Shimadzu Kratos Nova
Shimadzu ·Made in Japan · In Active Production

Shimadzu Kratos Nova

Shimadzu Kratos Nova — Spectrometers.

The Kratos Nova is a fully automated imaging X-ray photoelectron spectrometer (XPS) configured with up to three 110 mm diameter sample platens and electron-only charge neutralisation. It delivers large-area spectroscopy over a 700 x 300 µm analysis area and parallel imaging with fields of view of ca. 950 x 950 µm, 425 x 425 µm and 220 x 220 µm. It is intended for spatially resolved surface chemical analysis of both conducting and insulating specimens in a multi-sample laboratory workflow.

Full specifications

Core Performance & Functional Specifications
Maximum sample thickness (deep sample platen) mfr 19 mm (deep sample platen)
Platen storage capacity (SEC storage elevator) mfr up to three platens (SEC storage elevator)
Platen elevator mfr 45 mm
XPS parallel imaging mfr 950 x
Performance on insulators mfr The AXIS Nova has an electron only charge neutra
Sample handling mfr 110 mm
Ion source mfr 4 monatomic
Standards, Safety & General Data
Excitation source (standard) mfr Al Ka (standard)
Information depth (standard Al Ka excitation source) mfr upper most 10 nm (standard Al Ka excitation source)

Description

Construction and positioning

Integration & Operating Notes

Sample Handling
Platen diameter is fixed at 110 mm for automated loading

The automated sample-introduction system is built around 110 mm diameter platens, and up to three can be loaded at one time. Specimens or sample holders must be mounted to suit this platen format; the supplied facts give no alternative carrier size, so mounting hardware should be planned around the 110 mm platen.

Factory Specification Sheet, Sample handling
Ion Source
Depth profiling requires the fitted Minibeam ion source option

Sample cleaning and sputter depth profiling depend on which ion source is fitted: the Minibeam 4 monatomic Ar+ source or the Minibeam 6 multi-mode Gas Cluster Ion Source (GCIS). The required source must be specified with the instrument; the supplied facts do not state that both are present simultaneously.

Factory Specification Sheet, Ion source

Selection & Integration Q&A

What sample carrier format must adjacent sample-preparation equipment support?

The automated introduction system accepts 110 mm diameter platens, up to three at a time. Preparation and mounting fixtures should therefore be sized for 110 mm platens; no other carrier format is described in the supplied facts.

What maintenance schedule and consumables are included with the base instrument?

No maintenance intervals, consumables, cables or accessories are defined in the supplied documents. The ion source (Minibeam 4 or Minibeam 6 GCIS) must be specified as part of the configuration; service items should be confirmed with Shimadzu directly.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
mo444a
Datasheet ·1,7 МБ ·5 pp.
View PDF