Nabertherm TR 450
Nabertherm ·Made in Germany · In Active Production

Nabertherm TR 450

Nabertherm TR 450 — Laboratory ovens.

The TR 450 is a 450-litre electrically heated laboratory oven with a 300 °C maximum temperature and 6.7 kW three-phase heating. Its 750 × 560 × 1100 mm chamber and 180 kg load capacity distinguish it from smaller TR 120 and larger TR 1050 siblings in the series. It serves general laboratory thermal processing where forced-convection uniformity and moderate batch volume are required.

Nabertherm TR Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionLoad, kgWeight, kgMax temperature, °C
TR 450 Current 4503-phase180200300
TR 240 2401-phase150145300

Full specifications

Core Performance & Functional Specifications
Chamber volume 450 l
Chamber volume 450 l
Electrical connection 3-phase
Electrical connection 3-phase
Load capacity 180 kilogram
Load capacity 180 kilogram
Nominal power 6.7 kW
Minutes mfr 45
Grids mfr 14
Inner dimensions (W × D × H) mfr 750 × 560 × 1100 mm
Outer dimensions (W × D × H) mfr 1000 × 850 × 1550 mm
Dimensions, Weight & Mechanical Design
Weight 200 kg
Weight 200 kg
Operating Conditions, Environment & Protection
Max temperature 300 °C
Max temperature 300 °C

Description

Construction and series positioning

Behavior and operating envelope

Control and documentation context

Integration & Operating Notes

Electrical
Three-phase supply must be sized for 6.7 kW continuous heating

The 6.7 kW nominal power on a three-phase connection determines breaker, contactor, and cable sizing; a single-phase supply is not compatible with this configuration. Confirm site voltage and phase balance before installation, and provide a dedicated protected circuit sized for the full heating load rather than the average duty.

Factory Specification Sheet
Process Limits
Chamber load must stay within 180 kg and 300 °C

Exceeding the 180 kg load rating risks damage to the chamber floor and shelf supports, while operation above 300 °C exceeds the model's maximum temperature. Both limits apply simultaneously; heavy loads at high temperature are the worst case for the internal structure and should be assessed together.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the TR 450 rather than the TR 120 or TR 1050 in the same series?

Pick the TR 450 when the batch needs roughly 450 l of chamber volume and up to 180 kg load at 300 °C. The TR 120 suits smaller loads; the TR 1050 suits larger batches. All share the 300 °C TR-series ceiling, so volume and load, not temperature, drive the choice.

What supply and protection does the TR 450 need from the building electrical system?

It requires a three-phase connection sized for the 6.7 kW nominal heating power. Provide a dedicated protected circuit rated for the full heating load, and confirm site voltage and phase balance before installation; a single-phase supply is not compatible with this configuration.

What controller documentation and accessories are not included with the base oven?

The controller digest covers series 500 functions and the MyNabertherm app but prints no TR 450-specific settings, so the order-specific controller manual and wiring diagram must be obtained separately. Recorder and controller options are documented as separate items, not part of the base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF