Nabertherm SR(A) 90..
Nabertherm SR(A) 90.. — Hot Wall Retort Furnaces.
The SR(A) 90 is a pit-type hot-wall retort furnace with a 90-litre chamber and a maximum working temperature of 650 °C, powered by a 3-phase electrical connection. Its 1600 kg pit-mounted construction and 1400 × 2100 × 2600 mm outer envelope distinguish it as a floor-level batch unit for top-loading charge treatment below 650 °C.
Full specifications
| Chamber volume | 90 l |
| Electrical connection | 3-phase |
| Outer dimensions (W × D × H) mfr | 1400 × 2100 × 2600 mm |
| Weight | 1600 kg |
| Max temperature | 650 °C |
Description
Construction and series positioning
The SR(A) 90 is a hot-wall retort furnace built as a pit-type unit: the 90-litre chamber is loaded from above and the complete furnace stands 2600 mm high with a 1400 × 2100 mm footprint. At 1600 kg it is a fixed-installation machine, not a benchtop or movable unit. Within the SR(A) series the 90-litre chamber is the defining size code; the maximum temperature of 650 °C places this modification in the lower-temperature range of the series (which extends up to 1100 °C), so it is selected where process temperature does not exceed 650 °C.
Thermal behaviour and media
No digitized curve points or cooling-rate data are available for this model, so heat-up and cool-down behaviour cannot be quantified from the supplied facts. The only thermal limit stated is the 650 °C maximum working temperature; operation above this value is outside the verified specification. The hot-wall retort arrangement means the retort wall is heated together with the charge, and the process atmosphere is contained by the retort rather than by the outer furnace structure.
Electrical and control
Electrical supply is 3-phase; no voltage, current or connected-load figure is stated in the verified facts, so the exact supply configuration must be taken from the nameplate or order documentation. Controller and process-data functions are covered by the separate Nabertherm controller documentation (series 500 and MyNabertherm app), which describes process data storage and temperature-uniformity instrumentation; that document does not print furnace model sizes, so controller fitment for this specific unit must be confirmed against the order.
Installation context
The pit-type format requires a floor opening or pit matching the 1400 × 2100 mm outer dimensions, with the 2600 mm height including the section below floor level. No mounting, clearance or foundation data are given in the verified facts; these must come from the installation drawing supplied with the unit.
Integration & Operating Notes
The furnace is a 1600 kg pit-type unit standing 2600 mm high; the floor opening and supporting structure must be built to the installation drawing so the furnace body is not loaded by the floor slab and the top edge sits at working level. No clearance figures are given in the verified facts, so do not size the pit from this card alone.
Only the 3-phase connection type is verified; voltage, frequency, current and connected load are not stated in the supplied facts. The supply, protective devices and cable cross-section must be sized from the nameplate and circuit diagram delivered with the furnace, not from generic series data.
The verified maximum temperature for this modification is 650 °C. Higher-temperature SR(A) variants exist in the series up to 1100 °C, but this 90-litre unit is specified to 650 °C only; running it hotter invalidates the specification and risks retort and charge damage.
The Nabertherm controller document covers series 500 functions, MyNabertherm app connectivity, process data storage and AMS2750F temperature-uniformity instrumentation types, but prints no furnace model codes. Verify which controller and recorder options are actually fitted to this unit against the order confirmation.
Selection & Integration Q&A
Choose the 90-litre unit when the charge fits a 90 l top-loaded chamber and the process stays at or below 650 °C. If the process requires temperatures up to 1100 °C, a higher-temperature SR(A) modification is needed instead; this unit is not rated above 650 °C.
The verified facts state only a 3-phase connection; voltage, frequency and connected load are not given. Size the feeder, isolator and protective devices from the nameplate and circuit diagram supplied with the furnace, and have the supply installed by a qualified electrician.
The verified facts contain no maintenance schedule, service intervals or accessory list for the SR(A) 90. Controller options are described only in the separate controller document without model codes, so consumables, cables and recorder fitment must be confirmed with the order documentation.