Nabertherm K 240/12
Nabertherm K 240/12 — Tilting Furnaces Electrically Heated Or Gas Fired.
The K 240/12 is an electrically heated tilting furnace from Nabertherm's K series, built for melting and holding metals at up to 1200 °C. It uses crucible TP 587 and sits between the K 150/12 and K 360/12 in capacity. Its tilting design supports controlled pouring in foundry and process-metal systems.
Full specifications
| Heating power | 80 watt |
| Crucible mfr | TP 587 |
| Capacityin kg mfr | 570 |
| Capacityin kg mfr | 1500 |
| Melting performance3,6in kg mfr | 1801 |
| Consumptionmelting6kWh mfr | 0.41 |
| Consumption holding Lid closed mfr | 8/171 |
| Outer dimensions (W × D × H) mfr | 2260 × 1760 × 1860 mm |
| Weight | 2800 kg |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- The K 240/12 is a tilting furnace with a crucible type TP 587 and an outer envelope of 2260 × 1760 × 1860 mm; the unit weighs 2800 kg.
- Within the K series it is the mid-size 240 frame, flanked by the smaller K 150/12 and the larger K 360/12; the K 40/13 belongs to the higher-temperature 1300 °C line and is not a like-for-like alternative.
- The furnace is electrically heated with a maximum temperature of 1200 °C.
Thermal and melting behavior
- Melting performance is stated as 180¹ kg (footnote not reproduced in the verified facts) and melting consumption as 0.4¹ kWh; holding consumption with the lid closed is given as 8/17¹. These values are tied to the printed conditions and should be read from the original table before sizing a melt cycle.
- The heating power entry of 80 W in the matched specs is not consistent with a 1200 °C melting furnace of this size and is therefore not used here; the electrical rating must be taken from the furnace nameplate or the original data sheet.
- No digitized curve points were supplied, so no cooldown or load-response curve is asserted.
Control and operation
- The attached controller digest covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print model-specific wiring for the K 240/12.
- The foundry overview lists the K series from K 80/12 to K 400/12, confirming this model belongs to the standard electrically heated tilting range rather than the KB, KBR or KC lines.
- Installation, connection and tilting-operation details are not contained in the supplied digests and must be taken from the K-series instruction manual.
Integration & Operating Notes
The furnace is rated to a maximum of 1200 °C. Running above this limit risks crucible and heating-element damage; the 1300 °C duty belongs to the separate K 40/13 line, not to this model.
The K 240/12 is specified with crucible TP 587. Charge and melt weights must be checked against the original capacity table, because the verified extra specs list two different capacity figures (570 kg and 1500 kg) without labels tying them to a configuration.
The matched spec table gives 80 W heating power, which is not credible for a 1200 °C furnace of this mass. Size the supply, protection and cable cross-section from the furnace nameplate and the K-series manual before installation.
The controller digest describes the 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no model-specific terminal plan. Confirm the ordered controller variant and its interfaces against the furnace order documentation.
The furnace weighs 2800 kg and occupies 2260 × 1760 × 1860 mm. The floor and tilting clearance must be rated for the moving load and for the pour arc; the supplied digests give no anchor or foundation data, so obtain the installation drawing.
Holding consumption is quoted at 8/17¹ kWh with the lid closed, so lid fit and crucible condition directly affect energy use. Inspect the crucible and lid seal on the interval given in the K-series manual; no interval is printed in the supplied digests.
Selection & Integration Q&A
Pick the K 240/12 when the melt size falls between the K 150/12 and K 360/12 frames and 1200 °C is sufficient. Move to the K 360/12 for larger batches, or to the K 40/13 line only if 1300 °C duty is required; the K 40/13 is a different temperature class, not a capacity step.
Use the furnace nameplate for voltage, current and power, because the digest's 80 W heating-power entry is not usable for sizing. Confirm the ordered controller variant from the 500 series or MyNabertherm options and its signal interfaces against the order documentation before wiring.
Allow for a 2800 kg machine measuring 2260 × 1760 × 1860 mm, with clearance for the tilting pour arc and a floor rated for the moving load. Keep the process below the 1200 °C maximum. The supplied digests contain no anchor or foundation data, so request the installation drawing.
Plan for crucible TP 587 replacement and lid-seal upkeep, since holding consumption is quoted with the lid closed. Controller hardware, recorder options and cabling are separate items described in the controller digest, not part of the base furnace; service intervals must be taken from the K-series manual.