Shimadzu SPM 8100FM
Shimadzu SPM 8100FM — Microscopes.
The SPM 8100FM is a scanning probe microscope head using an optical lever displacement detection system with a laser diode and photodetector, supporting contact, dynamic (AM and FM), and lateral force modes. It achieves 0.2 nm horizontal and 0.01 nm vertical resolution, with the laser remaining on during sample exchange to maintain alignment. This modification is suited for nanoscale surface topography and force mapping where continuous optical access and multi-mode operation are required.
Full specifications
Description
Construction and positioning
- The SPM 8100FM is a contact/dynamic/LFM scanning probe microscope head built around a light-source–optical-lever–photodetector displacement detection system. - A laser diode (with ON/OFF control) irradiates the cantilever continuously, including during sample replacement, preserving optical alignment between measurements. ### Behavior under load and in different modes
- Three observation modes are supported: contact, dynamic (AM method and FM method), and lateral force (LFM). - Resolution is specified as 0.2 nm horizontally and 0.01 nm vertically, enabling sub-nanometer topographic and lateral-force mapping. - The photodetector-based optical lever requires stable laser diode operation; the continuous irradiation feature is intended to avoid re-alignment during sample exchange.
Integration & Operating Notes
Because the laser diode irradiates the cantilever continuously even while replacing samples, the head must be mounted so that sample exchange does not disturb the optical path; any mechanical drift in the head mount will directly affect the photodetector signal and require re-alignment.
Contact, dynamic (AM and FM), and lateral force modes impose different cantilever and feedback conditions; the user must ensure the probe and control settings match the selected mode, as the specification lists these modes but does not define cross-mode compatibility or automatic switching.
The laser diode can be switched off, which should be used when servicing the probe or detector area to avoid unnecessary exposure and to preserve diode lifetime; no maintenance interval is specified in the provided facts, so service scheduling must follow the instrument manual.
Selection & Integration Q&A
The laser remains on during sample exchange to preserve alignment, so the head must be mounted to avoid mechanical drift that would disturb the optical lever. No duty-cycle, environmental, or vibration limits are given in the provided facts; consult the manual.
No maintenance schedule, cables, or consumables are listed in the provided facts. The laser diode has ON/OFF control for safe servicing. Probe cantilevers and any control electronics are not stated as included; confirm the base delivery scope with the supplier.