Elmo Rietschle V-VCS 200
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle V-VCS 200

Elmo Rietschle V-VCS 200 — Central Industrial & Medical Vacuum Systems.

The V-VCS 200 is a single-stage, oil-flooded rotary vane vacuum pump with a nominal suction capacity of 200 m³/h at 50 Hz, configured for continuous intake pressures from 0.5 to 500 mbar (abs.). Within the V-VCS series, it sits between the V-VCS 100 and V-VCS 400, using the same standard (non-VCX) design without enhanced water-vapour resistance. It serves as the vacuum-generating unit in central industrial vacuum systems, where its 200 m³/h displacement matches the required pumping speed at process pressure.

Elmo Rietschle V-VCS Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBPumping speed, m³/hUltimate pressure, mbarWeight, kgCurrent, A
V-VCS 200 Current ——————
V-VCS 100 ——————
V-VCS 1100 258126180742.9–74.5
V-VCS 40 1.163480.5392.34–4.07
V-VCS 400 9734000.535710.5–18.1

Full specifications

Core Performance & Functional Specifications
Model mfr V-VCS 200
Series mfr V Series
Design mfr Rotary Vane
Document type mfr Operating Instructions (Translation of the origi
Edition mfr 1.7
Date mfr 28/06/2022
Document number mfr BA 236-EN
Max inclination mfr 1 °
Maintenance clearance mfr 50 cm
Max. inclination mfr 1 ° (in all directions)
Maintenance clearance around machine mfr 50 cm (minimum)
Operating Conditions, Environment & Protection
Ambient temperature limit 12 degC (min.)
max.: 40 degC
Cooling type Air-cooled (cooling air inlets/outlets, min. 30 cm from walls)
Cooling air clearance to walls mfr 30 cm

Description

Construction and series positioning

Behaviour under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Intake pressure must stay within 0.5–500 mbar (abs.)

Operating the V-VCS 200 outside its continuous intake pressure range risks oil being carried through the outlet opening. Processes that periodically drop below 0.5 mbar or rise above 500 mbar require a different pump size or the V-VCX variant, and the suction line must be vented to atmosphere for standstill periods longer than two minutes.

Operating Instructions BA 236-EN, Section 4.4, page 16; Section 2.5, page 8
Process Limits
Closed-system volume limited to 2% of pumping capacity

When evacuating a closed system, the volume to be evacuated must not exceed 2% of the nominal pumping capacity — approximately 4 m³ for the 200 m³/h V-VCS 200. Larger volumes require either a larger pump from the series or staged evacuation, otherwise evacuation time and oil carry-over behaviour become unpredictable.

Operating Instructions BA 236-EN, Section 4.4, page 16
Process Limits
Above 100 mbar continuous, specify the next higher motor output

For continuous operation at intake pressures above 100 mbar (abs.), the next higher motor output must be used to prevent motor overheating. System designers should confirm the actual duty-point pressure before ordering, because the standard motor supplied with the V-VCS 200 is intended for lower continuous intake pressures.

Operating Instructions BA 236-EN, Section 4.4, page 16
Process Limits
Exhaust back pressure must not exceed +100 mbar

The permissible back pressure on the exhaust air side is up to +100 mbar, and no filters may be installed on the exhaust side. Exhaust piping must be sized so that this limit is never exceeded during operation, since higher back pressure can damage the pump and distort vacuum performance.

Operating Instructions BA 236-EN, Section 5.3, page 18; Section 2.5, page 8
Control & I/O
Parallel pumps need an external non-return valve per suction line

When several pumps operate in parallel, an external non-return valve must be installed in the suction line upstream of each pump. This prevents a switched-off V-VCS 200 from being driven backwards by the operating pumps, which would damage the pump and contaminate the oil.

Operating Instructions BA 236-EN, Section 5.3, page 18
Control & I/O
Vent the suction line to atmosphere during standstill > 2 min

For standstill times longer than two minutes, the connected suction line must be vented to atmospheric pressure. Provide an air-release position such as a ball valve in the suction line so that the pump does not start against vacuum and oil is not drawn into the suction line during idle periods.

Operating Instructions BA 236-EN, Section 5.3, page 18
Maintenance
Use only ISO VG 100 lubricating oil and observe storage limits

Lubricating oil must comply with ISO VG 100 as per DIN ISO 3448; incorrect viscosity can cause overheating or insufficient vacuum. Storage is limited to 6 months at -10 to +60 °C and max. 80% relative humidity, and storage beyond 3 months requires preservation oil instead of operating oil.

Operating Instructions BA 236-EN, Section 7.6, page 26; Section 8.1, pages 33-34; Section 3.2.1, page 13
Environment
Ambient and inlet temperature must stay between 12 and 40 °C

Both ambient temperature and inlet temperature must remain within 12 to 40 °C; the manufacturer must be contacted for operation outside this range. Output reduction is noticeable above 1000 m above sea level, so high-altitude installations require consultation before selection.

Operating Instructions BA 236-EN, Section 2.4, page 8; Section 5.2, page 17

Selection & Integration Q&A

When should I choose the V-VCS 200 rather than the V-VCX 200 or another V-VCS size?

Pick the V-VCS 200 when the duty point is near 200 m³/h at 50 Hz and the process is dry or only mildly humid, with intake pressure between 0.5 and 500 mbar (abs.). Choose the V-VCX 200 if the gas stream carries water vapour or solvents, since it adds resistant internals and an adjustable gas ballast. Move to V-VCS 100 or 400 only if the required pumping speed falls clearly below or above 200 m³/h.

What must be provided on the suction and exhaust side when integrating this pump into a central vacuum system?

The suction line needs an air-release valve for standstill venting and, in parallel-pump installations, an external non-return valve upstream of each pump. The exhaust line must be sized so back pressure never exceeds +100 mbar and must not carry filters. The evacuated closed volume should not exceed 2% of the 200 m³/h capacity (about 4 m³).

What mounting and duty-cycle limits apply to the V-VCS 200 in a plant room?

Mount horizontally with max. 1° inclination on a plane, even surface, keeping 30 cm clearance around cooling air inlets/outlets and 50 cm free space for maintenance. Ambient and inlet temperatures must stay between 12 and 40 °C. Avoid switching frequencies around 10 times per hour or higher temperatures without consulting the manufacturer, as motor winding and bearing limits may be exceeded.

What maintenance items and consumables are needed, and what is not included in the base delivery?

The base pump does not include lubricating oil, suction-line vent valve, external non-return valves, or exhaust piping. Maintenance requires ISO VG 100 oil per DIN ISO 3448, oil separator element replacement, filter cleaning, and oil cooler/fan checks per the maintenance table. For storage beyond 3 months, preservation oil must be used instead of operating oil.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — VCS 200 vacuum pump (BA 236-EN, ed. 1.7 28/06/2022, EN)
Manual ·2,5 МБ ·38 pp.
View PDF