Nabertherm H 125/LB, LT
Nabertherm H 125/LB, LT — Prozesse Unter Luft.
The H 125/LB, LT is a bottom-loading (top-hat) furnace with a 125-litre chamber (800 × 400 × 400 mm) and wire heating for a maximum temperature of 1280 °C. It is a 3-phase unit with 12 kW heating power and a 1250 kg total weight. Its 800 mm width and 400 mm height suit long, flat loads that are lowered into the chamber from below.
Full specifications
| Chamber volume | 125 l |
| Chamber volume | 125 l |
| Chamber volume | 125 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heatingpower in mfr | 12 |
| Inner dimensions (W × D × H) mfr | 800 × 400 × 400 mm |
| Outer dimensions (W × D × H) mfr | 1550 × 1500 × 2200 mm |
| Weight | 1250 kg |
| Weight | 1250 kg |
| Weight | 1250 kg |
| Max temperature | 1280 °C |
| Max temperature | 1280 °C |
| Max temperature | 1280 °C |
Description
Construction and positioning
- The H 125/LB, LT is a bottom-loading furnace: the heated chamber is formed by a top-hat (bell) that is lifted or lowered over a fixed base, so the load is placed on the hearth from below rather than pushed in through a front door.
- Chamber dimensions are 800 mm wide × 400 mm deep × 400 mm high, giving a 125-litre working volume that is wide and shallow — suited to long, flat parts or trays.
- The outer envelope is 1550 × 1500 × 2200 mm (W × D × H), and the unit weighs 1250 kg; the height reflects the lifting mechanism and the bell in its raised position.
- Heating is by wire elements, with a maximum chamber temperature of 1280 °C and 12 kW of installed heating power supplied from a 3-phase connection.
- No sibling models are listed in the verified data, so the H 125/LB, LT cannot be positioned against other sizes of the same series from these facts.
Behaviour under load
- No digitized curve points are available for this model, so heat-up rate, cooling behaviour and temperature uniformity cannot be stated from the verified data.
- The 12 kW heating power and 125-litre volume define the installed power density; actual achievable ramp rates depend on load mass and fixturing, which are not documented here.
- The 1280 °C maximum applies to the wire-heated chamber; no separate limit for the base or hearth is given in the verified facts.
Installation, control and operation
- The unit requires a 3-phase electrical supply; no voltage or current figures are stated in the verified specs, so the site supply must be confirmed against the nameplate before installation.
- The attached document digests (controller series 500 / MyNabertherm app, fiber-optics catalog, foundry and dental brochures) contain no model-specific installation, connection or control facts for the H 125/LB, LT; they are general Nabertherm literature and should not be used to infer this furnace's wiring or controller configuration.
- No certificates or application notes are listed for this model.
Integration & Operating Notes
The verified data states only that the furnace is a 3-phase unit with 12 kW heating power; no voltage, current or fuse rating is given. The site supply, cable cross-section and upstream protection must be sized from the nameplate and wiring diagram supplied with the unit, not from this card.
The furnace weighs 1250 kg and stands 2200 mm high with a 1550 × 1500 mm footprint. The floor and any substructure must support the furnace plus the workload, and the installation height must clear the bell in its raised position for loading from below.
The wire-heated chamber is rated to a maximum of 1280 °C. No separate limit for the hearth or base is stated in the verified facts, so process recipes should be checked against the chamber limit and any additional limits in the operating manual before first use.
Selection & Integration Q&A
Choose it when the load is long and flat and must be placed from below: the 800 × 400 × 400 mm chamber is wide and shallow, and bottom loading avoids pushing heavy parts through a front door. No sibling models are listed in the verified data, so comparison with other sizes must come from the full catalog.
The verified data gives only 3-phase and 12 kW; voltage, current and fuse ratings are not stated. Size the cable and upstream protection from the nameplate and wiring diagram delivered with the furnace, and have the supply checked by an electrician before commissioning.
No maintenance intervals, spare parts, cables or consumables are listed for the H 125/LB, LT in the verified facts, and the attached document digests contain no model-specific service information. Service schedule and scope of delivery must be taken from the operating manual and order confirmation.