Avantik EM8
Avantik ·Made in USA · In Active Production

Avantik EM8

Avantik EM8 — Embedding centers.

The Avantik EM8 Embedding Center is a two-module system comprising the EM8H Dispensing Console and EM8C Cryo Console, designed for paraffin embedding in histology laboratories. The EM8H provides a 12 x 14.75 inch working area at 50–70 °C and a 5-liter paraffin reservoir, while the EM8C offers a cooling surface from 0 to -15 °C. This configuration supports sequential embedding workflows, from tissue orientation to block solidification.

Full specifications

Core Performance & Functional Specifications
Working area 12 x 14.75 inch
Working temperature 50-70 °C
Dimensions, Weight & Mechanical Design
Depth 17 inch
Height 26 inch
Weight 62 lbs
Width 23.25 inch

Description

Construction and Positioning

The EM8 is a modular embedding center consisting of two separate consoles: the EM8H Dispensing Console and the EM8C Cryo Console. The EM8H houses a 5-liter paraffin reservoir, left and right trays with 1.7-liter capacity each, and a heated working area maintained at 50–70 °C. The EM8C is a dedicated cooling unit with a working temperature range of 0 to -15 °C. This two-part architecture allows flexible bench placement and separation of heated and cold operations. The EM8H weighs 62 lbs and measures 23.25 x 17 x 26 inches (W x D x H), while the EM8C measures 13 x 16 x 23.75 inches and weighs 55 lbs. ### Operational Behavior

The heated working area of the EM8H provides a stable platform for tissue orientation and paraffin dispensing, with temperature adjustable between 50 and 70 °C to accommodate different paraffin formulations. The 5-liter reservoir supports extended embedding sessions without frequent refilling. The EM8C cryo console delivers a cooling surface from 0 down to -15 °C, enabling rapid solidification of paraffin blocks. The system is powered by a 100–240 V, 50/60 Hz supply, making it suitable for international laboratory environments. ### Installation and Control

Both consoles are designed for benchtop installation. The EM8H requires connection to a standard mains supply; no additional utilities are specified. The modular design allows independent placement of the dispensing and cryo units, optimizing workflow. Accessories include electric heated forceps (EQ6109, EQ6110, EQ6111) for precise manipulation of tissues and cassettes. No external controllers or software are mentioned; operation is via integrated controls on each console.

Integration & Operating Notes

Electrical
Dual-voltage supply simplifies global deployment

The EM8H accepts 100–240 V at 50/60 Hz, so the same unit can be used in most countries without a step-down transformer. Ensure the outlet is properly grounded and capable of supplying the console's full load; avoid sharing circuits with high-power equipment to prevent voltage fluctuations that could affect temperature stability.

Factory Specification Sheet
Process Limits
Paraffin reservoir must not be operated dry

The 5-liter reservoir is intended for molten paraffin only. Operating the heating element without sufficient paraffin can cause overheating and damage. Always maintain paraffin level above the minimum mark and never exceed the maximum fill line to prevent overflow when dispensing.

Instruction Manual, Section 3.2 Reservoir Operation
Mounting
Place consoles on a stable, level bench

The EM8H and EM8C are heavy units (62 lbs and 55 lbs respectively) and should be placed on a sturdy laboratory bench capable of supporting their weight. Ensure adequate clearance around the cryo console for ventilation and around the dispensing console for safe handling of hot paraffin.

Instruction Manual, Section 2.1 Site Requirements
Maintenance
Regular cleaning prevents paraffin buildup

Clean the working area and trays daily to prevent paraffin accumulation that can interfere with movement and temperature uniformity. Periodically inspect and clean the reservoir and dispenser nozzle. Refer to the manual for recommended cleaning agents and frequency.

Instruction Manual, Section 5.1 Cleaning and Maintenance

Selection & Integration Q&A

When should I choose the EM8 embedding center over a standalone heated unit or a different series?

Choose the EM8 when you need both heated dispensing and cryo cooling in one workflow. The EM8H provides a 5 L reservoir and 50–70 °C working area, while the EM8C offers 0 to -15 °C for rapid block solidification. If cooling is not required, a standalone heated unit may suffice.

What are the power and utility requirements for installing the EM8?

The EM8H requires a 100–240 V, 50/60 Hz supply. No other utilities (water, gas, compressed air) are specified. Ensure the outlet is grounded and can handle the console's load. The EM8C cooling unit is electrically powered as well; check the manual for its specific power draw.

What are the environmental and duty-cycle limits for the EM8?

Operate the EM8 in a clean, stable laboratory environment away from drafts. The heated working area is limited to 50–70 °C, and the cryo console to 0 to -15 °C. Continuous operation is possible, but ensure paraffin reservoir is not run dry and allow for periodic cleaning to maintain performance.

What maintenance and accessories are required for the EM8, and what is not included?

Regular cleaning of trays and reservoir is required. Accessories include electric heated forceps (EQ6109, EQ6110, EQ6111), which are not included in the base delivery. No other consumables are specified. Refer to the manual for detailed maintenance intervals and spare parts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Avantik-EM8-Embedding-Center-Sheet
Datasheet ·1,8 МБ ·2 pp.