Nabertherm KBR 240/11
Nabertherm ·Made in Germany · In Active Production

Nabertherm KBR 240/11

Nabertherm KBR 240/11 — Tilting Furnaces Electrically Heated Or Gas Fired.

The KBR 240/11 is a gas-fired tilting furnace with a recuperative burner, rated to 1100 °C and fitted with a TP 587 crucible holding 570 kg of aluminum melt. Within the KBR series (240/11 to 400/11), it is the smallest capacity variant, suited to melting and holding duty in foundry charging systems.

Full specifications

Core Performance & Functional Specifications
Crucible mfr TP 587
Capacityin kg mfr 570
Burneroutput mfr 390
Melting performance2in kg mfr 3201
Consumptionmelting in kWh mfr 1.1 - 1.41
ConsumptionholdingLid closed mfr 13
Outer dimensions (W × D × H) mfr 2300 × 1980 mm
Dimensions, Weight & Mechanical Design
Weight 3600 kg
Operating Conditions, Environment & Protection
Max temperature 1100 °C

Description

Construction and series positioning

Thermal performance

Control and documentation

Integration & Operating Notes

Process Limits
Do not exceed 1100 °C furnace temperature

The 1100 °C maximum is the ceiling for the furnace chamber and crucible; operating above it risks crucible and lining damage and invalidates melt quality assumptions. The controller setpoint and over-temperature protection must be configured so the limit cannot be exceeded during holding or superheat.

Factory Specification Sheet
Mounting
Floor and foundation must carry 3600 kg plus melt and ladle loads

The unit weight of 3600 kg is the empty furnace; add the 570 kg melt capacity and tilting loads when specifying the foundation. The tilting axis and pouring side require free space beyond the 2300 × 1980 mm footprint for the ladle and operator access.

Factory Specification Sheet
Control & I/O
Controller platform is documented separately from the furnace

The controller digest describes the 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no KBR-specific wiring. The project engineer must obtain the model-specific terminal plan and thermocouple schedule from the factory before panel design.

Prozesssteuerung englisch (controller digest
Maintenance
Crucible and recuperative burner are the wear-critical items

The TP 587 crucible and the recuperative burner are the components most exposed to thermal cycling and melt contact. Inspection intervals for crucible wall condition and burner/flue passages should be set from the operating manual; no interval is printed in the supplied digests, so the factory maintenance schedule must be requested.

Foundry english (catalog digest

Selection & Integration Q&A

When should I choose the KBR 240/11 rather than a larger KBR recuperative model?

Pick the 240/11 when the melt demand fits its 570 kg TP 587 crucible and 1100 °C ceiling. Higher-numbered KBR models (up to 400/11) exist for larger melt volumes; the 240/11 is the smallest in the recuperative range, so growth margin must be planned explicitly.

What must be verified for the gas burner train and flue connection before installation?

The factory table lists burner output 390 and melting consumption 1.1 – 1.41 kWh without a clear unit basis. The gas supply pressure, burner train and flue must be sized against the factory-clarified figures, and the recuperative air path must be ducted per the installation drawing.

Which consumables and accessories are not part of the base delivery?

The supplied digests do not list a scope of delivery. The TP 587 crucible is identified as the fitted crucible, but spare crucibles, thermocouples, controller options and the MyNabertherm app package must be ordered separately and confirmed against the factory order confirmation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF