Peter Huber Kältemaschinenbau DC30
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau DC30

Peter Huber Kältemaschinenbau DC30 — Immersion coolers.

The DC30 is a flow-through cooler with no integral pump, rated for -30 to 50 °C and 0.2 kW cooling at 15 °C evaporating temperature. Its M16x1 male fluid connection and 220–240 V 1~/2~ supply distinguish it from pumped siblings DC31/DC32. It serves as a compact chiller stage in external circulation systems.

Peter Huber Kältemaschinenbau Durchflusskuehler Series — Model Comparison & Selection

Model Weight, kgAmbient temperature limit, °CPower supplyProtection ratingPump connectionSafety class
DC30 Current 165–40220-240V 1~/2~ 50/60HzIP20M16x1 AG maleI / NFL
DC31 235–40220-240V 1~/2~ 50/60HzIP20M16x1 AG maleI / NFL
DC32 ——————

Full specifications

Core Performance & Functional Specifications
Dimensions (w × D × H) 190 x 250 x 360 mm
Pump connection M16x1 AG male
Pump speed adjustable no
Pump type no pump
Temperature range -30...50 °C
Dimensions, Weight & Mechanical Design
Weight 16 kg
Electrical, Power & Drive Specifications
Fuse rating 2 A
Power supply 220-240V 1~/2~ 50/60Hz
Current consumption max. mfr 1, 4 A
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Cooling capacity mfr 15:0, 2; 0:0, 15; -20:0, 07 °C / kW (at ambient 20°C)
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Thermal behavior and capacity

Electrical and control

Installation and environment

Integration & Operating Notes

Process Limits
Stay within -30 to 50 °C fluid temperature

The cooler is rated only for an operating temperature range of -30 to 50 °C. Operating outside this window risks damage or invalid performance; select the unit only for applications whose fluid temperature stays inside this envelope.

Datasheet DC30 Durchflusskühler, Overview
Process Limits
Size capacity at the actual evaporating temperature

Cooling capacity is 0.2 kW at 15 °C, 0.15 kW at 0 °C and 0.07 kW at -20 °C. Because capacity drops sharply as the operating point falls, the 15 °C figure must not be used for sizing a low-temperature duty; use the capacity at the real evaporating temperature.

Datasheet DC30 Durchflusskühler, Performance
Cooling & Media
R-290 charge requires flammable-refrigerant assessment

The refrigerant is R-290 (propane, A3, H220) with a 0.05 kg charge. The installation area must be assessed for flammable refrigerant handling and ignition sources before commissioning.

Datasheet DC30 Durchflusskühler, Safety
Mounting
Ambient must stay between 5 and 40 °C

Room temperature must be verified before commissioning. Capacity figures are valid at 20 °C ambient; if the ambient temperature rises, cooling capacity may drop, so warmer rooms require derating.

Datasheet DC30 Durchflusskühler, Operation
Mounting
IP20 enclosure needs a dry, protected location

The device is IP20 and must not be exposed to water or dust ingress. Plan the installation in a dry, protected area and respect the space requirements around the unit for condenser airflow and service access.

Datasheet DC30 Durchflusskühler, Installation
Electrical
Voltage and frequency tolerances must coincide

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%. Combinations such as -5% voltage with +2% frequency are not allowed; verify the site supply quality against this combined limit before connection.

Datasheet DC30 Durchflusskühler, Installation
Electrical
Order the country-specific plug with the unit

Single/two-phase devices are delivered with a power cable and country-specific plug that must be specified at ordering. Confirm the destination plug type so the correct cable set is supplied.

Datasheet DC30 Durchflusskühler, Installation
Electrical
Class A EMC limits restrict use to industrial areas

The equipment is EMC Class A, Group 1 to EN55011 and may cause radio interference in residential areas. It is intended for industrial environments; assess EMC compatibility with nearby sensitive equipment.

Datasheet DC30 Durchflusskühler, Compliance

Selection & Integration Q&A

When should I choose the DC30 rather than a sibling such as DC31 or DC32?

Choose the DC30 when the circulation is driven by an external pump or system pressure: it has no integral pump and a single M16x1 male fluid connection. Siblings DC31/DC32 are separate models; their configurations are not covered by the DC30 datasheet, so verify their pump and connection data before substituting.

What must the external circuit and power supply provide to integrate the DC30?

The fluid side needs an external pump or system pressure and hoses/fittings matching the M16x1 AG male thread. The electrical side needs 220–240 V 1~/2~ 50/60 Hz, max 1.4 A, protected at 2 A, with voltage tolerance ±5% only together with frequency tolerance ±2%.

What mounting and ambient limits apply to the DC30 installation?

Install in a dry, protected location: IP20 forbids water or dust ingress. Ambient must stay between 5 and 40 °C, and capacity is rated at 20 °C room temperature, so warmer rooms require derating. Respect the space requirements around the unit for airflow and service access.

What is supplied with the DC30 and what must be ordered or provided separately?

Single/two-phase units come with a power cable and country-specific plug, which must be specified at ordering. The pump is not included (no pump), and mating hoses/fittings for the M16x1 male connection are not part of the base delivery. No maintenance schedule is given in the available datasheet digest.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
DC30 Durchflusskühler
Datasheet ·59,3 КБ ·1 pp.
View PDF