The DSC-60 Plus is a heat-flux differential scanning calorimeter with a measured temperature range of -140 to 600 °C and a calorimetric range of ±150 mW. It is the base, manual-loading member of the DSC-60 Plus Series, distinguished from the DSC-60A Plus by the absence of the 24-position autosampler. It is used to measure transition enthalpies and temperatures of materials under programmed heating and cooling.

Full specifications

Core Performance & Functional Specifications
Calorimetric range ±150 mW (DSC-60 Plus)
Measured temperature range -140 to 600 °C (DSC-60 Plus)
Autosampler capacity (DSC-60A Plus) mfr 24 samples/tray (DSC-60A Plus)
Autosampler capacity (DTG-60A / DTG-60AH) mfr 24 samples/tray (DTG-60A / DTG-60AH)
Dimensions, Weight & Mechanical Design
Weight 28 kg (DSC-60 Plus)
Weight (DSC-60A Plus) mfr 31 kg (DSC-60A Plus)
Weight (DTG-60 / DTG-60A) mfr 35 kg (DTG-60 / DTG-60A)
Weight (DTG-60H / DTG-60AH) mfr 40 kg (DTG-60H / DTG-60AH)
Electrical, Power & Drive Specifications
Power consumption (DTG-60 / DTG-60A, 50/60 Hz) mfr 1300 VA (DTG-60 / DTG-60A, 50/60 Hz)
Power consumption (DTG-60H / DTG-60AH, 50/60 Hz) mfr 1500 VA (DTG-60H / DTG-60AH, 50/60 Hz)
Operating Conditions, Environment & Protection
Noise level less than 0.5 μW (DSC-60 Plus)

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection and control

Integration & Operating Notes

Process Limits
Keep transition heat flow within ±150 mW

The calorimetric range is the full-scale heat-flow difference the instrument can record. Samples with large enthalpies at the chosen heating rate can saturate the signal; reduce sample mass or scan rate so the peak stays inside ±150 mW, otherwise the peak shape and onset temperature are invalid.

Factory Specification Sheet, DSC-60 Plus calorimetric range
Process Limits
Do not program temperatures outside -140 to 600 °C

The measured temperature range is the only operating window stated for this model. Exceeding either limit is outside the specified measurement range and risks invalid results or damage to the furnace and sensor; the cooling medium required to reach -140 °C is not described in the supplied digest.

Factory Specification Sheet, DSC-60 Plus measured temperature range
Maintenance
Obtain the full manual before defining service intervals

The attached document digest (c160-e006) contains no sections or actionable facts, so calibration, sensor cleaning and reference-material schedules are not available here. Request the complete instruction manual to set maintenance intervals and error-code handling before putting the unit into routine use.

Document digest c160-e006

Selection & Integration Q&A

When should I choose the DSC-60 Plus instead of the DSC-60A Plus?

Pick the DSC-60 Plus for manual sample loading and lower bench weight (28 kg). Choose the DSC-60A Plus when unattended runs of up to 24 samples per tray are needed; it weighs 31 kg and shares the same calorimetric platform.

Can I use the DTG-60 series as a backing stage for this DSC?

The DTG-60/60H/60A/60AH are separate TG/DTA instruments (ambient to 1100 or 1500 °C, 1300–1500 VA), not accessories of the DSC-60 Plus. They are listed as related models only; no coupled DSC-TG configuration is described in the supplied facts.

What environment and duty limits apply to the DSC-60 Plus installation?

Only the measurement window -140 to 600 °C and the 28 kg mass are specified. The supplied document digest has no sections on ambient conditions, cooling medium or duty cycle, so these must be confirmed from the full instruction manual.

What is included in base delivery and what must be ordered separately?

The supplied facts list no accessories, cables or consumables. The autosampler tray belongs to the DSC-60A Plus, not this model. Reference materials, cooling accessories and cables must be confirmed against the full manual and order list.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
c160-e006
Datasheet ·3,6 МБ ·12 pp.
View PDF