Eppendorf SpinPro ® 6 R - Smart High-Performance Centrifuge — Centrifuges.

The SpinPro 6 R is a refrigerated high-performance laboratory centrifuge with a 1600 W motor, reaching 13,500 rpm and 20,020 × g with fixed-angle rotors. Its −11 to 40 °C temperature range and 99-program memory distinguish it as the refrigerated, high-speed member of the SpinPro line. It is used for high-throughput pelleting, plate centrifugation, and temperature-sensitive separations.

Full specifications

Core Performance & Functional Specifications
Acceleration/braking Ramps 9
Act Label yes
Blood Collection Tubes 60 mm
Capacity 60 gram
Conical Tubes 34 mL
Fixed-angle Rotors For High-speed Applications yes
Max. Rcf 20020 g
Max. Rcf With Fixed-angle Rotor 20020 g
Max. Rcf With Swing-bucket Rotor 4300 g
Number Of Programs 99
Plate Rotor Options For Mtp, Pcr Or Dwp yes
Plates 10
Rotational speed 1...13500 rpm
Supporting Gmp/glp 21
Temperature range -11...40 °C
Universal Adapters For Conical Tubes, Plates And Bottles yes
Rotors available mfr 5
Timer mfr 1 s to 99 h 59 min 59 s, with continuous run fun
Dimensions (W × D × H) mfr 70,6 × 74,5 × 38,5 cm / 27,8 × 29,3 × 15,2 in
Rotor S-2xUniversal ID mfr ≤62 dB(A)
Rotor FA-6x250 ID mfr ≤62 dB(A)
Rotor FA-10x50 ID mfr ≤65 dB(A)
Rotor FA-48x2 ID mfr ≤70 dB(A)
Rotor FA-30x2 ID mfr ≤70 dB(A)
Dimensions, Weight & Mechanical Design
Height (with Open Lid) 86.7 cm
Product Weight 100 kg
Footprint (dimensions w/o front panel, WxD) mfr 70 × 70 cm, 27.6 × 27.6 in
Electrical, Power & Drive Specifications
Max. Power Consumption 1600 W
Power supply mfr 220 – 240 V, 50 – 60 Hz
Interfaces, Connections & Control
Power Plug power plug type EF
Operating Conditions, Environment & Protection
Cooling refrigerated
Noise level 70 dB

Description

Construction and positioning

Behavior under load and media

Control and operation

Integration & Operating Notes

Electrical
Supply must match 220–240 V, 50–60 Hz with type EF plug

The unit is rated only for 220–240 V at 50–60 Hz and draws 1600 W; connecting to a 110–120 V circuit or using an incompatible receptacle will prevent operation and may damage the drive. Confirm the site provides the type EF outlet and a circuit sized for the full motor power.

Factory Specification Sheet, Power supply and motor_power
Mounting
Allow 86.7 cm clearance for the open lid

The bench or floor location must accommodate the 70.6 × 74.5 cm footprint and provide at least 86.7 cm of vertical clearance when the lid is open, plus access for loading and unloading rotors. The 100 kg weight requires a level, load-bearing surface.

Factory Specification Sheet, Dimensions and height with open lid
Process Limits
Do not exceed 4,300 × g with swing-bucket rotors

Maximum RCF is 20,020 × g only with fixed-angle rotors; swing-bucket operation is limited to 4,300 × g. Exceeding the rotor-specific limit risks rotor failure and invalidates separation results, so the run setpoint must be checked against the installed rotor type.

Factory Specification Sheet, max-rcf-with-swing-bucket-rotor and max-rcf-with-fixed-angle-rotor
Cooling & Media
Refrigeration covers −11 to 40 °C only

Temperature control is limited to −11…40 °C; runs requiring lower temperatures or operation outside this band are not supported. Samples and adapters should be equilibrated within this range before starting a temperature-sensitive protocol.

Factory Specification Sheet, temperature-range

Selection & Integration Q&A

When should I choose the SpinPro 6 R rather than a non-refrigerated or lower-speed centrifuge in the line?

Choose the 6 R when you need both sub-ambient cooling (−11 to 40 °C) and high-speed fixed-angle runs up to 20,020 × g at 13,500 rpm. If runs are ambient-only or limited to swing-bucket work at 4,300 × g, a non-refrigerated or swing-bucket-only unit is sufficient.

What rotor and adapter set must be ordered to spin 34 mL conical tubes and microplates on this centrifuge?

Use the S-2×Universal ID swing-bucket rotor with universal adapters 1–3 for conical tubes, plates, and bottles; plate rotors accept MTP, PCR, and DWP formats (10 plates). Fixed-angle rotors FA-6×250 ID, FA-10×50 ID, FA-48×2 ID, and FA-30×2 ID cover high-speed tube work.

What site conditions and duty limits apply when installing the SpinPro 6 R?

Provide a 220–240 V, 50–60 Hz supply with type EF plug and 1600 W capacity, a level surface for the 100 kg unit, and 86.7 cm vertical clearance for the open lid. Keep ambient and sample temperatures within the −11 to 40 °C control range.

What maintenance and accessories are not included with the base centrifuge delivery?

The brochure lists rotors S-2×Universal ID, FA-48×2 ID, FA-30×2 ID, FA-6×250 ID, FA-10×50 ID and universal adapters 1–3 as separate items; ordering information for the centrifuge itself is not printed and must be obtained from the local sales representative. No service interval is stated in the supplied documents.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Centrifugation Brochure SpinPro 6 R centrifuge Effortless Every Time.p
Brochure ·4,8 МБ ·13 pp.
View PDF