Nabertherm S 750
Nabertherm S 750 — Radiation Heating.
The S 750 is a top-loading radiation-heating furnace with a 750-litre chamber measuring 3000 × 500 × 500 mm, designed for long, narrow workloads. It reaches a maximum temperature of 1240 °C and is powered by a 3-phase electrical connection. Within the Top Loading Furnaces series, it is the elongated-chamber variant, distinguished from the shorter S 430 by its 3-metre internal width.
Full specifications
| Chamber volume | 750 l |
| Electrical connection | 3-phase |
| Heating power | 57 watt |
| Inner dimensions (W × D × H) mfr | 3000 × 500 × 500 mm |
| Outer dimensions (W × D × H) mfr | 3860 × 1500 mm |
| Weight | 2800 kg |
| Max temperature | 1240 °C |
Description
Construction and series positioning
- The S 750 is a top-loading furnace with a rectangular chamber of 3000 mm width, 500 mm depth and 500 mm height, giving a volume of 750 litres.
- Its external dimensions are 3860 mm wide and 1500 mm deep; the unit weighs 2800 kg.
- Compared with the sibling S 430, the S 750 is the extended-width modification intended for long workpieces or batch arrangements that cannot be accommodated in shorter chambers.
- Heating is by radiation from the chamber walls; the maximum working temperature is 1240 °C.
Electrical and thermal behaviour
- The furnace is connected to a 3-phase supply. The matched heating-power value (57 W) is not consistent with a 750-litre furnace at 1240 °C and is therefore not used in this overview.
- No digitized heating or cooling curves are available for this model; thermal behaviour under load cannot be quantified from the supplied facts.
- The chamber geometry (3000 × 500 × 500 mm) implies a high aspect ratio; temperature uniformity along the 3-metre length is not documented in the supplied digests.
Control and documentation
- The attached controller digest covers Nabertherm controller series 500 and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but does not print model-specific settings for the S 750.
- The remaining attached documents (fiber-optics glass, foundry, dental) describe other product lines and contain no S 750-specific installation or operating facts.
Integration & Operating Notes
The furnace is specified for a 3-phase connection, but the only heating-power figure in the fact set (57 W) is physically implausible for a 750-litre chamber at 1240 °C. The electrical designer must obtain the actual connected load and fuse rating from the factory specification sheet before sizing the supply and protective devices.
The unit weighs 2800 kg and occupies 3860 × 1500 mm externally. The installation floor must be assessed for the resulting distributed load, and access routes for moving the furnace into position must be checked against these outer dimensions before delivery.
With an internal height of 500 mm and depth of 500 mm, the usable cross-section is fixed; workpieces or fixtures taller than the chamber cannot be loaded. The 3000 mm width is the only extended axis, so loading plans should exploit length rather than height.
The controller digest describes series 500 functions, process-data storage and AMS2750F instrumentation types but prints no S 750-specific parameters. Control configuration, thermocouple type and recorder options must be confirmed against the furnace order documentation, not the generic controller brochure.
Selection & Integration Q&A
Choose the S 750 when the workload needs the 3000 mm chamber width; its 750-litre volume and 1240 °C limit suit long, low parts. The S 430 is the shorter sibling for smaller batches, but its key specs are not given here, so compare chamber dimensions before deciding.
The furnace is a 3-phase unit, but the only power figure supplied (57 W) is implausible for this size and cannot be used. Obtain the actual connected load and recommended fuse rating from the factory specification sheet before sizing cables and breakers.
The furnace weighs 2800 kg and measures 3860 × 1500 mm externally. Verify floor load capacity and that doors, corridors and lifting equipment can pass these dimensions; the supplied documents give no further siting clearances.
The supplied documents contain no S 750-specific maintenance schedule, service intervals or accessory list. Controller options are described only generically in the series 500 digest; consumables and cables must be confirmed with the order documentation.