Nabertherm K 240/12
Nabertherm ·Made in Germany · In Active Production

Nabertherm K 240/12

Nabertherm K 240/12 — Tilting Furnaces Electrically Heated Or Gas Fired.

The K 240/12 is an electrically heated tilting furnace from Nabertherm's K series, built for melting and holding metals at up to 1200 °C. It uses crucible TP 587 and sits between the K 150/12 and K 360/12 in capacity. Its tilting design supports controlled pouring in foundry and process-metal systems.

Full specifications

Core Performance & Functional Specifications
Heating power 80 watt
Crucible mfr TP 587
Capacityin kg mfr 570
Capacityin kg mfr 1500
Melting performance3,6in kg mfr 1801
Consumptionmelting6kWh mfr 0.41
Consumption holding Lid closed mfr 8/171
Outer dimensions (W × D × H) mfr 2260 × 1760 × 1860 mm
Dimensions, Weight & Mechanical Design
Weight 2800 kg
Operating Conditions, Environment & Protection
Max temperature 1200 °C

Description

Construction and series positioning

Thermal and melting behavior

Control and operation

Integration & Operating Notes

Process Limits
Do not exceed 1200 °C crucible temperature

The furnace is rated to a maximum of 1200 °C. Running above this limit risks crucible and heating-element damage; the 1300 °C duty belongs to the separate K 40/13 line, not to this model.

Factory Specification Sheet
Process Limits
Match crucible TP 587 and charge weight to the 240 frame

The K 240/12 is specified with crucible TP 587. Charge and melt weights must be checked against the original capacity table, because the verified extra specs list two different capacity figures (570 kg and 1500 kg) without labels tying them to a configuration.

Factory Specification Sheet
Electrical
Take the electrical rating from the nameplate, not the digest

The matched spec table gives 80 W heating power, which is not credible for a 1200 °C furnace of this mass. Size the supply, protection and cable cross-section from the furnace nameplate and the K-series manual before installation.

Factory Specification Sheet; K-series Instruction Manual
Control & I/O
Controller functions are documented separately from the furnace

The controller digest describes the 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no model-specific terminal plan. Confirm the ordered controller variant and its interfaces against the furnace order documentation.

Prozesssteuerung englisch
Mounting
Plan for a 2800 kg tilting machine with 2260 mm width

The furnace weighs 2800 kg and occupies 2260 × 1760 × 1860 mm. The floor and tilting clearance must be rated for the moving load and for the pour arc; the supplied digests give no anchor or foundation data, so obtain the installation drawing.

Factory Specification Sheet
Maintenance
Crucible and lid condition govern holding consumption

Holding consumption is quoted at 8/17¹ kWh with the lid closed, so lid fit and crucible condition directly affect energy use. Inspect the crucible and lid seal on the interval given in the K-series manual; no interval is printed in the supplied digests.

Factory Specification Sheet; K-series Instruction Manual

Selection & Integration Q&A

When should I choose the K 240/12 rather than the K 150/12 or K 360/12?

Pick the K 240/12 when the melt size falls between the K 150/12 and K 360/12 frames and 1200 °C is sufficient. Move to the K 360/12 for larger batches, or to the K 40/13 line only if 1300 °C duty is required; the K 40/13 is a different temperature class, not a capacity step.

What must be verified before connecting the K 240/12 to the plant electrical supply and controller?

Use the furnace nameplate for voltage, current and power, because the digest's 80 W heating-power entry is not usable for sizing. Confirm the ordered controller variant from the 500 series or MyNabertherm options and its signal interfaces against the order documentation before wiring.

What installation and duty limits apply to the K 240/12 on the foundry floor?

Allow for a 2800 kg machine measuring 2260 × 1760 × 1860 mm, with clearance for the tilting pour arc and a floor rated for the moving load. Keep the process below the 1200 °C maximum. The supplied digests contain no anchor or foundation data, so request the installation drawing.

What maintenance and consumables should be planned beyond the base furnace delivery?

Plan for crucible TP 587 replacement and lid-seal upkeep, since holding consumption is quoted with the lid closed. Controller hardware, recorder options and cabling are separate items described in the controller digest, not part of the base furnace; service intervals must be taken from the K-series manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF