Nabertherm NA 500/45
Nabertherm NA 500/45 — Forced Convection Furnaces.
The NA 500/45 is a 500-litre forced-convection chamber furnace with a 450 °C maximum temperature, electrically heated and connected to a 3-phase supply. Its 750 × 1000 × 750 mm chamber and 90-minute heat-up time position it as the mid-capacity air-circulation unit in the NA series, between the smaller NA 60/65 and NA 120/65 and the larger NA 250/85. It is intended for batch processes requiring uniform low-temperature heating with forced air movement.
Nabertherm NA Series — Model Comparison & Selection
Full specifications
| Chamber volume | 500 l |
| Chamber volume | 500 l |
| Chamber volume | 500 l |
| Chamber volume | 500 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 18 |
| Heat-up time3 mfr | 90 |
| Cool-down time3 from Tmax mfr | 45 |
| Inner dimensions (W × D × H) mfr | 750 × 1000 × 750 mm |
| Outer dimensions (W × D × H) mfr | 1400 × 1910 × 1810 mm |
| Weight | 800 kg |
| Weight | 800 kg |
| Weight | 800 kg |
| Weight | 800 kg |
| Max temperature | 450 °C |
| Max temperature | 450 °C |
| Max temperature | 450 °C |
| Max temperature | 450 °C |
Description
Construction and series positioning
- The NA 500/45 is a forced-convection chamber furnace with a 500 l working volume and inner chamber dimensions of 750 mm width × 1000 mm depth × 750 mm height.
- Outer dimensions are 1400 × 1910 × 1810 mm (W × D × H), and the unit weighs 800 kg.
- Within the NA series, the 500/45 is the mid-capacity model: the NA 60/65 and NA 60/85 are smaller, the NA 120/65 and NA 250/85 are intermediate, and the 500/45 offers the largest chamber among the listed siblings. The series is catalogued as forced convection chamber furnaces up to 675 litres, electrically heated.
- Heating is electric with a 3-phase connection; the maximum operating temperature is 450 °C.
Thermal behaviour
- Heat-up time to working temperature is stated as 90 (unit as printed in the factory data).
- Cool-down from Tmax is listed twice in the factory data (240 and 45, units as printed); because the two values conflict, neither is asserted here as the model's cooling performance.
- No digitized curve points were supplied, so no load-dependent or media-dependent behaviour can be quantified beyond the stated maximum temperature and heat-up time.
Control and operation
- The attached controller documentation covers the Nabertherm standard controller series 500 and the MyNabertherm app, including process data storage and temperature uniformity instrumentation per AMS2750F, but it does not print model-specific wiring or setpoints for the NA 500/45.
- No furnace-specific installation, connection or operating instructions for this model were found in the supplied document digests; the catalog section covering NAT/NA forced convection furnaces up to 900 °C confirms the product family but gives no NA 500/45-specific procedures.
Integration & Operating Notes
The verified electrical connection is 3-phase. No voltage, frequency, current or power rating is given in the supplied facts, so the site supply must be confirmed against the nameplate before installation; do not assume a 400 V/50 Hz supply from the series alone.
The maximum temperature is 450 °C. Operating above this limit is outside the verified specification and risks damage to the heating and air-circulation system; process recipes must be set with this ceiling in mind.
Selection & Integration Q&A
Choose the NA 500/45 when the batch needs the 500 l chamber (750 × 1000 × 750 mm) at up to 450 °C. The NA 250/85 and NA 120/65 are smaller siblings; the supplied facts give no temperature or volume data for them, so compare their nameplates before deciding.
A 3-phase supply is required; the verified facts give no voltage, frequency or current, so confirm against the nameplate. The controller is not defined in the supplied data: series 500 controllers and MyNabertherm app functions are documented separately and must be ordered as part of the control specification.
The supplied facts contain no maintenance schedule, service intervals or consumables list for the NA 500/45, and no accessories are stated as included. Controller options, recorders and AMS2750F instrumentation described in the controller document are separate items; confirm the delivery scope with the order documentation.