Nabertherm LH 30/12
Nabertherm LH 30/12 — High-temperature furnaces.
The LH 30/12 is a 30-litre chamber furnace with brick insulation, rated to 1200 °C and connected via a 3-phase supply. Its 320 × 320 × 320 mm chamber and 200 kg brick-lined body distinguish it from fiber-insulated siblings such as the LH 30/14. It serves laboratory heat treatment, sintering and annealing where stable, uniform chamber temperature matters more than fast cycling.
Full specifications
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Electrical connection | 3-phase2 |
| Electrical connection | 3-phase2 |
| Electrical connection | 3-phase2 |
| Electrical connection | 3-phase2 |
| Electrical connection | 3-phase2 |
| Connected mfr | 7 |
| Inner dimensions (W × D × H) mfr | 320 × 320 × 320 mm |
| Outer dimensions (W × D × H) mfr | 710 × 930 × 1290 mm |
| Weight | 200 kg |
| Weight | 200 kg |
| Weight | 200 kg |
| Weight | 200 kg |
| Weight | 200 kg |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- The LH 30/12 is the 30-litre, 1200 °C member of Nabertherm's LH chamber furnace line; the '30' denotes chamber volume, not a rating.
- Brick insulation (LH series) is the heavier, thermally stable construction; fiber-insulated siblings (LF 60/14) and higher-temperature LH variants (LH 30/14, LH 120/12, LH 216/12) trade chamber size or maximum temperature against this balance.
- Chamber dimensions are 320 × 320 × 320 mm inside a 710 × 930 × 1290 mm outer envelope; the 200 kg weight reflects the brick lining.
Thermal behaviour
- Maximum working temperature is 1200 °C; no heating-curve or uniformity data are available for this model, so cycle design must be validated empirically.
- The cubic chamber and brick mass favour slow, uniform heating rather than rapid ramping; no forced-convection or atmosphere option is documented here.
Electrical and control
- The electrical connection is listed as 3-phase; the 'Connected' value of 7 in the factory data carries no unit and is not used as a power rating.
- Controller and process-control details are not model-specific in the supplied documents; the Nabertherm 500-series controller and MyNabertherm app are referenced only generically.
Integration & Operating Notes
The furnace is specified for a 3-phase connection, but the supplied data give no current or power figure (the 'Connected: 7' entry has no unit). The site electrician must obtain the nameplate rating and size the feeder, breaker and earth leakage protection accordingly before commissioning.
At 200 kg and 1290 mm tall, the unit needs a level floor rated for the point load and sufficient free space above and around the casing for heat dissipation and door swing. No specific clearance values are given in the supplied documents, so the installation manual must be consulted.
The maximum temperature is 1200 °C. Operating above it risks damage to the brick lining and heating elements. No overshoot allowance or uniformity tolerance is documented for this model, so the controller setpoint and safety limit should be configured below this ceiling.
The supplied process-control document covers the Nabertherm 500-series controllers and MyNabertherm app generically, without LH 30/12-specific parameters. Selection of controller, thermocouple type and any AMS2750F instrumentation class must be confirmed against the order configuration.
Selection & Integration Q&A
Pick the LH 30/12 for 30-litre loads up to 1200 °C where brick insulation's thermal stability suits slow, uniform cycles. The LH 30/14 offers the same volume at higher temperature; the LH 120/12 and LH 216/12 are for larger batches.
The unit is a 3-phase load, but the supplied data give no current or power rating (the 'Connected: 7' value has no unit). Take the nameplate figure and size feeder, breaker and earth leakage protection from it before commissioning.
Plan for a level floor rated for the 200 kg point load and 1290 mm height, with free space for casing heat dissipation and door swing. The supplied documents give no numeric clearance values, so follow the installation manual.
The supplied documents do not define a base-delivery bill of materials. Controller, thermocouple and recorder options are described only generically in the process-control document, so confirm the ordered configuration and any extra cables or consumables with the supplier.