Eppendorf BioFlo ® 120
Eppendorf ·Made in Germany · In Active Production

Eppendorf BioFlo ® 120

Eppendorf BioFlo ® 120 — Bioreactors & fermenters.

Single-unit bioreactor controller for glass and single-use vessels, accepting autoclavable 1–10 L and BioBLU single-use vessels up to 50 L. It supports bacteria, yeast, fungi, insect, mammalian and stem-cell cultures with up to 20 SLPM gas flow and a 7-inch interface. It serves as the benchtop control hub for parallel-free, scalable bioprocess development.

Full specifications

Core Performance & Functional Specifications
Bacteria/yeast/fungi yes
Communication 2
Exhaust Condensation Water-cooled or Electric heater band
Gas Supply 1
Insect yes
Interchangeable Vessels yes
Mammalian/animal yes
Stem Cells yes
Validatable no
Vessels Glass/single-use vessels
Number of parallel units mfr Single unit
Dimensions (W × D × H) mfr 24,7 × 55,9 × 62,9 cm / 9,7 × 22,0 × 24,8 in
Water supply mfr Quick-connect; 10 psig (0.69 barg)
Max. gas flow rates mfr 20 SLPM
Dimensions, Weight & Mechanical Design
Product Weight 14.8 kg
Electrical, Power & Drive Specifications
Power supply mfr 100 – 120/208 – 240 V ±10 %, 50/60 Hz
Power supply mfr IEC-C14 (with regional plug types); 100 – 120/20
Interfaces, Connections & Control
User Interface 7

Description

Construction and positioning

Behavior and media

Installation and operation

Integration & Operating Notes

Cooling & Media
Provide 10 psig water at a quick-connect for exhaust condensation

Exhaust condensation uses either a water-cooled condenser or an electric heater band. When the water-cooled option is fitted, the supply must be connected by quick-connect at 10 psig (0.69 barg); insufficient pressure or flow will compromise condenser performance and exhaust handling.

Factory Specification Sheet, Water supply; Brochure BioFlo 120
Process Limits
Keep total gas demand within the 20 SLPM ceiling

Maximum gas flow rates reach 20 SLPM from a single gas supply. When specifying spargers, mass flow controllers or overlay lines, sum all gas consumers against this ceiling; exceeding it will starve at least one gas path and invalidate the intended aeration strategy.

Factory Specification Sheet, Max. gas flow rates
Control & I/O
Two communication interfaces and a 7-inch local interface

The controller exposes two communication interfaces alongside the 7-inch user interface. Plan supervisory control or data logging around these two ports; the supplied facts do not specify protocol or connector type, so confirm compatibility with the site's SCADA or DAS before purchase.

Factory Specification Sheet, Communication; User interface

Selection & Integration Q&A

When should I choose the BioFlo 120 controller instead of a larger or parallel bioreactor system?

Choose it for single-unit benchtop work spanning 250 mL to 40 L via interchangeable glass (1–10 L) and BioBLU single-use vessels up to 50 L. It is not validatable, so select a validated platform for cGMP production or when parallel runs are required.

What supply and utility connections must be in place before the BioFlo 120 can be commissioned?

A single-phase 100–120/208–240 V ±10 %, 50/60 Hz, 10 A circuit via IEC-C14 with the correct regional plug, a gas supply sized to 20 SLPM maximum, and a 10 psig (0.69 barg) water quick-connect if the water-cooled condenser is used.

What maintenance items and accessories are not included in the base BioFlo 120 delivery?

Vessels are not part of the controller: glass 1–10 L autoclavable vessels or BioBLU single-use bags must be ordered separately, as must the water-cooled condenser or electric heater band option. The supplied facts list no service intervals or consumable schedule; obtain these from Eppendorf.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Fermentors Bioreactors Brochure BioFlo 120 Keep Growing
Brochure ·4,4 МБ ·8 pp.
View PDF