Nabertherm TR 240
Nabertherm TR 240 — Laboratory ovens.
The TR 240 is a 240-litre electrically heated laboratory oven with a 300 °C maximum temperature and a 150 kg chamber load, powered by a 3.4 kW single-phase connection. Its 750 × 560 × 600 mm chamber and two grids distinguish it from smaller TR 120 and larger TR 1050 siblings in the series.
Nabertherm TR Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Load, kg | Weight, kg | Max temperature, °C |
|---|---|---|---|---|---|
| TR 240 Current | 240 | 1-phase | 150 | 145 | 300 |
| TR 450 | 450 | 3-phase | 180 | 200 | 300 |
Full specifications
| Chamber volume | 240 l |
| Chamber volume | 240 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Load capacity | 150 kilogram |
| Load capacity | 150 kilogram |
| Nominal power | 3.4 kW |
| Minutes mfr | 60 |
| Grids mfr | 7 |
| Inner dimensions (W × D × H) mfr | 750 × 560 × 600 mm |
| Outer dimensions (W × D × H) mfr | 1000 × 850 × 970 mm |
| Weight | 145 kg |
| Weight | 145 kg |
| Max temperature | 300 °C |
| Max temperature | 300 °C |
Description
Construction and series positioning
The TR 240 is a 240-litre chamber oven in Nabertherm's TR series, which the fiber-optics catalog section describes as ovens reaching up to 300 °C. Within the series, the TR 120 offers a smaller chamber and the TR 1050 a larger one; the TR 240 sits between them with a 750 × 560 × 600 mm inner chamber and a 1000 × 850 × 970 mm outer envelope. The unit weighs 145 kg and accepts a 150 kg load, so the chamber-to-load ratio is generous for a floor-standing laboratory oven.
Thermal behavior and media
Maximum temperature is 300 °C, consistent with the TR series ceiling cited in the fiber-optics catalog. No digitized curve points were supplied, so heat-up and uniformity behavior cannot be quantified here. The extra-spec field labeled "Minutes" with value 60 is not tied to a stated condition and is therefore not interpreted as a heat-up time. The chamber is fitted with two grids; a separate extra-spec value of 7 grids is not reconciled with the two-grid figure and is omitted from this description.
Electrical and control
Electrical connection is single-phase with a 3.4 kW nominal power. The controller documentation covers the Nabertherm 500 series and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but the digests do not state which controller is fitted to the TR 240 as delivered. Recorder and controller options are described only at series level.
Installation and operation
No installation, connection, or operating instructions specific to the TR 240 appear in the supplied document digests; the foundry, dental, and fiber-optics brochures are product-overview material. Mounting clearances, duty cycle, and maintenance intervals are therefore not stated in the verified facts and are not asserted here.
Integration & Operating Notes
The oven draws 3.4 kW on a single-phase connection. The engineer should confirm the branch circuit is sized for this load and reserved for the oven, since shared circuits on a 3.4 kW single-phase appliance leave little headroom for other equipment.
The stated load limit is 150 kg. Exceeding it risks damage to the chamber floor and grids and is outside the verified operating envelope; loads should be distributed across the two supplied grids rather than concentrated at one point.
The TR series is documented as reaching up to 300 °C, and the TR 240 shares that ceiling. Processes requiring higher temperatures fall outside this model and belong to other Nabertherm lines such as the KTR chamber ovens, which the catalog lists to 260 °C, or the NAT/NA furnaces to 900 °C.
Controller documentation covers the 500 series and MyNabertherm app with process-data storage and AMS2750F instrumentation types, but the supplied facts do not state which controller ships with the TR 240. The control configuration should be confirmed at order rather than assumed from the series brochure.
Selection & Integration Q&A
Pick the TR 240 when the 240-litre chamber (750 × 560 × 600 mm) and 150 kg load fit the batch but the TR 120 is too small and the TR 1050 is larger than needed. All three share the 300 °C TR ceiling; the choice is chamber size and load, not temperature.
A single-phase connection rated for the 3.4 kW nominal power. Because the load is single-phase, the branch circuit should be dedicated to the oven; the data sheet gives no other electrical interface details, so controller and recorder wiring must be confirmed against the ordered configuration.
No. The TR series ceiling is 300 °C and the chamber load limit is 150 kg. Higher-temperature work belongs to other Nabertherm lines (KTR to 260 °C, NAT/NA to 900 °C per the catalog), and loads above 150 kg exceed the verified limit.
The verified facts list two grids in the chamber; controller, recorder, and app options are described only at series level in the controller document, and no cables, consumables, or accessories are confirmed as included. These should be specified explicitly at order.