Nabertherm HF 450/10 LB DB200-2
Nabertherm HF 450/10 LB DB200-2 — Bottom Loading Furnace Ltcc Applications.
The HF 450/10 LB DB200-2 is a bottom-loading chamber furnace with a 450 l workspace (750 × 750 × 800 mm) rated to 1000 °C and 54 kW heating power. Its 1850 × 1700 × 2700 mm outer envelope and bottom-load architecture suit LTCC firing where the charge is lifted into the chamber from below. Temperature uniformity is specified at 400 °C.
Full specifications
| Chamber volume | 450 l |
| Temperature uniformity | 400 °C |
| Heating power2in mfr | 54 |
| Inner dimensions (W × D × H) mfr | 750 × 750 × 800 mm |
| Outer dimensions (W × D × H) mfr | 1850 × 1700 × 2700 mm |
| Max temperature | 1000 °C |
Description
Construction and positioning
- Bottom-loading (LB) chamber furnace with a 450 l workspace measuring 750 mm wide × 750 mm deep × 800 mm high; the charge is raised into the chamber from below rather than front-loaded.
- Maximum working temperature 1000 °C with 54 kW installed heating power; outer dimensions 1850 × 1700 × 2700 mm define the floor footprint and headroom required.
- The DB200-2 suffix denotes the bottom-load drive/lift configuration; no sibling models are listed in the verified data, so no intra-series comparison can be stated.
Thermal behavior
- Temperature uniformity is specified at 400 °C; no uniformity figure is given for other setpoints, so do not extrapolate the 400 °C value to the 1000 °C maximum.
- No digitized heating or cooling curves are available for this model; thermal ramp behavior must be taken from the furnace controller documentation rather than assumed.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process data storage and AMS2750F instrumentation types; it does not print model-specific wiring or setpoints for the HF 450/10 LB.
- The remaining attached digests (fiber-optics glass, foundry, dental) cover other product lines and contain no actionable facts for this furnace.
Integration & Operating Notes
The 1000 °C figure is the maximum working temperature of this model; operating above it risks heating-element and insulation damage. The only published uniformity value is at 400 °C, so uniformity at higher setpoints is not guaranteed by the verified data.
The outer dimensions include the bottom-load lift travel; the installation must provide clear floor area for the 1850 × 1700 mm footprint and 2700 mm height, plus access for loading the bottom hearth from below and for service around the lift mechanism.
At 54 kW installed heating power the furnace draws a substantial three-phase current; the supply, fusing and cable cross-section must be sized by a qualified electrician against the nameplate data, which is not reproduced in the verified facts.
Process control, data storage and AMS2750F instrumentation types are described in the 500-series controller digest, not in a model-specific manual; confirm the ordered controller variant and its documentation before commissioning.
Selection & Integration Q&A
Choose it when the charge fits the 750 × 750 × 800 mm workspace and processes stay at or below 1000 °C with 54 kW heating power. No sibling models are listed in the verified data, so comparison against other sizes cannot be made from these facts.
A dedicated three-phase supply sized for 54 kW heating power, plus a Nabertherm 500-series controller (or equivalent) whose functions, data storage and AMS2750F instrumentation options are described in the separate controller document, not the furnace sheet.
The 1850 × 1700 × 2700 mm outer envelope includes the bottom-load lift; floor area and headroom must accommodate the lift travel and loading access from below. Duty-cycle limits are not stated in the verified facts and must be confirmed with the manufacturer.
The verified facts list no maintenance schedule, spare parts or accessories for this model; controller options and recorder/instrumentation variants are separate items per the controller digest. Service intervals must be obtained from the manufacturer's manual.