Elmo Rietschle V-VCA — Central Industrial & Medical Vacuum Systems with Motor power 0.9 kW, Noise level 59 dB, Pumping speed 30 m³/h.

The V-VCA 25 is a single-stage oil-flooded rotary vane vacuum pump with G3/4 inlet and G1/2 outlet, air-cooled and close-coupled to a 0.75 kW (50 Hz) / 0.9 kW (60 Hz) flange motor. It delivers 25 m³/h at 50 Hz and 30 m³/h at 60 Hz with an ultimate pressure of 0.5 mbar, and is the fine-vacuum member of the V Series, distinguished from the V-VCE 25 by its continuous intake range of 0.5–130 mbar (abs.) at 50 Hz. It is intended for continuous fine-vacuum duty in central industrial vacuum systems, evacuating closed volumes no larger than 2 % of nominal pumping capacity.

Motor power
0.9 kW
Noise level
59 dB
Pumping speed
30 m³/h
Ultimate pressure
0.5 mbar
Weight
22 kg

Full specifications

Core Performance & Functional Specifications
Motor power 0.75 kW (50 Hz)
60 Hz: 0.9 kW
Noise level 57 dB (50 Hz)
60 Hz: 59 dB
Pumping speed 25 m³/hour (50 Hz)
60 Hz: 30 m³/hour
Ultimate pressure 0.5 mbar
Rotational speed 1420 rpm (50 Hz)
60 Hz: 1720 rpm
Nominal suction capacity mfr 25 m3/h (50 Hz)
Nominal suction capacity mfr 30 m3/h (60 Hz)
Intake pressure range mfr 0,5 – 130 mbar (abs.) (50 Hz)
Intake pressure range mfr 0,5 – 100 mbar (abs.) (60 Hz)
Motor version mfr UA IE3
Motor speed mfr 1720 min-1 (60 Hz)
Nennsaugvermögen / Nominal suction capacity mfr 25 m3/h (50 Hz)
Nennsaugvermögen / Nominal suction capacity mfr 30 m3/h (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 22 kg
GA IE3: 13.5 kg
Length 466 mm
Max. weight without motor mfr 22 kg
Motor weight mfr 15.0 kg
max. weight ohne Motor / max. Weight without motor mfr 22 kg
Electrical, Power & Drive Specifications
Current 2.82 / 1.62 A (50 Hz)
60 Hz: 2.90 / 1.67 A
Voltage 230 / 400 V (50 Hz)
60 Hz: 265 / 460 V
Motor voltage mfr 330 | 380 / 660 V ± 10 % (50 Hz)
Motor current mfr 1.96 | 1.71 / 0.982 A (50 Hz)
Motor voltage mfr 220 / 380 | 440 V ± 10 % (60 Hz)
Motor current mfr 3.49 / 2.02 | 1.75 A (60 Hz)
Motor voltage GA IE3 mfr 230 / 400 V ± 10 % (50 Hz)
Motor voltage GA IE3 mfr 265 / 460 V ± 10 % (60 Hz)
Motor speed GA IE3 mfr 1420 min-1 (50 Hz)
Motor speed GA IE3 mfr 1720 min-1 (60 Hz)
Motor current GA IE3 mfr 2,82 / 1,62 A (50 Hz)
Motor current GA IE3 mfr 2,90 / 1,67 A (60 Hz)
Motor voltage UA IE3 mfr 330|380 / 660 V ± 10 % (50 Hz)
Motor voltage UA IE3 mfr 220 / 380|440 V ± 10 % (60 Hz)
Motor current UA IE3 mfr 1,96|1,71 / 0,982 A (50 Hz)
Motor current UA IE3 mfr 3,49 / 2,02|1,75 A (60 Hz)
Motor weight UA IE3 mfr 15,0 kg
Interfaces, Connections & Control
Inlet connection G3/4
Outlet connection G1/2
Materials, Media & Process Compatibility
Oil capacity mfr 1.0 l
Öleinfüllmenge / Oil capacity mfr 1,0 l
Operating Conditions, Environment & Protection
Cooling type Air cooling
Average noise level mfr 59 dB(A) (60 Hz)
Standards, Safety & General Data
Ultimate vacuum (standard) mfr 0.5 mbar (abs.)
Enddruck (Standard) / Ultimate vacuum (standard) mfr 0,5 mbar (abs.)
Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr 57 dB(A) (50 Hz)
Mittlerer Schalldruckpegel / Average noise level (EN ISO 3744) mfr 59 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Continuous intake must stay within 0.5–130 mbar (abs.) at 50 Hz

Operating the V-VCA 25 continuously outside its fine-vacuum intake range risks oil leakage through the outlet. At 60 Hz the upper limit drops to 100 mbar (abs.). Size the process so the pump does not run continuously in rough-vacuum conditions; for rough vacuum duty the V-VCE 25 is the correct series member.

Operating Instructions BA 150-3-EN, Chapter 4.4 / p.16
Process Limits
Closed volumes to be evacuated limited to 2 % of pumping capacity per hour

When evacuating closed systems, the volume to be evacuated must be no more than 2 % of the nominal pumping capacity per hour. With 25 m³/h at 50 Hz this corresponds to a maximum closed volume of 0.5 m³; at 30 m³/h (60 Hz) the limit is 0.6 m³. Larger volumes require a different sizing approach or pump selection to avoid operating outside the intended use.

Operating Instructions BA 150-3-EN, Chapter 4.4 / p.16
Process Limits
Exhaust back pressure must not exceed +100 mbar

Exhaust lines must be sized and routed so that back pressure stays below +100 mbar. No filter may be installed on the exhaust air side. Excessive back pressure affects operation and can force oil out through the outlet.

Operating Instructions BA 150-3-EN, Chapter 2.4, 5.3 / p.8, p.18
Mounting
Horizontal setup with max. 1° inclination in all directions

The machine may only be operated set up horizontally with a maximum inclination of 1° in all directions. Mount on a plane, even floor able to carry the machine weight and secure it against tipping and falling; a tilted installation compromises oil circulation and lubrication.

Operating Instructions BA 150-3-EN, Chapter 5.2 / p.17
Cooling & Media
Keep 20 cm clearance for cooling air and 40 cm for maintenance

Cooling air inlets and outlets must be at least 20 cm away from adjacent walls to prevent recirculation of hot cooling air and overheating. Provide at least 40 cm space around the machine for access to filter housing, oil filling point, oil sight glass, oil drain, gas ballast and oil separator housing.

Operating Instructions BA 150-3-EN, Chapter 5.1, 5.2 / p.17
Electrical
Verify clockwise rotation before continuous operation

Looking at the motor fan, the motor must rotate clockwise; check with a phase sequence indicator (anti-clockwise rotating field). Reverse rotation can draw in media and damage the machine, so the check must be completed before the pump is released for continuous duty.

Operating Instructions BA 150-3-EN, Chapter 6.1.2 / p.21
Maintenance
Top up oil after the first 2 minutes of running, then check daily

After first start, stop the motor after 2 minutes and top oil up to the upper edge of the sight glass; repeat until all oil pipes are filled. The filling point must not be open while the pump is running. Thereafter check the oil level every day; low oil level can damage the pump, and visible oil mist in the exhaust air or leaks must be investigated immediately.

Operating Instructions BA 150-3-EN, Chapter 6.1.2, 6.2.1 / p.21, p.22
Maintenance
Use only ISO VG 100 oil

Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448; the oil capacity is 1.0 l. Incorrect viscosity can cause overheating, insufficient pumping capacity or motor protection trips. The maintenance table in Chapter 7 covers oil change, oil separator insert, air filter cleaning and motor/coupling checks.

Operating Instructions BA 150-3-EN, Chapter 7 / p.23

Selection & Integration Q&A

When should I choose the V-VCA 25 rather than the V-VCE 25 of the same series?

Pick the V-VCA 25 for fine-vacuum duty: continuous intake 0.5–130 mbar (abs.) at 50 Hz (0.5–100 mbar at 60 Hz), ultimate 0.5 mbar. Choose the V-VCE 25 for rough vacuum, 10–500 mbar (abs.) at 50 Hz. Both share identical construction and differ only in achievable vacuum.

What must I check on the motor supply and protection before commissioning this pump?

Verify the motor data plate against the mains; unless stated otherwise, tolerances are ±5 % voltage and ±2 % frequency. Motors are IP 55, insulation class F per DIN EN 60034, so fit an appropriate motor protection switch. Confirm clockwise rotation at the motor fan with a phase sequence indicator before continuous operation. The electrical data in the specification table apply to the UA IE3 motor; confirm the actual motor variant (UA/GA/TA IE3) against the data plate.

What mounting and duty-cycle limits apply to the V-VCA 25 installation?

Operate only horizontally with max. 1° inclination in all directions on a floor able to carry the weight, secured against tipping. Keep 20 cm clearance at cooling-air inlets/outlets and 40 cm around the machine for maintenance. Ambient and inlet temperature 5–40 °C; above 1000 m altitude output drops noticeably.

What maintenance items and consumables are needed beyond the base pump delivery?

Plan for ISO VG 100 oil per DIN ISO 3448 (1.0 l capacity), topped up after the first 2 minutes of running and checked daily. The maintenance table also covers air filter cleaning, oil separator insert and oil change. Exhaust-side filters are not permitted; back pressure must stay below +100 mbar.