The V-DTN is a side-channel blower configured as a compressor, delivering 17.0 m³/h at 50 Hz and 20.5 m³/h at 60 Hz with a maximum differential pressure of 0.7 mbar (50 Hz) or 0.6 mbar (60 Hz). It is distinguished within the series by its size-specific connections (Rp 1/2 for V-DTN 16/26, Rp 3/4 for V-DTN 41) and compact footprint. It serves as a low-pressure air source in central vacuum or pressure systems requiring oil-free, pulsation-free flow.

Max differential pressure
0.6 mbar
Noise level
63 dB
Pumping speed
20.5 m³/h
Weight
29 kg

Full specifications

Core Performance & Functional Specifications
Max differential pressure 0.7 mbar (50 Hz)
60 Hz: 0.6 mbar
Noise level 61 dB (50 Hz)
60 Hz: 63 dB
Pumping speed 17.0 m³/hour (50 Hz)
60 Hz: 20.5 m³/hour
Suction connection mfr Rp 1/2 (V-DTN 16)
Suction connection mfr Rp 1/2 (V-DTN 26)
Suction connection mfr Rp 3/4 (V-DTN 41)
Pressure connection mfr Rp 1/2 (V-DTN 16)
Pressure connection mfr Rp 1/2 (V-DTN 26)
Pressure connection mfr Rp 3/4 (V-DTN 41)
Volumenstrom / Volume flow mfr 17,0 m3/h (50 Hz)
Volumenstrom / Volume flow mfr 20,5 m3/h (60 Hz)
Überdruck / Overpressure mfr 1,0 bar (50 Hz)
Überdruck / Overpressure mfr 1,0 bar (60 Hz)
a1 mfr 30 mm
b mfr 254 mm
b1 mfr 236 mm
c mfr 283 mm
e mfr 180 mm
f mfr 220 mm
l mfr 125 mm
l2 mfr 65 mm
m mfr 79 mm
n mfr 126 mm
o mfr 150 mm
p mfr 170 mm
r mfr 164 mm
r1 mfr 11 mm
v mfr 246 mm
v2 mfr 14 mm
R1 mfr Rp 1/2
Überdruck (alt 50 Hz) mfr 1,0 mbar (50 Hz)
Overpressure (alt 60 Hz) mfr 1,0 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 29 kg (3~)
1~: 29 kg
Dimension a1 mfr 30 mm (V-DTN 16)
Dimension a1 mfr 33 mm (V-DTN 26)
Dimension a1 mfr 42 mm (V-DTN 41)
Dimension b mfr 254 mm (V-DTN 16)
Dimension b mfr 254 mm (V-DTN 26)
Dimension b mfr 275 mm (V-DTN 41)
Dimension b1 mfr 236 mm (V-DTN 16)
Dimension b1 mfr 236 mm (V-DTN 26)
Dimension b1 mfr 270 mm (V-DTN 41)
Dimension c mfr 283 mm (V-DTN 16)
Dimension c mfr 283 mm (V-DTN 26)
Dimension c mfr 319 mm (V-DTN 41)
Dimension e mfr 180 mm (V-DTN 16)
Dimension e mfr 180 mm (V-DTN 26)
Dimension e mfr 200 mm (V-DTN 41)
Dimension f mfr 220 mm (V-DTN 16)
Dimension f mfr 220 mm (V-DTN 26)
Dimension f mfr 242 mm (V-DTN 41)
Dimension l mfr 125 mm (V-DTN 16)
Dimension l mfr 125 mm (V-DTN 26)
Dimension l mfr 147 mm (V-DTN 41)
Dimension l2 mfr 65 mm (V-DTN 16)
Dimension l2 mfr 65 mm (V-DTN 26)
Dimension l2 mfr 72 mm (V-DTN 41)
Dimension m mfr 79 mm (V-DTN 16)
Dimension m mfr 79 mm (V-DTN 26)
Dimension m mfr 90 mm (V-DTN 41)
Dimension n mfr 126 mm (V-DTN 16)
Dimension n mfr 161 mm (V-DTN 26)
Dimension n mfr 175 mm (V-DTN 41)
Dimension o mfr 150 mm (V-DTN 16)
Dimension o mfr 150 mm (V-DTN 26)
Dimension o mfr 190 mm (V-DTN 41)
Dimension p mfr 170 mm (V-DTN 16)
Dimension p mfr 170 mm (V-DTN 26)
Dimension p mfr 210 mm (V-DTN 41)
Dimension r mfr 164 mm (V-DTN 16)
Dimension r mfr 164 mm (V-DTN 26)
Dimension r mfr 201 mm (V-DTN 41)
Dimension r1 mfr 11 mm (V-DTN 16)
Dimension r1 mfr 11 mm (V-DTN 26)
Dimension r1 mfr 10 mm (V-DTN 41)
Dimension v mfr 246 mm (V-DTN 16)
Dimension v mfr 246 mm (V-DTN 26)
Dimension v mfr 282 mm (V-DTN 41)
Dimension v2 mfr 14 mm (V-DTN 16)
Dimension v2 mfr 14 mm (V-DTN 26)
Dimension v2 mfr 8 mm (V-DTN 41)
Standards, Safety & General Data
Average noise level (EN ISO 3744) mfr 61 dB (50 Hz)
Average noise level (EN ISO 3744) mfr 63 dB (60 Hz)

Description

Construction and series positioning

The V-DTN is a side-channel (regenerative) blower from Elmo Rietschle, available in sizes 16, 26, and 41. This model code covers the base configuration with either 3~ IE3 motors (GX, GA, GB, GD, GE) or 1~ motors, for 50 Hz or 60 Hz operation. The suction and pressure connections are Rp 1/2 for sizes 16 and 26, and Rp 3/4 for size 41. Overall dimensions vary by size: dimension b is 254 mm for 16/26 and 275 mm for 41; dimension c is 283 mm for 16/26 and 319 mm for 41. Weight is 29 kg for both 3~ and 1~ variants.

Performance and operating behavior

At 50 Hz, the V-DTN delivers 17.0 m³/h pumping speed and a maximum differential pressure of 0.7 mbar; at 60 Hz, these are 20.5 m³/h and 0.6 mbar. Noise level is 61 dB at 50 Hz and 63 dB at 60 Hz. The side-channel principle provides oil-free, pulsation-free air flow, making it suitable for continuous duty in central vacuum or pressure systems. No digitized curve points are available; refer to the technical data sheet for detailed performance curves.

Installation and connections

Mounting dimensions are provided per size: for V-DTN 16/26, dimension a1 is 30/33 mm, b1 is 236 mm, e is 180 mm, f is 220 mm, l is 125 mm, and l2 is 65 mm; for V-DTN 41, a1 is 42 mm, b1 is 270 mm, e is 200 mm, f is 242 mm, l is 147 mm, and l2 is 72 mm. The blower can be installed in any orientation, but ensure sufficient clearance for motor cooling. Electrical connection must match the motor variant: 3~ IE3 motors require a suitable starter with overload protection; 1~ motors are supplied with capacitor and require a dedicated circuit. Control and I/O are not integrated; external contactors or variable frequency drives (for 3~) must be provided by the installer.

Integration & Operating Notes

Mounting
Secure mounting to avoid vibration and noise

The blower must be bolted down using all four mounting points to a rigid, flat surface. Excessive vibration from improper mounting can lead to bearing damage and increased noise. Use anti-vibration mounts if the structure is flexible.

Technical Data Sheet — compressor DE/EN
Electrical
Motor protection required for 3~ variants

3~ IE3 motors must be connected via a contactor with thermal overload protection set to the motor's full-load current. For 1~ motors, ensure the capacitor is correctly wired and protected. Incorrect protection can void warranty and cause motor burnout.

Technical Data Sheet — compressor DE/EN
Maintenance
Regular cleaning of suction filter extends service life

If a suction filter is fitted, inspect and clean it periodically; a clogged filter reduces performance and can cause overheating. Replace the filter if damaged. Refer to the spare parts list for filter part numbers specific to V-DTN 16 and V-DTN 26; for V-DTN 41, consult the spare parts list for the applicable filter part number.

Spare Parts List — E381
Control & I/O
No integrated controls; external starter required

The V-DTN is a bare-shaft blower without built-in control electronics. The installer must provide motor starting equipment, overload protection, and any required sensors or switches for system integration.

Technical Data Sheet — compressor DE/EN

Selection & Integration Q&A

When should I choose the V-DTN over other sizes in the series?

Choose V-DTN 16 or 26 for Rp 1/2 connections; V-DTN 41 offers Rp 3/4 connections. The published pumping speed of 17.0 m³/h at 50 Hz and 20.5 m³/h at 60 Hz applies to the V-DTN series; size-specific flow figures are not provided in the verified data. Select based on required connection size and confirm performance from the technical data sheet.

What are the requirements for the electrical supply and motor protection?

For 3~ IE3 motors, provide a contactor with thermal overload protection set to motor FLC. For 1~ motors, ensure correct capacitor wiring and dedicated circuit. Supply voltage must match motor nameplate (e.g., 230/400 V or 230/460 V).

What maintenance items and accessories are not included in the base delivery?

The base delivery excludes suction filter, pressure relief valve, and motor starter. Spare parts such as filters and gaskets are listed in the Spare Parts List E381. If a suction filter is fitted, regular cleaning is recommended.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — compressor DE/EN)
Datasheet ·407,1 КБ ·4 pp.
View PDF
PDF
Spare Parts List — E381 (E381, ed. 2.1 27.10.2022, EN)
Spare parts ·1,1 МБ ·8 pp.
View PDF