Nabertherm HT 160/18
Nabertherm ·Made in Germany · In Active Production

Nabertherm HT 160/18

Nabertherm HT 160/18 — Furnace Solutions 1800 Degc.

The HT 160/18 is a 160-litre high-temperature chamber furnace with molybdenum disilicide heating elements and fiber insulation, rated to 1800 °C on a 3-phase supply. Within the HT series it is the 160-litre, 1800 °C modification, distinguished from the 1700 °C siblings by its higher element and insulation class. It serves high-temperature sintering, melting and heat-treatment steps where a 500 × 550 × 550 mm working chamber is required.

Full specifications

Core Performance & Functional Specifications
Chamber volume 160 l
Electrical connection 3-phase
Connected mfr 21.5
Inner dimensions (W × D × H) mfr 500 × 550 × 550 mm
Outer dimensions (W × D × H) mfr 1250 × 1040 × 2260 mm
Dimensions, Weight & Mechanical Design
Weight 760 kg
Operating Conditions, Environment & Protection
Max temperature 1800 °C

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Size the 3-phase supply against the nameplate, not the card

The verified facts list the connected load as 21.5 without a printed unit, so the apparent power, current per phase and required protection cannot be derived here. The electrical installer must read the furnace nameplate and the instruction manual before sizing cables, fuses and the isolator, and must confirm phase rotation and earthing.

Factory Specification Sheet; Instruction Manual (electrical connection section
Process Limits
Do not exceed the 1800 °C element-class ceiling

The MoSi2 elements and fiber insulation are rated to a maximum temperature of 1800 °C. Controller setpoints, over-temperature limits and any boost or dry-out programs must be configured so that the chamber cannot be driven above this value, because exceeding it degrades the elements and insulation.

Factory Specification Sheet
Control & I/O
Controller and recorder are separate selections

The controller documentation covers the 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but the furnace card does not state which controller is fitted. Specify the controller, over-temperature protection and any recorder explicitly at order, and verify the thermocouple type against the 1800 °C range.

Prozesssteuerung englisch (controller series 500 and MyNabertherm app

Selection & Integration Q&A

When should I choose the HT 160/18 rather than the HT 160/17 or the smaller HT 64/17?

Pick the HT 160/18 when the process needs the 1800 °C ceiling in a 160-litre, 500 × 550 × 550 mm chamber. The HT 160/17 gives the same chamber at 1700 °C; the HT 64/17 and HT 29/17 are smaller 1700 °C chambers, and the HT 450/16 is larger but limited to 1600 °C.

What must be verified before connecting the furnace to the site 3-phase supply?

The card lists a 3-phase connection and a connected load of 21.5 without a printed unit, so the installer must read the nameplate for voltage, current per phase and power, then size cables, fuses and the isolator accordingly. Phase rotation, earthing and the over-temperature limit setting must also be confirmed.

Which controller and instrumentation options apply to this furnace?

The controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types. The furnace card does not state a fitted controller, so the controller, over-temperature protection and any recorder must be specified at order and matched to the 1800 °C thermocouple range.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF