Nabertherm SR(A) 90..
Nabertherm ·Made in Germany · In Active Production

Nabertherm SR(A) 90..

Nabertherm SR(A) 90.. — Hot Wall Retort Furnaces.

The SR(A) 90 is a pit-type hot-wall retort furnace with a 90-litre chamber and a maximum working temperature of 650 °C, powered by a 3-phase electrical connection. Its 1600 kg pit-mounted construction and 1400 × 2100 × 2600 mm outer envelope distinguish it as a floor-level batch unit for top-loading charge treatment below 650 °C.

Full specifications

Core Performance & Functional Specifications
Chamber volume 90 l
Electrical connection 3-phase
Outer dimensions (W × D × H) mfr 1400 × 2100 × 2600 mm
Dimensions, Weight & Mechanical Design
Weight 1600 kg
Operating Conditions, Environment & Protection
Max temperature 650 °C

Description

Construction and series positioning

The SR(A) 90 is a hot-wall retort furnace built as a pit-type unit: the 90-litre chamber is loaded from above and the complete furnace stands 2600 mm high with a 1400 × 2100 mm footprint. At 1600 kg it is a fixed-installation machine, not a benchtop or movable unit. Within the SR(A) series the 90-litre chamber is the defining size code; the maximum temperature of 650 °C places this modification in the lower-temperature range of the series (which extends up to 1100 °C), so it is selected where process temperature does not exceed 650 °C.

Thermal behaviour and media

No digitized curve points or cooling-rate data are available for this model, so heat-up and cool-down behaviour cannot be quantified from the supplied facts. The only thermal limit stated is the 650 °C maximum working temperature; operation above this value is outside the verified specification. The hot-wall retort arrangement means the retort wall is heated together with the charge, and the process atmosphere is contained by the retort rather than by the outer furnace structure.

Electrical and control

Electrical supply is 3-phase; no voltage, current or connected-load figure is stated in the verified facts, so the exact supply configuration must be taken from the nameplate or order documentation. Controller and process-data functions are covered by the separate Nabertherm controller documentation (series 500 and MyNabertherm app), which describes process data storage and temperature-uniformity instrumentation; that document does not print furnace model sizes, so controller fitment for this specific unit must be confirmed against the order.

Installation context

The pit-type format requires a floor opening or pit matching the 1400 × 2100 mm outer dimensions, with the 2600 mm height including the section below floor level. No mounting, clearance or foundation data are given in the verified facts; these must come from the installation drawing supplied with the unit.

Integration & Operating Notes

Mounting
Pit opening must match the 1400 × 2100 mm footprint

The furnace is a 1600 kg pit-type unit standing 2600 mm high; the floor opening and supporting structure must be built to the installation drawing so the furnace body is not loaded by the floor slab and the top edge sits at working level. No clearance figures are given in the verified facts, so do not size the pit from this card alone.

Factory Specification Sheet
Electrical
Confirm voltage and connected load from the nameplate

Only the 3-phase connection type is verified; voltage, frequency, current and connected load are not stated in the supplied facts. The supply, protective devices and cable cross-section must be sized from the nameplate and circuit diagram delivered with the furnace, not from generic series data.

Factory Specification Sheet
Process Limits
Do not exceed 650 °C retort temperature

The verified maximum temperature for this modification is 650 °C. Higher-temperature SR(A) variants exist in the series up to 1100 °C, but this 90-litre unit is specified to 650 °C only; running it hotter invalidates the specification and risks retort and charge damage.

Factory Specification Sheet
Control & I/O
Controller scope defined by separate controller documentation

The Nabertherm controller document covers series 500 functions, MyNabertherm app connectivity, process data storage and AMS2750F temperature-uniformity instrumentation types, but prints no furnace model codes. Verify which controller and recorder options are actually fitted to this unit against the order confirmation.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the SR(A) 90 rather than a higher-temperature SR(A) variant?

Choose the 90-litre unit when the charge fits a 90 l top-loaded chamber and the process stays at or below 650 °C. If the process requires temperatures up to 1100 °C, a higher-temperature SR(A) modification is needed instead; this unit is not rated above 650 °C.

What supply and upstream protection does the 3-phase connection require?

The verified facts state only a 3-phase connection; voltage, frequency and connected load are not given. Size the feeder, isolator and protective devices from the nameplate and circuit diagram supplied with the furnace, and have the supply installed by a qualified electrician.

What maintenance and accessories are defined for this model?

The verified facts contain no maintenance schedule, service intervals or accessory list for the SR(A) 90. Controller options are described only in the separate controller document without model codes, so consumables, cables and recorder fitment must be confirmed with the order documentation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF