Eppendorf New Brunswick S41i - CO 2 Incubator Shaker
Eppendorf ·Made in Germany · In Active Production

Eppendorf New Brunswick S41i - CO 2 Incubator Shaker

Eppendorf New Brunswick S41i - CO 2 Incubator Shaker — Incubators with Capacity 170 L.

The New Brunswick S41i is a 170 L benchtop CO2 incubator shaker combining a triple-eccentric counterbalanced Innova drive (25–400 rpm, 2.5 cm orbit) with 4–50 °C and 0.2–20 % CO2 control in a seamless chamber. It is stackable or floor-mounted, intended for suspension-cell and microbial cultivation requiring simultaneous temperature, CO2 and agitation.

Capacity
170 L

Full specifications

Core Performance & Functional Specifications
Capacity 170 L
Audible And Visual Alarms yes
Available Program Modes Constant speed and temperature
Benchtop (b), Under Bench (u), Floor (f) Or Stackable (s) U, F, S
Bms Relay standard
Co 2 Control Increment 0.1 %
Co 2 Range 0.2...20 %
Co 2 Stability At 5 % Co 2 0.2 %
Co 2 Uniformity 0.1 %
Door Opening opening to front
Drive Mechanism triple-eccentric counterbalanced drive
High Temperature Disinfection (htd) 120 °C
Memory non volatile with automatic power failure restart
Motor Type Solid state, DC brushless motor
On-board Data Logging standard
Orbit 2.5 cm
Platform Size (cm/in) 36 cm
Remote Device Monitoring And Notifications (visionize ® ) VisioNize ® box enabled
Sealed Inner Glass Doors standard
Segmented Door Options –
Temperature Accuracy 0.2 °C
Temperature Control Increment 0.1 °C
Temperature range 4...50 °C
Temperature Stability At 37 °c 0.1 °C
Temperature uniformity 0.25 °C
No. of compartments mfr 1 (2. optional)
Timer mfr Continuous
Dimensions (W × D × H) mfr 87,5 × 73 × 85 cm / 34,4 × 28,7 × 33,5 in
Speed range mfr 25 – 400 rpm (stacked: 25 - 250/400 rpm for top/
Perforated shelves mfr standard
Shaking mfr standard
Seamless chamber mfr standard
In-line gas regulator mfr standard
Dimensions, Weight & Mechanical Design
Product Weight 154 kg
External depth (with lid/door open) mfr 144.8 cm (57 in)
Electrical, Power & Drive Specifications
Power supply mfr 230 V ± 10 %, 50/60 Hz
Interfaces, Connections & Control
Data Export Interface Ethernet
Power Plug power plug type F
Access port mfr 1
Standards, Safety & General Data
Cetlus And Ce Marked yes
Number Of Shelves (standard/max) 1

Description

Construction and positioning

Behavior under load and in different modes

Control, data and operation

Integration & Operating Notes

Mounting
Allow 144.8 cm clear depth for the open front door

The external depth with the door open is 144.8 cm, so bench or floor placement must leave that clearance in front of the unit for loading and for the sealed inner glass doors; the closed footprint is 87.5 × 73 cm and the unit weighs 154 kg, which also governs floor loading and lifting equipment.

Factory Specification Sheet
Mounting
Stacked operation caps the top unit at 250 rpm

When two units are stacked, the speed range is restricted to 25–250/400 rpm for top/bottom unit respectively; a protocol requiring more than 250 rpm on the upper unit cannot be run in a stacked configuration and must be assigned to the lower position or a non-stacked installation.

Factory Specification Sheet
Electrical
Supply must be 230 V ±10 %, 50/60 Hz with type F receptacle

The unit is specified only for 230 V ± 10 % at 50/60 Hz and is fitted with a type F (Schuko) power plug; a 115 V supply or a non-F receptacle requires a site change or an appropriate adapter arrangement, and the ±10 % tolerance must be respected at the point of connection.

Factory Specification Sheet
Control & I/O
Non-volatile memory restarts automatically after power failure

Because memory is non-volatile with automatic power-failure restart, the unit resumes its set speed, temperature and CO2 conditions after a mains interruption; engineers integrating the BMS relay or VisioNize box should treat a power-loss event as a restart, not a shutdown, and alarm logic must distinguish the two.

Factory Specification Sheet
Process Limits
CO2 control starts at 0.2 %, not at zero

The CO2 range is 0.2–20 % with 0.1 % increments; protocols needing a true 0 % CO2 atmosphere (for example certain anaerobic or non-CO2 incubations) fall outside the specified control range and require a different chamber or gas strategy.

Factory Specification Sheet
Maintenance
Plan a 120 °C HTD cycle between sensitive runs

High-temperature disinfection is available at 120 °C; scheduling an HTD cycle requires the chamber to be emptied of samples and heat-sensitive accessories, and the cooldown back into the 4–50 °C working range must be accounted for in the run schedule.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the S41i rather than a larger CO2 incubator shaker such as the CellXpert CS220?

Pick the S41i for a 170 L single-compartment benchtop workload at 25–400 rpm and 4–50 °C, especially where under-bench, floor or stacked placement is needed. The CS220 is the larger alternative referenced in the brochure when 170 L and the 36 cm platform are insufficient.

What supply and data connections must the host facility provide for this unit?

A 230 V ± 10 %, 50/60 Hz supply with a type F receptacle, plus an Ethernet drop for data export and VisioNize box monitoring. A standard BMS relay is wired for remote alarm signalling, and one access port is available for probe or gas-line routing.

Can I install the S41i under a bench or stack two units, and what limits apply?

Yes: it is rated for under-bench, floor or stacked use, but the open door needs 144.8 cm clear depth and the 154 kg weight must be supported. In a stacked pair the top unit is limited to 250 rpm while the bottom can reach 400 rpm.

What is not included in the base delivery that I may need to order?

The standard unit ships with one perforated shelf, one access port and an in-line gas regulator. A second compartment is optional, and additional shelves or probe feedthroughs are not part of the base configuration; confirm these against the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
CO2 Incubators Brochure New Brunswick S41i CO2 Incubator Shaker CO2 In
Brochure ·1,8 МБ ·8 pp.
View PDF