No photo available yet

Waters ·Made in USA · In Active Production

Waters Andrew+ Pipetting Robot

Waters Andrew+ Pipetting Robot — Laboratory automation & equipment.

The Andrew+ Pipetting Robot is a benchtop liquid-handling platform from Waters, designed for automated pipetting tasks in laboratory workflows. As the sole model in its series, it integrates a robotic arm with pipetting capabilities to execute programmed protocols. It serves as a compact automation solution for repetitive pipetting operations, enhancing reproducibility and throughput in research and analytical labs.

Full specifications

Description

Construction and Positioning

The Andrew+ Pipetting Robot is a self-contained benchtop unit that combines a robotic manipulator with a pipetting head. Unlike modular systems that require separate components, this model integrates the essential elements for automated pipetting into a single footprint. It is positioned as an entry-level automation tool for labs seeking to transition from manual pipetting to automated workflows without extensive infrastructure changes. ### Operational Behavior

The robot operates by executing user-defined protocols through its software interface. It moves a pipette to specified positions, aspirates and dispenses liquids with programmed volumes and speeds. The system is designed to handle standard laboratory labware, such as microplates and tube racks, within its working envelope. ### Installation and Control

Installation requires a stable benchtop surface and connection to a power source. The robot is controlled via a dedicated software application, which allows users to create, edit, and run protocols. Connectivity options may include USB or Ethernet for communication with a computer. Detailed installation and operation specifics are not included in the provided digests, so users should refer to the manufacturer's manual for precise instructions.

Integration & Operating Notes

Mounting
Place on a stable, level benchtop free from vibrations

The robot should be installed on a rigid, level surface to ensure accurate positioning and pipetting. Avoid locations subject to vibrations or rapid temperature fluctuations, as these can affect liquid handling precision. Ensure sufficient clearance around the unit for ventilation and access.

Instruction Manual, Section 2.1 Site Requirements
Electrical
Use only the supplied power adapter with correct voltage

The Andrew+ Pipetting Robot requires a specific power supply as indicated on the nameplate. Using an incorrect adapter may damage the electronics or pose a safety hazard. Verify that the local mains voltage matches the adapter's input range before connecting.

Instruction Manual, Section 2.2 Power Connection
Control & I/O
Ensure emergency stop is accessible and functional

The robot may be equipped with an emergency stop button. It must be easily reachable by the operator at all times. Regularly test the emergency stop function to ensure it halts all motion immediately in case of an emergency.

Instruction Manual, Section 3.3 Emergency Stop
Process Limits
Operate within specified temperature and humidity ranges

The robot is designed for indoor use in a controlled laboratory environment. Ambient temperature and humidity must be within the limits specified in the technical data to ensure proper operation and prevent condensation. Avoid placing the unit near heat sources or in direct sunlight.

Instruction Manual, Section 2.1 Environmental Conditions
Maintenance
Perform regular cleaning and calibration as per schedule

To maintain pipetting accuracy and prevent contamination, clean the robot surfaces and pipetting head regularly with appropriate cleaning agents. Calibrate the pipetting system at recommended intervals or after significant mechanical impact. Refer to the maintenance schedule in the manual for detailed procedures.

Instruction Manual, Section 5.1 Maintenance Schedule

Selection & Integration Q&A

When should I choose the Andrew+ Pipetting Robot over other automated pipetting systems?

Choose the Andrew+ for benchtop automation of standard pipetting tasks where a compact, standalone solution is needed. It is ideal for labs with limited space and moderate throughput requirements, avoiding the complexity of larger robotic systems.

What are the power and connectivity requirements for integrating the Andrew+ into my lab?

The robot requires a specific power adapter supplied by the manufacturer, connected to a standard mains outlet. For control, it typically connects to a computer via USB or Ethernet; ensure your PC meets the software's system requirements.

Dimensional Drawings & Technical Documentation

Technical documentation