Nabertherm HT 160/18
Nabertherm HT 160/18 — Furnace Solutions 1800 Degc.
The HT 160/18 is a 160-litre high-temperature chamber furnace with molybdenum disilicide heating elements and fiber insulation, rated to 1800 °C on a 3-phase supply. Within the HT series it is the 160-litre, 1800 °C modification, distinguished from the 1700 °C siblings by its higher element and insulation class. It serves high-temperature sintering, melting and heat-treatment steps where a 500 × 550 × 550 mm working chamber is required.
Full specifications
| Chamber volume | 160 l |
| Electrical connection | 3-phase |
| Connected mfr | 21.5 |
| Inner dimensions (W × D × H) mfr | 500 × 550 × 550 mm |
| Outer dimensions (W × D × H) mfr | 1250 × 1040 × 2260 mm |
| Weight | 760 kg |
| Max temperature | 1800 °C |
Description
Construction and series positioning
- Chamber volume 160 l; inner dimensions 500 × 550 × 550 mm (W × D × H); outer dimensions 1250 × 1040 × 2260 mm; weight 760 kg.
- Molybdenum disilicide (MoSi2) heating elements with fiber insulation, maximum temperature 1800 °C.
- Within the HT series, the HT 160/18 is the 160-litre, 1800 °C variant; the HT 160/17 shares the chamber size but is rated to 1700 °C, while HT 29/17 and HT 64/17 are smaller 1700 °C chambers and HT 450/16 is a larger 1600 °C unit. Choose the /18 when the process requires the 1800 °C ceiling; choose a /17 or /16 sibling when the lower temperature is sufficient.
Behavior under load and media
- The MoSi2 elements and fiber insulation are selected for the 1800 °C class; no cooling or atmosphere data is given in the verified facts, so no load curves or media behavior can be stated.
- No digitized curve points are available for this model; temperature uniformity and heat-up behavior must be taken from the controller documentation and site commissioning.
Installation, connection and control
- Electrical connection is 3-phase; the connected load is listed as 21.5 (unit not printed in the source), so the supply and protection must be sized against the nameplate rather than this card.
- The controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; recorder and controller options are separate selections.
- The attached document digests do not contain model-specific installation sections for the HT 160/18; mounting, clearances and commissioning steps must be taken from the furnace instruction manual supplied with the unit.
Integration & Operating Notes
The verified facts list the connected load as 21.5 without a printed unit, so the apparent power, current per phase and required protection cannot be derived here. The electrical installer must read the furnace nameplate and the instruction manual before sizing cables, fuses and the isolator, and must confirm phase rotation and earthing.
The MoSi2 elements and fiber insulation are rated to a maximum temperature of 1800 °C. Controller setpoints, over-temperature limits and any boost or dry-out programs must be configured so that the chamber cannot be driven above this value, because exceeding it degrades the elements and insulation.
The controller documentation covers the 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but the furnace card does not state which controller is fitted. Specify the controller, over-temperature protection and any recorder explicitly at order, and verify the thermocouple type against the 1800 °C range.
Selection & Integration Q&A
Pick the HT 160/18 when the process needs the 1800 °C ceiling in a 160-litre, 500 × 550 × 550 mm chamber. The HT 160/17 gives the same chamber at 1700 °C; the HT 64/17 and HT 29/17 are smaller 1700 °C chambers, and the HT 450/16 is larger but limited to 1600 °C.
The card lists a 3-phase connection and a connected load of 21.5 without a printed unit, so the installer must read the nameplate for voltage, current per phase and power, then size cables, fuses and the isolator accordingly. Phase rotation, earthing and the over-temperature limit setting must also be confirmed.
The controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types. The furnace card does not state a fitted controller, so the controller, over-temperature protection and any recorder must be specified at order and matched to the 1800 °C thermocouple range.