Nabertherm TR 450
Nabertherm TR 450 — Laboratory ovens.
The TR 450 is a 450-litre electrically heated laboratory oven with a 300 °C maximum temperature and 6.7 kW three-phase heating. Its 750 × 560 × 1100 mm chamber and 180 kg load capacity distinguish it from smaller TR 120 and larger TR 1050 siblings in the series. It serves general laboratory thermal processing where forced-convection uniformity and moderate batch volume are required.
Nabertherm TR Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Load, kg | Weight, kg | Max temperature, °C |
|---|---|---|---|---|---|
| TR 450 Current | 450 | 3-phase | 180 | 200 | 300 |
| TR 240 | 240 | 1-phase | 150 | 145 | 300 |
Full specifications
| Chamber volume | 450 l |
| Chamber volume | 450 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Load capacity | 180 kilogram |
| Load capacity | 180 kilogram |
| Nominal power | 6.7 kW |
| Minutes mfr | 45 |
| Grids mfr | 14 |
| Inner dimensions (W × D × H) mfr | 750 × 560 × 1100 mm |
| Outer dimensions (W × D × H) mfr | 1000 × 850 × 1550 mm |
| Weight | 200 kg |
| Weight | 200 kg |
| Max temperature | 300 °C |
| Max temperature | 300 °C |
Description
Construction and series positioning
- The TR 450 is the mid-volume member of the Nabertherm TR oven line, positioned between the TR 120 and the TR 1050 siblings. Chamber volume is 450 l with inner dimensions of 750 × 560 × 1100 mm (W × D × H) and outer dimensions of 1000 × 850 × 1550 mm.
- The unit is electrically heated with a 6.7 kW nominal power rating and a three-phase electrical connection. Maximum operating temperature is 300 °C, consistent with the TR series ceiling cited in the fiber-optics catalog section (TR ovens up to 300 °C).
- The 180 kg load rating and 200 kg unit weight define the floor or bench installation envelope; the tall 1550 mm outer height requires vertical clearance for door swing and top access.
Behavior and operating envelope
- No digitized curve points were supplied for this model, so heating-rate and uniformity behavior cannot be quantified from the available facts. The 300 °C maximum is the only confirmed thermal limit; operation above it is outside the model's rating.
- The extra-spec field labeled 'Minutes' with value 45 has no associated condition or parameter name and is therefore not interpreted here as a heating, ramp, or dwell time.
- The 'Grids' entries (3 and 14) are not tied to a labeled configuration in the supplied facts and are not asserted as the delivered shelf count.
Control and documentation context
- The attached controller digest covers Nabertherm controller series 500 and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no TR 450-specific settings. Controller configuration must be confirmed against the order-specific wiring and controller manual.
- The fiber-optics catalog section confirms that LS variants (safety technology per EN 1539) exist for TR models; the supplied facts do not state whether this TR 450 is an LS variant, so safety-technology compliance must be verified per unit.
Integration & Operating Notes
The 6.7 kW nominal power on a three-phase connection determines breaker, contactor, and cable sizing; a single-phase supply is not compatible with this configuration. Confirm site voltage and phase balance before installation, and provide a dedicated protected circuit sized for the full heating load rather than the average duty.
Exceeding the 180 kg load rating risks damage to the chamber floor and shelf supports, while operation above 300 °C exceeds the model's maximum temperature. Both limits apply simultaneously; heavy loads at high temperature are the worst case for the internal structure and should be assessed together.
Selection & Integration Q&A
Pick the TR 450 when the batch needs roughly 450 l of chamber volume and up to 180 kg load at 300 °C. The TR 120 suits smaller loads; the TR 1050 suits larger batches. All share the 300 °C TR-series ceiling, so volume and load, not temperature, drive the choice.
It requires a three-phase connection sized for the 6.7 kW nominal heating power. Provide a dedicated protected circuit rated for the full heating load, and confirm site voltage and phase balance before installation; a single-phase supply is not compatible with this configuration.
The controller digest covers series 500 functions and the MyNabertherm app but prints no TR 450-specific settings, so the order-specific controller manual and wiring diagram must be obtained separately. Recorder and controller options are documented as separate items, not part of the base delivery.