Elmo Rietschle C-KLR 80
Elmo Rietschle C-KLR 80 — Claw Vacuum Pumps with Motor power 4.8 kW, Pumping speed 120 m³/h.
The C-KLR 80 is a dry, contact-free claw vacuum pump with a 4.0/4.8 kW IE3 motor, delivering 94/120 m³/h at 50/60 Hz. As the smaller of two C-KLR series models, it uses G 1 1/4 ports and 0.55 l oil, distinguishing it from the C-KLR 140. It is suited for oil-free evacuation or pressure duty in non-explosive, non-aggressive gas systems.
Full specifications
| Lubrication type | dry |
| Motor power | 4.0 kW (50 Hz) 60 Hz: 4.8 kW |
| Operating principle | claw (contact-free, dry compression) |
| Pumping speed | 94 m3/h (50 Hz) 60 Hz: 120 m3/h |
| Rotational speed | 2900 min-1 (50 Hz) |
| Height | 415 mm |
| Length | 791 mm |
| Weight | 136 kg |
| Width | 387 mm |
| Power supply | 230 / 400 V ± 10 % (50 Hz) 3~: AC |
| Inlet flange | G 1 1/4 |
| Outlet flange | G 1 1/4 |
| Oil capacity | 0.55 l |
| Noise level | 79 dB(A) (50 Hz) 60 Hz: 88 dB(A) |
| Protection rating | IP 55 |
| Cooling type | air |
| Sound pressure level (max.) (alt 50 Hz) mfr | 83 dB(A) (50 Hz) |
Description
Construction and series positioning
- The C-KLR 80 is a double-shaft, contact-free claw pump; compression is dry, with no sealing fluid in the working chamber. Lubrication is confined to the bearing/gear oil sump (0.55 l).
- Within the C-KLR series, it is the lower-capacity model: nominal flow 94 m³/h at 50 Hz and 120 m³/h at 60 Hz, versus the C-KLR 140. Ports are G 1 1/4 (vacuum and pressure), whereas the C-KLR 140 uses G 1 1/2. Weight is 136 kg.
- The motor is an IE3 AC machine rated 4.0 kW at 50 Hz and 4.8 kW at 60 Hz, with 2900 min⁻¹ at 50 Hz. Protection is IP 55, insulation class F, compliant with DIN EN 60034.
Behavior under load and media
- Permissible media are non-explosive, non-inflammable, non-aggressive and non-poisonous dry gases and gas-air mixtures. Water vapour, liquids, solids, solvents and oxidants are excluded.
- Load limits on the intake and pressure sides are stated on the data plate; flow-rate dependency on excess pressure is given in data sheet D 883. No digitized curve points are available in the supplied facts.
- Ambient and suction temperature must remain between 5 and 40 °C. Frequent switching above about 12 times/h, or elevated ambient/intake temperatures, may exceed motor winding and bearing temperature limits and requires manufacturer consultation.
- At altitudes above 1000 m, a noticeable reduction in power occurs; consult the manufacturer for high-altitude installations.
Installation, connection and operation
- Cooling is by air; cooling-air inlets and outlets must be at least 20 cm from adjacent walls, and at least 40 cm clearance is required in front of inlet filters for maintenance.
- Pipe connections must match G 1 1/4. If connection pipes of the same cross-section are longer than 3 m, a non-return valve must be installed to prevent reverse operation after stop.
- Electrical supply is 3~ 230/400 V ±10 % at 50 Hz. Without derating, voltage deviation is limited to ±5 % and frequency deviation to ±2 %. A motor protection switch is required, and electrical installation must be by a qualified electrician per EN 60204.
- Oil must be ISO VG 150 per DIN 51519 (CLP HC 150; e.g. GEARLUBE 150). Fill to the middle of the sight glass; overfilling or underfilling affects lubrication.
Integration & Operating Notes
The pump is restricted to non-explosive, non-inflammable, non-aggressive and non-poisonous dry gases and gas-air mixtures. Water vapour, liquids, solids, solvents, gaseous oxygen and other oxidants must be excluded; dust per ATEX zone 20–22 is not permitted. Selection must confirm the process gas is compatible to avoid corrosion or hazardous reaction.
Cooling-air inlets and outlets must be at least 20 cm from adjacent walls to prevent recirculation of heated air. A minimum of 40 cm in front of the inlet filters is required for maintenance access. The foundation and lifting device must be sized for the 136 kg weight.
When connection pipes of the same cross-section as the machine connection are longer than 3 m, a non-return valve must be installed. This prevents reverse operation when the machine has stopped. Pipe routing must account for this length threshold and the G 1 1/4 port size.
Without derating, voltage deviation is limited to ±5 % and frequency deviation to ±2 % from the motor data plate. The supply is 3~ 230/400 V ±10 % at 50 Hz, but the tighter ±5 % applies for full performance. A motor protection switch is required, and installation must follow EN 60204 by a qualified electrician.
Oil must be ISO VG 150 per DIN 51519 (CLP HC 150; e.g. GEARLUBE 150). The oil change interval is every 5,000 operating hours under clean conditions. Check the oil level monthly and fill to the middle of the sight glass. If changing oil type, empty the oil tank completely first.
Filter cartridges should be replaced every six months; cleaning by blowing through from the inside out is possible depending on dirt. Insufficient air filter maintenance reduces power and may damage the machine. Coupling sprockets must be checked at least once a year; defective sprockets may lead to rotor shaft breakage.
Frequent switching at about 12 times/h or higher, or elevated ambient/intake temperatures, may exceed motor winding and bearing temperature limits. Contact the manufacturer if the unit is used under such conditions. Ambient and suction temperature must remain between 5 and 40 °C.
At more than 1000 m above sea level a reduction in power is noticeable. Contact the manufacturer for high-altitude installations to confirm suitability or necessary derating.
Selection & Integration Q&A
Choose the C-KLR 80 for flows up to 94 m³/h at 50 Hz (120 m³/h at 60 Hz) with G 1 1/4 ports. The C-KLR 140 offers higher flow and G 1 1/2 ports but weighs 170 kg. Select the 80 when its capacity and port size match the system, avoiding oversizing.
Pipes must match G 1 1/4. If connection pipes of the same cross-section are longer than 3 m, a non-return valve must be installed to prevent reverse operation after stop. Ensure the valve is compatible with the dry, non-aggressive gas duty.
Ambient and suction temperature must be 5–40 °C. Provide 20 cm clearance around cooling-air openings and 40 cm in front of filters. Limit switching to about 12 times/h; higher rates or temperatures may exceed motor limits and require consultation.
Plan for oil changes every 5,000 h using ISO VG 150 oil (0.55 l), filter cartridge replacement every 6 months, and annual coupling sprocket inspection. Oil, filters, and coupling sprockets are not included in base delivery and must be ordered separately.