Nabertherm NT 200 DB.. — Furnace Solutions 1400 Degc.

The NT 200 DB.. is a 140-litre chamber furnace with a 1280 °C maximum working temperature and 3-phase electrical connection, built for single-zone heating control at 15 kW. Its 400 × 530 × 720 mm chamber and 500 kg mass place it as a mid-size batch unit for heat-treatment tasks below 1300 °C.

Full specifications

Core Performance & Functional Specifications
Chamber volume 140 l
Electrical connection 3-phase
Heating power for single-zone heating control mfr 15
Inner dimensions (W × D × H) mfr 400 × 530 × 720 mm
Outer dimensions (W × D × H) mfr 850 × 1350 × 2220 mm
Dimensions, Weight & Mechanical Design
Weight 500 kg
Operating Conditions, Environment & Protection
Max temperature 1280 °C

Description

Construction and series position

Thermal behaviour

Control and documentation

Integration & Operating Notes

Electrical
Plan a 3-phase feed sized for 15 kW heating power

The furnace is a 3-phase load with 15 kW of single-zone heating power. The site supply, protective device and cable cross-section must be selected for that connected load; no single-phase operation is described for this model.

Factory Specification Sheet
Process Limits
Keep the charge at or below 1280 °C

The maximum working temperature is 1280 °C. Process setpoints, over-temperature protection settings and any connected controller limits must be set below this value; the 1400 °C figure in the category path is the family ceiling, not this model's rating.

Factory Specification Sheet
Control & I/O
Controller and recorder scope must be fixed at order

The controller documentation covers the 500-series controllers, MyNabertherm app, process-data storage and AMS2750F instrumentation types, but does not tie any of them to this furnace code. Confirm which controller, recorder and instrumentation type are included before specifying data-logging or qualification requirements.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the NT 200 DB.. rather than another furnace in the 1400 °C family?

Pick it when the process stays at or below 1280 °C and a 140 l chamber of 400 × 530 × 720 mm suits the batch. If the work requires temperatures up to 1400 °C, this model's 1280 °C limit rules it out and a higher-rated family member is needed.

What supply and protective equipment does the 3-phase, 15 kW connection require?

The furnace is a 3-phase load with 15 kW single-zone heating power. The feed, protective device and cable must be sized for that connected load; no single-phase variant is described, so the installation must provide a 3-phase supply at the furnace location.

Which controller, recorder and data-logging items are included with the NT 200 DB..?

The controller digest describes 500-series controllers, MyNabertherm app, process-data storage and AMS2750F instrumentation types but prints no furnace model codes, so the included controller and recorder scope must be confirmed at order; do not assume data logging is in the base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF