Nabertherm KTR 22500 — Heating Cabinets Chamber Ovens.

The KTR 22500 is a 22,500-litre electrically heated chamber oven with a 2000 × 4500 × 2500 mm interior, rated to 260 °C and powered by a 108 kW three-phase heating system. It is the largest chamber volume in the KTR series, positioned well above the KTR 1500 through KTR 6125 for full-load batch or bulk thermal processing.

Nabertherm KTR Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionMax temperature, °C
KTR 22500 Current 225003-phase260
KTR 4500 45003-phase260

Full specifications

Core Performance & Functional Specifications
Chamber volume 22500 l
Electrical connection 3-phase
Heating power in kW1 mfr 108
Inner dimensions (W × D × H) mfr 2000 × 4500 × 2500 mm
Outer dimensions (W × D × H) mfr 3015 × 5300 × 3550 mm
Operating Conditions, Environment & Protection
Max temperature 260 °C

Description

Construction and series positioning

Behaviour and media

Control and operation

Integration & Operating Notes

Electrical
108 kW heating load demands a dedicated three-phase supply study

The 108 kW installed heating power on a three-phase connection sets the service size, cable cross-section and upstream protection; the supply and switchgear must be engineered for this load before the oven is sited, and no single voltage is stated in the verified facts, so the site voltage must be confirmed against the order.

Factory Specification Sheet
Process Limits
260 °C is the ceiling; do not treat the KTR as a 300 °C oven

The KTR series tops out at 260 °C, below the TR ovens rated to 300 °C; processes requiring higher temperature or forced convection up to 900 °C belong to the NAT/NA furnace family, not to this chamber oven.

Fiber optics glass catalog section
Process Limits
Solvent-bearing loads require the EN 1539 LS safety package

LS variants with safety technology per EN 1539 are catalogued for TR and KTR models, but the verified facts for the KTR 22500 do not confirm an LS configuration; any process releasing flammable vapours must be checked against the ordered safety equipment before operation.

Fiber optics glass catalog section
Control & I/O
Controller and recorder are separate selections from the oven

The series 500 controller and MyNabertherm app documentation covers process-data storage and AMS2750F instrumentation types but prints no furnace model codes; controller, recorder and uniformity instrumentation must be specified alongside the KTR 22500 rather than assumed from the controller manual.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the KTR 22500 rather than a smaller KTR sibling such as the KTR 6125 or KTR 4500?

Pick the KTR 22500 when the batch needs the full 22,500 l chamber (2000 × 4500 × 2500 mm) at up to 260 °C; the KTR 1500, 3100, 4500 and 6125 cover smaller interiors, so a smaller sibling is the right choice when the load fits and the 108 kW heating load and 3015 × 5300 × 3550 mm envelope are not justified.

What supply and control infrastructure must be in place before the KTR 22500 can be commissioned?

A three-phase supply engineered for the 108 kW heating power, plus a controller from the Nabertherm series 500 platform (with MyNabertherm app and optional recorder/AMS2750F instrumentation). The verified facts state three-phase connection but no voltage, so the site voltage must be confirmed against the order before switchgear is sized.

What installation and process limits apply to siting and loading the KTR 22500?

The oven occupies a 3015 × 5300 × 3550 mm outer envelope around its 2000 × 4500 × 2500 mm chamber, so transport route, floor loading and door swing must be planned from the outer dimensions. Chamber temperature is limited to 260 °C, and solvent-releasing loads need the EN 1539 LS safety package, which is not confirmed for this unit in the verified facts.

What is not included in the base delivery and must be ordered or planned separately?

The controller (series 500 with MyNabertherm app), recorder and AMS2750F temperature-uniformity instrumentation are documented as separate controller/recorder options, not integral to the oven. The verified facts list no accessories, cables or consumables, so the supply-side switchgear and any LS safety equipment must be confirmed at order stage.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF