Waters Aura Plus System

Waters Aura Plus System — Particle size analyzers.

The Aura Plus System is an imaging-based particle size analyzer with 4x and 20x objectives and a 1.0 pixel/µm spectral resolution, configured for 96-well and 24-well plate formats. It detects particles from >1 µm to <5 mm (96-well) or <14 mm (24-well) and reads a 96-well plate in about 1 minute per sample. It is used for automated particle sizing and morphological analysis in laboratory workflows.

Direct drop-in replacements

Shimadzu
Aggregates Sizer
0%
match
⚖️ Compare
Shimadzu
Ispect DIA 10
0%
match
⚖️ Compare
Shimadzu
SALD-2300
0%
match
⚖️ Compare
Shimadzu
SALD-7500nano
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Spectral resolution 1.0 pixel/µm
Imaging area mfr 24.6 mm 2 (96-well); 158.9 mm 2 (24-well)
Optics mfr 4x and 20x objectives
Minimum volume mfr 5 μL (assay dependent)
Detectable size range mfr From >1 μm (ECD) to <5 mm (ECD) on 96-well; <14
BMI read time mfr 1 minute/sample
FMM read time mfr 30 seconds/sample
Software mfr Particle VUE TM 5.x all-in-one software suite fo

Description

Construction and positioning

The Aura Plus System is a benchtop imaging particle analyzer that combines two magnifications (4x and 20x) with a large imaging area: 24.6 mm² for 96-well plates and 158.9 mm² for 24-well plates. The minimum sample volume is 5 µL, assay dependent. ### Measurement behavior

The system covers a detectable size range from >1 µm to <5 mm on 96-well plates and up to <14 mm on 24-well plates, using ECD (equivalent circular diameter) as the size metric. Spectral resolution is 1.0 pixel/µm. Read times are 1 minute per sample for BMI and 30 seconds per sample for FMM, enabling moderate-throughput plate-based analysis. ### Software and operation

All image acquisition and analysis are controlled by the Particle VUE™ 5.x all-in-one software suite, with an optional Security Pack for regulated environments.

Integration & Operating Notes

Process Limits
Sample volume must be at least 5 µL for reliable detection

The minimum volume is 5 µL, but this is assay dependent; lower volumes may not fill the imaging area adequately, leading to incomplete data. Verify that the assay volume meets or exceeds this threshold before running plates.

Factory Specification Sheet
Process Limits
Size range depends on plate format: 96-well vs 24-well

On 96-well plates the detectable size range is from >1 µm to <5 mm (ECD), while on 24-well plates it extends to <14 mm (ECD). Select the plate format according to the expected particle size distribution to avoid truncation of large particles.

Factory Specification Sheet

Selection & Integration Q&A

What are the environmental and duty-cycle limits for the Aura Plus System?

The system is a benchtop laboratory instrument; typical operating conditions for laboratory equipment (e.g., 15–30 °C, <80% RH non-condensing) should be assumed unless the manual states otherwise. Continuous operation is possible with read times of 1 minute/sample (BMI) or 30 seconds/sample (FMM).