Nabertherm L(T) 5/12
Nabertherm ·Made in Germany · In Active Production

Nabertherm L(T) 5/12

Nabertherm L(T) 5/12 — Muffle furnaces.

The L(T) 5/12 is a 5-litre muffle furnace with a 1200 °C maximum working temperature and a 2.6 kW single-phase heating system. Its 205 × 170 × 130 mm chamber and 59-minute heating time position it as the smallest 1200 °C modification in the Nabertherm L(T) series, suited to laboratory batch firing, ashing and heat-treatment of small samples.

Full specifications

Core Performance & Functional Specifications
Chamber volume 5 l
Electrical connection 1-phase
Nominal power 2.6 kW
Temperature uniformity 170 °C
Heating time mfr 59 min
Inner dimensions (W × D × H) mfr 205 × 170 × 130 mm
Outer dimensions (W × D × H) mfr 385 × 390 mm
Dimensions, Weight & Mechanical Design
Weight 27 kg
Operating Conditions, Environment & Protection
Max temperature 1200 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Electrical
Single-phase 2.6 kW load must be assigned to a dedicated circuit

At 2.6 kW on a single-phase connection the furnace draws a substantial current for a benchtop unit; the supply circuit, protective device and cable cross-section must be sized for this load and the unit should not share a circuit with other high-draw laboratory equipment.

Factory Specification Sheet
Process Limits
Chamber uniformity of 170 °C limits valid sample placement

The 170 °C temperature-uniformity figure means that parts of the chamber can deviate substantially from the setpoint; samples requiring tight thermal tolerance must be positioned in the verified uniform zone or the process must be qualified with a test load before use.

Factory Specification Sheet
Control & I/O
Controller and data-logging capability depends on ordered option

The controller documentation covers 500-series controllers and the MyNabertherm app with process-data storage and AMS2750F instrumentation types, but the base furnace delivery configuration is not stated; the required controller, program memory and recording functions must be confirmed at order.

Prozesssteuerung englisch (Process Control) brochure
Maintenance
No model-specific maintenance interval is documented

The verified documents contain no service schedule for the L(T) 5/12; maintenance intervals, thermocouple replacement and element inspection must be taken from the furnace operating manual supplied with the unit rather than assumed from this card.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the L(T) 5/12 rather than a larger chamber in the same 1200 °C series?

Choose the 5/12 when sample batches fit within 205 × 170 × 130 mm and the 59-minute heat-up is acceptable; larger siblings trade bench space and power for capacity, so the 5-litre unit is the right pick only for small, frequent batches.

What supply and control infrastructure does the L(T) 5/12 require?

It needs a single-phase supply sized for the 2.6 kW load on its own circuit. Controller, program memory and data logging are not fixed by the verified facts; confirm the 500-series controller or MyNabertherm option at order.

What is included in base delivery and what must be ordered separately?

The verified facts do not define the base scope; controller type, recording software and thermocouples appear as options in the controller documentation, so accessories and consumables must be confirmed against the order configuration.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF