Waters ACQUITY UPLC ELS Detector

Waters ACQUITY UPLC ELS Detector — Chromatography detectors.

The ACQUITY UPLC ELS Detector is a photomultiplier‑tube‑based evaporative light scattering detector with a front‑mounted, snap‑in nebulizer and a heated optics bench held at 50 °C. It supports flow rates up to 2 mL/min and a dynamic range of 0.1–2000 light scattering units full scale, with 0.1 °C temperature control and 0.1 s filter increments. It is used in UPLC systems for sensitive, universal detection of non‑volatile and semi‑volatile analytes.

Full specifications

Core Performance & Functional Specifications
Detector type Photomultiplier tube
Flow rate 2 mL/min
Nebulizer mfr Front mounted, snap-in design
Gas mfr Nitrogen, to be supplied, at least 65 psi
Temperature range drift tube mfr 0.1 °C increments, feedback accuracy to 0.1 °C
Filter setting mfr Hamming, 0 to 5.0 seconds in 0.1 second incremen
Optics mfr Heated optics bench (constant 50 °C)
Light source mfr Tungsten halogen polychromatic, front mounted, p
Range mfr 0.1 to 2000 light scattering units full scale
Dimensions, Weight & Mechanical Design
Width mfr 34.3 cm (13.5 inches)
Height mfr 21.6 cm (8.5 inches)
Depth mfr 51.8 cm (20.4 inches)
Electrical, Power & Drive Specifications
Voltage range mfr 0 to 1250 VDC

Description

Construction and positioning

Integration & Operating Notes

Process Limits
Nitrogen supply must be ≥65 psi and dry

The detector requires nitrogen at a minimum of 65 psi. Lower pressure or moisture/oil contamination will cause incomplete nebulization, baseline noise, and potential damage to the optics. Install a suitable regulator, filter, and gauge before the instrument.

Factory Specification Sheet
Electrical
PMT voltage up to 1250 VDC requires stable supply

The photomultiplier tube operates up to 1250 VDC. Ensure the instrument is connected to a stable, grounded power source free of surges; voltage fluctuations can affect gain stability and detector sensitivity.

Factory Specification Sheet
Control & I/O
Temperature and gas must be stable before data acquisition

Allow the drift tube and optics bench to reach set temperatures (optics at 50 °C) and verify nitrogen pressure before injecting samples. Starting acquisition before thermal equilibrium can cause baseline drift and invalid results.

Factory Specification Sheet
Maintenance
Nebulizer and light source are user‑replaceable

The front‑mounted, snap‑in nebulizer and pre‑aligned light source are designed for user installation. Follow the site’s preventive maintenance schedule for cleaning or replacement; no special tools are required for these items.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the ACQUITY UPLC ELS Detector instead of a UV or fluorescence detector?

Choose ELS for analytes lacking chromophores or fluorophores, or for universal detection of non‑volatile compounds. UV/fluorescence offer higher sensitivity for specific chromophores but require derivatization for many analytes.

What are the gas supply requirements and how do they affect integration with my UPLC system?

The detector needs nitrogen at ≥65 psi. Ensure a regulated, dry supply with adequate flow capacity; pressure drops during operation can cause nebulization instability and baseline noise, affecting detection limits.

What maintenance items and accessories are not included in the base delivery?

The base delivery does not include nitrogen gas supply components (regulator, filter, tubing) or replacement nebulizer/light source. These must be ordered separately; the nebulizer and light source are user‑installable.