Nabertherm RD 30/200/11
Nabertherm RD 30/200/11 — Tube furnaces.
The RD 30/200/11 is a compact 1-phase tube furnace with a 30 mm inner tube diameter and 200 mm heated length, rated to 1100 °C. Its 65 mm constant-temperature zone and 20-minute heating time distinguish this small-bore modification within the Compact Tube Furnaces series. It is intended for laboratory-scale thermal processing of small samples in a controlled atmosphere or ambient air.
Full specifications
| Electrical connection | 1-phase |
| Inner tube Ø mfr | 30 |
| Connected mfr | 1.7 |
| Heating time mfr | 20 min |
| Outer dimensions (W × D × H) mfr | 350 × 210 × 350 mm |
| Weight | 10 kg |
| Heated length mfr | 200 |
| Length constant mfr | 65 |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The RD 30/200/11 is the smallest-bore, shortest-heated-length configuration in the Nabertherm Compact Tube Furnaces series, with a 30 mm inner tube diameter and 200 mm heated length.
- The 65 mm length constant defines the axial zone over which temperature uniformity is maintained; this is the shortest constant zone in the series, suited to small specimens rather than long continuous profiles.
- The furnace weighs 10 kg and measures 350 × 210 × 350 mm (W × D × H), making it a bench-top unit that can be placed close to analytical instrumentation.
- Electrical connection is 1-phase; the connected load is 1.7 (as listed in the factory specification) and the maximum temperature is 1100 °C.
Thermal behavior
- Heating time to maximum temperature is stated as 20 min, so the unit reaches its 1100 °C ceiling quickly; this favors short-cycle laboratory work over large thermal mass.
- No digitized curve points are available for this model, so no cooling-rate or load-dependent gradient data can be asserted.
- The 30 mm bore limits the sample diameter; the 200 mm heated length and 65 mm constant zone mean that only the central portion of a workpiece sees the specified uniformity.
Control and operation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; these are controller-platform facts, not model-specific delivery content.
- No model-specific manual digest is available for the RD 30/200/11; installation, connection and operating specifics beyond the factory specification cannot be stated from the supplied documents.
Integration & Operating Notes
The furnace is a 1-phase unit with a connected load listed as 1.7 in the factory specification. The supply circuit, protective device and any upstream transformer must be rated for this load plus margin; the specification does not state the voltage, so the actual supply voltage must be confirmed against the nameplate before installation.
The maximum temperature is 1100 °C. Operation above this ceiling risks element failure and invalidates any uniformity assumption; the 20-minute heating time is quoted to this limit, so ramp programs should be checked against it rather than assumed.
The inner tube diameter is 30 mm, so samples, boats and thermowells must fit within this bore with clearance for the tube wall and any gas flow. The 65 mm length constant means only the central axial zone should be used for work requiring the stated uniformity.
Selection & Integration Q&A
Choose the RD 30/200/11 when samples fit within a 30 mm bore and the work must sit inside a 65 mm constant zone; its 200 mm heated length and 20-minute heating time suit short laboratory cycles. A larger bore or longer heated length is needed for bigger parts or longer uniform profiles.
It is a 1-phase unit with a 1.7 connected load, so the branch circuit and protective device must be sized accordingly; the specification does not state the voltage, so confirm it on the nameplate. The work tube must match the 30 mm inner diameter and be rated above 1100 °C.
The supplied documents list no model-specific maintenance interval, spare-parts kit or included accessories. Work tubes, thermocouples, gas fittings and controller options are not stated as part of the base delivery; these must be ordered separately and the service schedule confirmed with the manufacturer.