Nabertherm NA 2000/45 LS — Forced Convection.

The NA 2000/45 LS is a forced-convection chamber furnace with a 1100 × 1500 × 1200 mm working chamber and 450 °C maximum temperature, built to EN 1539 safety technology for solvent-laden loads. Its 250-unit exhaust air flow and graduated solvent limits distinguish it from non-LS NA variants, making it suitable for drying and heat treatment where flammable volatiles are released.

Full specifications

Core Performance & Functional Specifications
Heating power 72 watt
Heating power 72 watt
Exhaust air flow rate mfr 250
Inner dimensions (W × D × H) mfr 1100 × 1500 × 1200 mm
Outer dimensions (W × D × H) mfr 2115 × 2650 × 2575 mm
Operating Conditions, Environment & Protection
Max temperature 450 °C
Max temperature 450 °C

Description

Construction and series positioning

Behavior with solvent loads

Control and documentation

Integration & Operating Notes

Process Limits
Solvent charge must be limited per temperature setpoint

The admissible solvent mass decreases with temperature, from 172 g down to 18 g across the listed range. Exceeding the limit for the actual chamber temperature risks exceeding the safe solvent concentration in the exhaust stream, so the batch recipe must be checked against the limit at every ramp segment, not only at the final setpoint.

Factory Specification Sheet, solvent limit table
Process Limits
Exhaust flow of 250 must be maintained during solvent operation

The solvent limits are tied to the stated exhaust air flow rate of 250. Ducting, extraction fans or building ventilation connected to the furnace outlet must sustain this flow; a restricted or shared exhaust path invalidates the solvent rating and is a safety issue, not merely a performance loss.

Factory Specification Sheet, exhaust air flow rate
Electrical
Confirm heating power and supply data on the order sheet

The specification lists 72 W heating power, which is not consistent with a 2000-litre 450 °C chamber and should be treated as a data-entry artifact. The actual connected load, voltage and phase must be taken from the order-specific nameplate before preparing the power supply and protection devices.

Factory Specification Sheet, heating power
Control & I/O
Controller and recorder are separate selections

The 500-series controller and MyNabertherm app functions, including process data storage and AMS2750F instrumentation types, are documented as controller options rather than furnace-integrated defaults. Specify the required controller, recorder and uniformity class at ordering; retrofitting instrumentation later changes the validation basis.

Prozesssteuerung englisch, controller functions and instrumentation types

Selection & Integration Q&A

When should I choose the NA 2000/45 LS rather than a non-LS NA forced-convection furnace of similar chamber size?

Choose the LS version when the charge releases flammable solvents during heating: it carries EN 1539 safety technology and a documented temperature-dependent solvent limit (172 g down to 18 g) with a 250 exhaust flow. For solvent-free loads, a non-LS NA model avoids the exhaust and solvent-limit constraints.

What exhaust and ventilation provisions must be in place before commissioning?

The exhaust path must sustain the stated flow rate of 250 continuously during solvent operation, since the solvent limits are tied to it. Ducting, extraction fan capacity and any building ventilation interface should be sized and verified before the first solvent-containing batch is run.

Which control and documentation items are not part of the base furnace delivery?

The 500-series controller functions, MyNabertherm app connectivity, process data storage, AMS2750F uniformity instrumentation and recorder options are documented as selectable controller and instrumentation options. They must be specified at ordering; the furnace alone does not include them.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF