Nabertherm RHTH 80/300/..
Nabertherm ·Made in Germany · In Active Production

Nabertherm RHTH 80/300/..

Nabertherm RHTH 80/300/.. — Tube furnaces.

The RHTH 80/300/.. is a horizontally or vertically operable high-temperature tube furnace accepting tubes up to 80 mm outer diameter, with a 300 mm heated length and 1700 °C maximum temperature. Its 9.4 kW three-phase connection and 90 kg frame distinguish it from the larger RHTH 120/600/.. sibling. It serves controlled-atmosphere or air processing of small-diameter tubular workloads requiring a defined 100–150 mm constant-temperature zone.

Nabertherm RHTH Series — Model Comparison & Selection

Model Max temperature, °CWeight, kgElectrical connection
RHTH 80/300/.. Current 1700903-phase4
RHTH 120/600/.. 18001103-phase4

Full specifications

Core Performance & Functional Specifications
Electrical connection 3-phase4
Nominal power 9.4 kW
Max. outer tube Ø mfr 80
Outer dimensions (W × D × H) mfr 550 × 640 mm
Dimensions, Weight & Mechanical Design
Weight 90 kg
Heated length mfr 300
Tube length mfr 530
Operating Conditions, Environment & Protection
Max temperature 1700 °C

Description

Construction and series positioning

Thermal behavior and working zone

Control, connection and operation

Integration & Operating Notes

Process Limits
Keep the workload inside the 100–150 mm uniform band

The 300 mm heated length does not mean 300 mm of uniform temperature: the constant-temperature zone is 100 mm or 150 mm depending on the uniformity grade. Samples placed outside that band will see axial gradients, so the effective working length for qualified processes is the shorter uniform figure.

Factory Specification Sheet
Process Limits
Do not exceed 80 mm outer tube diameter

The furnace is built around a maximum outer tube diameter of 80 mm. Larger tubes will not fit the insulation and heating arrangement, and the 530 mm tube length must also be respected so that the tube ends clear the furnace body for seals and gas connections.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the RHTH 80/300/.. instead of the RHTH 120/600/..?

Pick the 80/300 when tube outer diameter stays at or below 80 mm and the qualified uniform zone of 100–150 mm is sufficient. The 120/600 sibling is the choice for larger tubes or longer uniform sections; it is a different frame, not an upgrade kit.

What electrical supply and protection does this furnace require?

A 3-phase/4-wire supply rated for the 9.4 kW nominal power, with a dedicated protected circuit and local isolator. Single-phase bench outlets are not suitable; the installer should size conductors and breakers for the full connected load.

Can I mount the furnace vertically in a fume hood?

The series permits horizontal or vertical operation, but the 90 kg mass and 550 × 640 mm footprint must be supported, and the tube seals and gas connections must be configured for the chosen orientation. Hood placement also depends on local exhaust and heat-dissipation requirements not stated in the supplied facts.

What must I order beyond the furnace itself to run a controlled-atmosphere process?

The supplied facts do not list a process tube, end seals, gas fittings or thermocouple feedthroughs in base delivery. Confirm the delivery scope with the order and separately procure an 80 mm max tube of 530 mm length plus seals suited to the gas or vacuum used.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF