Nabertherm KTR 3100
Nabertherm KTR 3100 — Heating Cabinets Chamber Ovens.
The KTR 3100 is a 3100-litre electrically heated chamber oven with a 260 °C maximum temperature, built for bulk thermal processing in a 1250 × 1250 × 2000 mm chamber. Its 27 kW heating power and 3-phase connection place it at the large end of the KTR series, above the KTR 1500 and below the KTR 22500. It serves as a high-throughput batch oven for preheating, drying, or tempering loads that fit the tall chamber format.
Nabertherm KTR Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Max temperature, °C |
|---|---|---|---|
| KTR 3100 Current | 3100 | 3-phase | 260 |
| KTR 6250 | 6250 | 3-phase | 260 |
Full specifications
| Chamber volume | 3100 l |
| Electrical connection | 3-phase |
| Heating power in kW1 mfr | 27 |
| Inner dimensions (W × D × H) mfr | 1250 × 1250 × 2000 mm |
| Outer dimensions (W × D × H) mfr | 2115 × 1680 × 2960 mm |
| Max temperature | 260 °C |
Description
Construction and series positioning
- The KTR 3100 is the 3100-litre member of the KTR chamber oven line, which also includes the KTR 1500, KTR 6125, KTR 6250, and KTR 22500. Chamber geometry is 1250 mm wide × 1250 mm deep × 2000 mm high, giving a tall, near-cubic working volume suited to vertically stacked or hanging loads.
- Outer dimensions are 2115 × 1680 × 2960 mm (W × D × H), so the unit requires substantial floor area and headroom; plan for access to the full chamber height during loading.
- Heating is electric with a 27 kW installed heating power on a 3-phase supply, and the maximum working temperature is 260 °C.
Behavior and media
- The 260 °C ceiling defines the process window; the KTR series is catalogued as chamber ovens up to 260 °C, distinct from the TR ovens (up to 300 °C) and WK heating cabinets (up to 150 °C) in the same catalogue section.
- LS variants with safety technology per EN 1539 exist for TR and KTR models; the KTR 3100 as specified here carries no such designation, so solvent-bearing or combustible-charge processes should not be assumed without confirming the safety configuration.
Control and operation
- Nabertherm's standard controller series 500 and the MyNabertherm app are the documented control platform across the range; process data storage and AMS2750F instrumentation types are addressed in the controller documentation, but no KTR 3100-specific control configuration is printed in the available digests.
- No curve points, certificates, or application data were supplied for this model; performance figures beyond the nameplate values above should be requested from the factory.
Integration & Operating Notes
The 27 kW heating power on a 3-phase connection implies a supply and protection scheme sized for the full heating load, not just the controller and fan. Confirm the site's available three-phase capacity and cable cross-section before installation; the unit cannot be run from a single-phase or shared lighting circuit.
The maximum temperature of 260 °C is the upper bound for every charge and program. Processes requiring 300 °C belong to the TR oven line, and 900 °C work to the NAT/NA forced-convection chamber furnaces; do not attempt to extend the KTR 3100 setpoint to cover such duties.
Safety technology per EN 1539 is offered as an LS variant on TR and KTR models, and the KTR 3100 as specified carries no LS designation. If the load releases solvents or flammable vapours, the standard chamber is not the correct configuration; specify the LS version instead of adding ad-hoc ventilation.
The available controller documentation covers Nabertherm series 500 and the MyNabertherm app, including process data storage and AMS2750F instrumentation types, but prints no KTR 3100-specific wiring or option list. Obtain the model-specific connection diagram and option sheet from the factory before designing signal interfaces.
Selection & Integration Q&A
Pick the KTR 3100 when the load needs roughly 3 m³ in a tall 1250 × 1250 × 2000 mm chamber at up to 260 °C. The KTR 1500 suits smaller batches; the KTR 22500 is for much larger volumes. Confirm charge geometry against the chamber height before deciding.
The 27 kW heating power on a 3-phase connection sets the supply, cable, and protection sizing; the controller and fan draw are secondary. Verify the site's three-phase capacity and breaker rating against the model-specific connection data from the factory before installation.
The supplied documents list no maintenance intervals, spare parts, or included accessories for the KTR 3100. Controller options, recorders, and AMS2750F instrumentation are catalogued separately from the oven, so request the model-specific option list and service schedule from Nabertherm.