Waters Alliance iS HPLC System - Analysis for Quality Control Labs
Waters ·Made in USA · In Active Production

Waters Alliance iS HPLC System - Analysis for Quality Control Labs

Waters Alliance iS HPLC System - Analysis for Quality Control Labs — Chromatographs with Flow rate 10 milliliter/minute, Max pressure 82.74 megapascal.

The Alliance iS HPLC System is an integrated quaternary HPLC platform with flow-through needle injection and stainless-steel flow path, supporting up to 10.0 mL/min and 12,000 psi. It distinguishes itself within the Alliance series by its integrated TUV or PDA detector options and RFID-enabled column tracking, targeting quality control laboratories that require high-throughput, reliable analysis with minimal carryover (≤0.002% caffeine).

Flow rate
10 milliliter/minute
Max pressure
82.74 megapascal

Full specifications

Core Performance & Functional Specifications
Flow rate 10.0 mL/min
Max pressure 12000 psi
Column temperature 40 °C
Injection type mfr Flow-through needle
Sample flow path mfr Stainless steel
Sample carryover mfr ≤0.002% [Caffeine] under UV conditions
Sample compartment mfr 4 to 40 °C
Pump options mfr Quaternary
Solvent conditioning mfr Passive pre-heating
Column tracking mfr Yes, with RFID enabled eConnect Waters Columns
Column capacity mfr 1 column up to 300 mm length, up to 8 mm interna
Maximum sample capacity mfr (any three of the following) 48-position, 2.00-m
Integrated Detector Options mfr TUV Detector, PDA Detector
External Detectors Supported mfr CAD, ACQUITY QDa II, ELS, RI, FLR, MALS
Informatics compatibility mfr Empower Chromatography Data System (CDS) (Featur
Dimensions, Weight & Mechanical Design
Height 742 mm
Weight 72.5 kg
Width 499 mm
Depth mfr 63.5 cm (24.99 in.)
Materials, Media & Process Compatibility
pH range mfr 1 to 13

Description

Construction and Positioning

Integration & Operating Notes

Control & I/O
Empower CDS FR4 with Windows 10 required for control

The system is controlled exclusively via Empower Chromatography Data System (Feature Release 4) running on Windows 10 or later. Ensure the PC meets Empower specifications and that network infrastructure supports instrument control and data transfer.

Factory Specification Sheet
Process Limits
Column length and I.D. limited to 300 mm and 8 mm

The column compartment accepts only one column up to 300 mm length and 8 mm internal diameter. Using larger columns may cause fit issues or performance degradation. Verify column dimensions before installation.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Alliance iS HPLC System with integrated TUV detector versus a configuration with PDA or external detectors?

Choose integrated TUV for routine QC assays with fixed wavelengths and simplicity. Choose integrated PDA for method development or peak purity. For specialized detection (e.g., mass spec, fluorescence), select a configuration without integrated detector and connect an external detector via the supported interfaces.

What are the requirements for connecting an external detector such as the ACQUITY QDa II to the Alliance iS?

The system supports external detectors including CAD, ACQUITY QDa II, ELS, RI, FLR, and MALS. Connection requires appropriate interface cables and configuration in Empower CDS. Ensure the detector's output range and communication protocol are compatible with the system's I/O.

What maintenance kits and consumables are recommended for the Alliance iS, and are they included in the base delivery?

The base delivery includes the system and standard accessories. Consumables such as pump seals, injector needles, and detector lamps are not included. Waters offers preventive maintenance kits; refer to the instruction manual for part numbers and replacement intervals.

Dimensional Drawings & Technical Documentation

Technical documentation