Elmo Rietschle C-DLR 301
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle C-DLR 301

Elmo Rietschle C-DLR 301 — Claw Vacuum Pumps with Max inlet pressure 220 kPa, Motor power 22 kW, Pumping speed 320 m³/h.

The C-DLR 301 is a double-shaft, contact-free rotary claw compressor with dry compression chamber and oil-lubricated timing gears, driven by a flanged 18.5 kW (50 Hz) / 22 kW (60 Hz) motor. It delivers 270 m³/h at 50 Hz and 320 m³/h at 60 Hz, with a maximum inlet pressure of 2.2 bar, positioning it between the C-DLR 100 and C-DLR 401 in the series. It is intended for oil-free conveyance of non-aggressive, non-toxic dry gases and gas-air mixtures in industrial vacuum/pressure systems.

Max inlet pressure
220 kPa
Motor power
22 kW
Pumping speed
320 m³/h

Elmo Rietschle C-DLR Series — Model Comparison & Selection

Model Operating principleNoise level, dBWeight, kgLubrication typeMax inlet pressure, kPaMotor power, kW
C-DLR 301 Current claw80330—22022
C-DLR 100 Claw——dry——
C-DLR 401 —86510———

Full specifications

Core Performance & Functional Specifications
Max inlet pressure 2.2 bar (50 Hz)
60 Hz: 2.2 bar
Motor power 18.5 kW (50 Hz)
60 Hz: 22.0 kW
Operating principle claw
Pumping speed 270 m³/h (50 Hz)
60 Hz: 320 m³/h
Rotational speed 2950 rpm (50 Hz)
60 Hz: 3540 rpm
Dimensions, Weight & Mechanical Design
Weight 330 kg
Electrical, Power & Drive Specifications
Power supply 400 / 690 V ± 10 % (50 Hz)
60 Hz: 380 / 660 V ± 10 %
Materials, Media & Process Compatibility
Oil capacity 1.5 l
Operating Conditions, Environment & Protection
Noise level 80 dB (50 Hz)
60 Hz: 82 dB

Description

Construction and series positioning

Behaviour under load and media

Installation, connection and operation

Integration & Operating Notes

Mounting
Horizontal mounting with max. 8° inclination in all directions

The machine must be set up horizontally on a plane, even floor and secured against tipping and falling. Exceeding 8° inclination in any direction can impair lubrication and cause damage; ensure the floor or frame is level before commissioning.

Operating Instructions BA 887-EN, Chapter 5.2, page 18
Electrical
Check direction of rotation briefly before continuous operation

Start the motor briefly (max. two seconds) and verify that, when looking at the motor blower, it rotates counter-clockwise. Wrong direction of rotation may damage the machine. Use a phase sequence indicator. The machine may only be switched on again after it stands still.

Operating Instructions BA 887-EN, Chapter 6.1.2, page 22
Process Limits
Ambient and inlet temperature must stay between 5 and 40 °C

Operation outside this range requires consultation with the manufacturer. Ensure installation room ventilation and cooling air supply are adequate. Above 1000 m above sea level, a noticeable power reduction occurs; contact the manufacturer for high-altitude installations.

Operating Instructions BA 887-EN, Chapter 2.4, page 8; Chapter 5.2, page 18

Selection & Integration Q&A

When should I choose the C-DLR 301 instead of the C-DLR 100 or C-DLR 401?

Choose the C-DLR 301 when your required flow is around 270–320 m³/h and inlet pressure up to 2.2 bar. The C-DLR 100 is smaller and suited to lower flows; the C-DLR 401 is larger for higher flows. The 301 balances capacity and footprint for medium-duty dry gas handling.

What are the requirements for the suction and discharge piping connected to the C-DLR 301?

Use flexible connections (compensators) on both suction and discharge sides. Install an external inlet screen with approx. 0.05 mm filter on the suction side. Avoid vertical exhaust lines on the discharge side due to condensation risk. For lines longer than 3 m, a non-return valve (ZRK) is recommended to prevent reverse running after shutdown.

What are the mounting and duty-cycle limits for the C-DLR 301?

Mount horizontally with max. 8° inclination in all directions. Keep 30 cm clearance for cooling air and 40 cm for maintenance. Ambient/inlet temperature must be 5–40 °C. Frequent switching (approx. 10 times per hour) or high temperatures may exceed motor winding and bearing limits; consult the manufacturer for such duty.

What maintenance items and accessories are not included in the base delivery but are required?

The base delivery does not include a motor protection switch (must be provided by the operator), an external inlet screen with approx. 0.05 mm filter, compensators, or a non-return valve (ZRK) for long lines. Spare parts are ordered per list E 887. Oil (ISO-VG 150, e.g. GEAR-LUBE 150) must be specified separately. The safety valve is included as standard and is mandatory for operation; it is a wear part and should be replaced according to the maintenance schedule.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — C-DLR 301 compressor (BA 887-EN, ed. 2.0 20/01/2023, EN)
Manual ·2,2 МБ ·36 pp.
View PDF
PDF
Operating Instructions — C-DLR 301 ATEX compressor (BA 887-21-DE, DE)
Manual ·951,2 КБ ·28 pp.
View PDF
PDF
Technical Data Sheet — C-DLR 301 IE3 compressor DE/EN)
Datasheet ·813,2 КБ ·4 pp.
View PDF
PDF
Spare Parts List — C-DLR 301 (E 887, EN)
Spare parts ·314,2 КБ ·2 pp.
View PDF