Agilent Technologies NovoSampler Pro
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies NovoSampler Pro

Agilent Technologies NovoSampler Pro — Metrology, Analytical & Laboratory Instrumentation.

The NovoSampler Pro is an automated sample loader for the NovoCyte flow cytometer, accepting a 24-position rack of 12 × 75 mm tubes or 96-, 48-, and 24-well plates. It performs programmable mix and rinse cycles (1 cycle, 10 s mix) at a 66 µL/min sample flow rate with a 10 µL sampling volume. It is used to automate sample acquisition from multi-well plates and tube racks in flow cytometry workflows.

Full specifications

Core Performance & Functional Specifications
Mix Cycles 1 cycles
Mixing Duration 10 s
Operating system Microsoft Windows®
Rinse Cycles 1 cycles
Sample Flow Rate 66 µL/min
Sample volume 90 plates
Sampling Volume 10 µL
Software NovoExpress
Supported tube rack mfr 24 tubes
Supported sample plate type mfr 96 plates
Minimum sample volume, 96-well V-bottom mfr 90 μL
Dead volume, 96-well V-bottom mfr 50 μL
Minimum sample volume, 96-well U-bottom mfr 90 μL
Dead volume, 96-well U-bottom mfr 50 μL
Minimum sample volume, 48-well plates mfr 210 μL
Dead volume, 48-well plates mfr 170 μL
Minimum sample volume, 24-well plates mfr 310 μL
Dead volume, 24-well plates mfr 270 μL
Minimum Sample Volume (96-well V-bottom) mfr 90 μL
Dead Volume (96-well V-bottom) mfr 50 μL
Minimum Sample Volume (96-well U-bottom) mfr 90 μL
Dead Volume (96-well U-bottom) mfr 50 μL
Minimum Sample Volume (48-well) mfr 210 μL
Dead Volume (48-well) mfr 170 μL
Minimum Sample Volume (24-well) mfr 310 μL
Dead Volume (24-well) mfr 270 μL
NovoCyte Flow Cytometer with NovoSampler Pro installed: Work space requirements (W × D × H) mfr 186 cm
Carryover rate mfr 0.1
Mix mode mfr orbital shaker shaker
Dead volume mfr 50 plates
I. mfr Revision History History
II. mfr Contact Information Information
III. mfr Trademark Trademark
IV. mfr Intended Use Use
V. mfr Using this Guide Guide
VI. mfr Conventions Conventions
VII. mfr Safety and Limitations Limitations
VIII. mfr Technical Support Support
Appendix A mfr Accessories and Consumables Consumables
Appendix B mfr Technical Specifications Specifications
QC dilution buffer volume mfr 1 mL
QC particles transfer volume to well mfr 150 μL
Single sample volume in well A2 mfr 150 μL
FSC-H threshold mfr 100000
Lymphocyte gate stop condition mfr 5000 events
Automatic shutdown countdown mfr 60 seconds
SIP collision auto-recovery time mfr 3 minutes
Laser self-test duration mfr 5...10 minutes
Dimensions, Weight & Mechanical Design
NovoSampler Pro Dimension (W × D × H) mfr 14.6 in
NovoSampler Pro Weight mfr 19.8 lb
Electrical, Power & Drive Specifications
Power requirements mfr 100...220 W
Operating Conditions, Environment & Protection
Operating temperature 15 °C
Operating Humidity mfr 80 condensing

Description

Construction and positioning

The NovoSampler Pro is a dedicated automation accessory for the NovoCyte flow cytometer, not a standalone instrument. It is the only sampler variant described in the operator's guide, and it supports a single tube-rack format: 24 positions for 12 × 75 mm tubes. Plate support covers 96-, 48-, and 24-well formats, so the modification is defined by its plate/tube handling rather than by any electrical or environmental rating in the verified facts.

Sample handling behavior

Sampling is defined by a 10 µL sample volume drawn at 66 µL/min, with one mix cycle of 10 s and one rinse cycle. The minimum sample volume and dead volume depend on the plate format: 96-well V- and U-bottom plates require 90 µL minimum with 50 µL dead volume; 48-well plates require 210 µL with 170 µL dead; 24-well plates require 310 µL with 270 µL dead. These values set the practical lower bound on well fill for reliable aspiration.

Installation and operation

The operator's guide covers hardware overview, installation, software control, sample acquisition, cleaning, and troubleshooting. Control is via software, and the unit is integrated with the NovoCyte cytometer. No electrical, environmental, or compliance specifications are given in the verified facts, so supply and site requirements must be taken from the full manual.

Integration & Operating Notes

Process Limits
Well fill must exceed dead volume plus sampling volume

For 96-well plates the dead volume is 50 µL and the minimum sample volume is 90 µL; for 48-well plates 170 µL dead and 210 µL minimum; for 24-well plates 270 µL dead and 310 µL minimum. Filling below the minimum risks aspirating air and losing the acquisition.

Factory Specification Sheet; NovoSampler Pro Operator's Guide
Process Limits
Only 12 × 75 mm tubes fit the 24-position rack

The operator's guide states that only the NovoSampler 24 tube rack for 12 × 75 mm tubes is supported. Other tube sizes cannot be loaded, so tube-based workflows must use this format or move to plate-based sampling.

NovoSampler Pro Operator's Guide, scope and variants
Control & I/O
Sampler is driven from the cytometer software

Mix cycles, rinse cycles, sampling volume, and flow rate are set through the software control described in the operator's guide. The sampler has no independent front-panel programming described in the verified facts.

NovoSampler Pro Operator's Guide, software control section
Maintenance
Run the rinse cycle and follow the cleaning procedure

The guide includes a cleaning section and defines one rinse cycle per acquisition. Carryover between samples is limited by that rinse; the cleaning procedure should be followed between runs and during troubleshooting.

NovoSampler Pro Operator's Guide, cleaning and troubleshooting

Selection & Integration Q&A

When should I choose the NovoSampler Pro rather than another sampler variant for my NovoCyte?

The verified facts list no sibling sampler variants, so selection is driven by format: choose it when you need 96-, 48-, or 24-well plate sampling or a 24-position 12 × 75 mm tube rack. If your workflow uses other tube sizes, this unit does not support them.

What must be true of the adjacent system for the sampler to work?

It is an accessory to the NovoCyte flow cytometer and is controlled through the cytometer software. The verified facts give no separate electrical or fluidic interface specification, so the cytometer connection and supply requirements must be confirmed in the full operator's guide before installation.

What maintenance and consumables are involved beyond the base unit?

The operator's guide defines a rinse cycle (one per acquisition) and a cleaning procedure for carryover and troubleshooting. The verified facts do not list cables, racks, or cleaning solutions as included, so rack and cleaning consumables should be ordered separately and the guide consulted for the schedule.