The LHT 04/17 SW is a 4-litre high-temperature furnace with a 150 × 150 × 150 mm chamber, rated to 1750 °C and heated by a 3-phase connection. It is the SW (special) modification of the LHT 04/17 series, intended for combustion-loss determination and thermogravimetric analysis where a small, fast-cycling chamber is required.
Full specifications
| Chamber volume | 4 l |
| Electrical connection | 3-phase3 |
| Connected mfr | 5 |
| Heating time mfr | 30 min |
| Inner dimensions (W × D × H) mfr | 150 × 150 × 150 mm |
| Outer dimensions (W × D × H) mfr | 655 × 370 × 890 mm |
| Weight | 85 kg |
| Max temperature | 1750 °C |
Description
Construction and series positioning
- Chamber volume 4 l; inner dimensions 150 × 150 × 150 mm; outer dimensions 655 × 370 × 890 mm; weight 85 kg.
- Maximum temperature 1750 °C; heating time 30 min to reach working temperature.
- Electrical connection: 3-phase, 5 connected (as printed in the factory data). No sibling models are listed for this series, so the SW modification stands as the only documented variant here.
Thermal behaviour
- No digitized curve points are available; the only thermal data are the 1750 °C maximum and the 30 min heating time. The small 4-litre chamber and 150 mm cube geometry favour rapid heat-up and short recovery between TGA/combustion-loss runs, but no rate or uniformity figures are published in the verified facts.
Control and operation
- The attached controller document covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it does not print model-specific wiring or setpoints for the LHT 04/17 SW. No furnace-specific control configuration is confirmed by the supplied documents.
- The remaining attached digests (fiber-optics glass, foundry, dental) cover other product lines and contain no actionable facts for this model.
Integration & Operating Notes
The factory data list a 3-phase connection with 5 connected conductors. The electrical installer must confirm the site supply matches this configuration before commissioning; no voltage or current rating is printed in the verified facts, so the nameplate must be consulted.
The maximum temperature is 1750 °C. Operation above this limit risks damage to the heating elements and insulation; the controller setpoint and over-temperature protection must be configured so the chamber cannot exceed this value.
Selection & Integration Q&A
No sibling models are listed in the verified facts, so a direct comparison cannot be made. The SW is documented as a 4-litre, 1750 °C, 3-phase unit; confirm chamber size and electrical supply against any alternative before selecting.
The factory data specify a 3-phase connection with 5 connected conductors. Voltage and current are not printed in the verified facts, so the installer must read the nameplate and provide a matching three-phase supply before commissioning.
The verified facts contain no maintenance intervals, consumables or included accessories for the LHT 04/17 SW. The attached controller document covers the 500 series and MyNabertherm app but does not list furnace-specific service parts; these must be requested from the manufacturer.