
| Clean the Optical Filters mfr | The optical filters get dirty. dirty. |
| Clean Fluidics System mfr | • The CV of the data is larger than normal. • QC |
| Sample Injection Probe (SIP) Rinse mfr | Automated flying collar wash of inner and outer |
| Data Acquisition Software mfr | NovoExpress NovoExpress |
| Parameters mfr | Height and Area for FSC, SSC and all Fluorescent |
| Dynamic Range mfr | 24 scale |
| Compensation mfr | Full inter-beam matrix, during or post acquisiti |
| File Export mfr | 3.0 report |
| Data Report mfr | Automatic report. Customizable report. Batch PDF |
| Usage Monitor mfr | Comprehensive Transaction Log and System Log. Lo |
| Quality Control Instrument Daily QC mfr | Automatic daily quality control with Agilent Flo |
| Production QC mfr | Each instrument is verified for assembly integri |
| Sampling Manual Sample Loading mfr | 12 holder |
| Operation Requirements mfr | 15 kPa |
| Regulatory Compliance mfr | Indoor and Outdoor Use Use |
| Equipment Class mfr | Class I Laboratory Equipment Equipment |
| NovoFlow green threshold mfr | 0.9 L |
| NovoRinse green threshold mfr | 150 mL |
| NovoClean green threshold mfr | 150 mL |
| Waste container green threshold mfr | 2.8 L |
| NovoFlow red threshold mfr | 0.7 L |
| NovoRinse red threshold mfr | 100 mL |
| NovoClean red threshold mfr | 100 mL |
| Waste container full threshold mfr | 3 L |
| Automatic compensation stop condition mfr | 10000 μL |
| Automatic compensation threshold mfr | 100000 |
| Compensation sample concentration mfr | 1,000,000...2,000,000 mL |
| Weight | 51 lb |
| Instrument Dimension (W × D × H) mfr | 23.6 in |
| Instrument Weight mfr | 86.0 lb |
| NovoFlow sheath fluid container mfr | 3 L |
| NovoFlow sheath fluid in-line filter (2 pcs) mfr | NovoFlow sheath fluid in-line filter filter |
| NovoFlow sheath fluid inlet filter (1 pcs) mfr | NovoFlow sheath fluid inlet filter filter |
| Fluid Level Sensing mfr | Active sensing using weight sensors with automat |
| Fluid Container Capacity mfr | 3 waste |
| Operating temperature | 15 °C |
| Sound pressure | 60 dB |
| Storage temperature | 1 °C |
| Overvoltage Category mfr | Class II II |
| Pollution degree of the intended environment mfr | 2 |
| Degree of Ingress protection mfr | IPXO IPXO |
Description
Construction and series positioning
- The NovoCyte is a benchtop instrument with a Class I laser product classification (IEC/EN 60825-1:2014); lasers are fully contained and no special work area is required except during service by qualified Agilent personnel.
- The standard configuration supports up to five lasers; customized models other than the standard configuration are available, with laser and detection channel configurations detailed in Appendix A of the user manual.
- The instrument back side provides a power port, four communication ports, and five fluidic connection ports; plan cable and fluidic routing during installation.
- The base instrument is delivered with a workstation and monitor and a fluidics station; the fluidics cart and NovoSampler/NovoSampler Pro are optional accessories.
Behavior and sample handling
- Samples are run in 12 × 75 mm, 1.5 mL, or 2.0 mL tubes; the sample injection probe (SIP) is a mechanical movable part and may pinch or injure fingers, so keep hands clear during acquisition and tube placement/removal.
- Acquisition conditions include stop condition, flow rate, and threshold; fluorescence compensation and data analysis are performed in the NovoExpress software.
- The sheath in-line filter must be replaced when dirty to avoid excessive debris in the display, maintaining data quality and preventing flow cell contamination.
- The NovoCyte Fluidics Station must be calibrated; calibration is described in System Maintenance and ensures accurate fluidic performance.
Installation, control, and operation
- Operating temperature range is 15–32 °C and storage temperature range is 1–40 °C; the instrument weighs more than 51 lb (23 kg), so use sufficient assistance and proper lifting techniques when moving it.
- Sound pressure Lp < 60 dB(A) per DIN EN ISO 7779; the instrument is suitable for typical laboratory environments without hearing protection.
- The power cord must be inserted in a three-pin socket with a protective ground connection; use only the power cord shipped with the product and do not use it with any other product.
- Power Switch Light steady green indicates powered on; flashing green indicates the shutdown cleaning procedure. The LED Status Indicator shows green = normal, orange = warning, red = error; check the NovoExpress status bar for details when orange or red is shown.
- If leaks are detected, immediately turn off power by pressing and holding the power button on the front of the instrument for about 6–7 seconds, then contact the local Agilent representative.
- The instrument is classified as ISM Group 1, Class A equipment (CISPR 11/EN 55011), suitable for non-domestic establishments; potential EMC difficulties may arise in other environments.
- Do not operate in the presence of flammable gases or fumes, oxygen-enriched atmosphere, or flammable liquid/explosive gas or reagents; do not use solvents with an auto-ignition temperature below 200 °C.
- Only Agilent authorized personnel are allowed to remove instrument covers; always disconnect power cables and external circuits before removing covers.
- Data is automatically stored on the workstation hard drive; regularly back up data to a server or other storage devices to prevent loss.
Integration & Operating Notes
The power cord must be inserted in a three-pin socket with a protective ground connection to minimize shock hazard. Use only the power cord shipped with the product; do not use it with any other product, and source replacement cords from Agilent to ensure electrical safety and regulatory compliance.
The instrument weighs more than 51 lb (23 kg). Use sufficient assistance and proper lifting techniques when moving or lifting the product to avoid injury and equipment damage. Plan the bench location to keep the back-side power, communication, and fluidic ports accessible for routing.
Do not operate the instrument in the presence of flammable gases or fumes, oxygen-enriched atmosphere, or flammable liquid/explosive gas or reagents. Do not use solvents with an auto-ignition temperature below 200 °C; select reagents compatible with the instrument to avoid fire or explosion hazards.
If leaks are detected, immediately turn off the power by pressing and holding the power button on the front of the instrument for about 6–7 seconds, then contact the local Agilent representative. This quick power-off mitigates electrical and biohazard risks.
The sheath in-line filter must be replaced when dirty to avoid excessive debris in the display. This maintains data quality and prevents flow cell contamination; include filter inspection in the scheduled maintenance routine.
The NovoCyte Fluidics Station must be calibrated; the calibration procedure is described in System Maintenance. Regular calibration ensures accurate fluidic performance and should be scheduled alongside preventative maintenance and replacement of fluidic system consumables.
Data is automatically stored on the workstation hard drive. Regularly back up data to a server or other storage devices to prevent data loss if the hard drive is corrupted or files are deleted.
Only Agilent authorized personnel are allowed to remove instrument covers; always disconnect power cables and external circuits before removing covers. This prevents electric shock and laser exposure, and unauthorized service voids warranty.
Selection & Integration Q&A
Choose the standard configuration when your panel fits its laser/detection layout (Appendix A). Customized models other than the standard configuration are available for different laser needs. Add NovoSampler or NovoSampler Pro only if automated tube sampling is required; the base instrument runs tubes manually via the SIP.
The instrument requires a grounded three-pin power socket and the shipped power cord, plus a workstation and monitor and a fluidics station. The back side has four communication ports and five fluidic connection ports; route cables and fluidics accordingly. The fluidics cart and NovoSampler/NovoSampler Pro are optional.
Operate at 15–32 °C and store at 1–40 °C. Do not operate near flammable gases/fumes, oxygen-enriched atmospheres, or explosive reagents, and avoid solvents with auto-ignition below 200 °C. The instrument is ISM Group 1 Class A (CISPR 11), so EMC difficulties may arise outside non-domestic establishments.
Scheduled maintenance includes preventative maintenance, replacement of fluidic system consumables, and sheath in-line filter replacement when dirty; the fluidics station must be calibrated. Unscheduled tasks include priming, cleaning, decontamination, and purging before shipment. The fluidics cart and NovoSampler/NovoSampler Pro are optional, not included in the base instrument.