Nabertherm RSRB 80/500/11
Nabertherm RSRB 80/500/11 — Tube furnaces.
The RSRB 80/500/11 is a rotary tube furnace for batch operation up to 1100 °C, with a 500 mm heated length and a tube outer diameter of 76 mm. It is the smaller of two series sizes, distinguished by its 500 mm heated zone and 3-phase electrical connection. It is used for thermal processing of granular or powdery solids in a rotating tube under controlled atmosphere.
Nabertherm RSRB Series — Model Comparison & Selection
| Model | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|
| RSRB 80/500/11 Current | 100 | 3-phase | 1100 |
| RSRB 120/750/11 | 120 | 3-phase | 1100 |
Full specifications
| Electrical connection | 3-phase |
| Max. outer mfr | 76 |
| Heated mfr | 500 |
| Connected mfr | 6.6 |
| Weight | 100 kg |
| Length constant mfr | 170 |
| Length constant mfr | 250 |
| Tube length mfr | 1140 |
| Ø Terminal mfr | 28 |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The RSRB 80/500/11 is a rotary tube furnace from Nabertherm's RSRB series, designed for batch operation up to 1100 °C.
- Within the series, it is the smaller model: the sibling RSRB 120/750/11 offers a larger tube and longer heated zone. The 80/500/11 is specified with a 500 mm heated length, a tube outer diameter of 76 mm, and a terminal diameter of 28 mm.
- The tube length is 1140 mm, with constant-temperature zones of 170 mm and 250 mm (likely at different ends or configurations). The unit weighs 100 kg and connects to a 3-phase supply with 6.6 kW connected load.
Behavior under load and media
- No digitized curve points are available for this model. The maximum working temperature is 1100 °C, and the rotary action is intended to ensure uniform exposure of batch material to the heated zone.
- The furnace is suitable for processing solids that require agitation to achieve uniform heating or reaction. The tube geometry (76 mm outer diameter) limits the batch size and particle size that can be processed.
Installation, control and operation
- The attached document digests do not contain specific installation or control details for this model. The controller series 500 and MyNabertherm app are mentioned in a general process control document, but no model-specific settings are provided.
- Electrical connection is 3-phase; the connected load is 6.6 kW. No voltage or frequency is specified in the verified facts, so the exact supply configuration must be confirmed with the manufacturer.
- The furnace is intended for batch operation; continuous or high-throughput use is not indicated by the available facts.
Integration & Operating Notes
The furnace is specified for 3-phase connection with a connected load of 6.6 kW. The verified facts do not state the operating voltage or frequency, so the site supply must be confirmed against the nameplate or manufacturer documentation before installation.
Operating above 1100 °C risks damage to the tube, heating elements, and insulation. The control system should be configured with an over-temperature limit to protect the furnace.
The tube has an outer diameter of 76 mm and a terminal diameter of 28 mm. The batch material must be compatible with the tube inner diameter and the rotary motion; oversized or agglomerating materials may cause blockages or uneven processing.
Selection & Integration Q&A
Choose the 80/500/11 for smaller batch volumes and when the 500 mm heated length and 76 mm tube diameter are sufficient. The 120/750/11 offers a larger tube and longer heated zone for higher throughput or larger parts.
The verified facts do not include a maintenance schedule. Consult the instruction manual for tube inspection, bearing lubrication, and heating element checks. Regular cleaning of the tube and seals is recommended for consistent operation.
The furnace is designed for batch operation up to 1100 °C. The tube material and seals may limit the use of certain atmospheres or corrosive substances. Verify compatibility with the manufacturer, especially for reducing or inert gases.