Waters Aura PTx System
Waters Aura PTx System — Particle size analyzers.
The Aura PTx System is a benchtop particle size analyzer combining brightfield microscopy (4x objective, 24.6 mm² imaging area, 1.0 pixel/µm resolution) with flow imaging for particles from >1 µm to <5 mm ECD. It delivers BMI results in 1 minute per sample and FMM results in 30 seconds per sample across two FL channels, requiring only 5 µL minimum volume. It is used for rapid, image-based particle characterization in laboratory quality control and formulation workflows.
Direct drop-in replacements
Full specifications
| Imaging area mfr | 24.6 mm2 |
| Optics mfr | 4x objective |
| Minimum volume mfr | 5 μL (assay dependent) |
| Resolution mfr | 1.0 pixel/μm |
| Detectable size range mfr | >1 μm (ECD) to <5 mm (ECD) |
| BMI read time mfr | 1 minute/sample |
| FMM read time mfr | 2 FL channels, 30 seconds/sample |
| Software mfr | Particle Vue 4.x all-in-one Software suite |
Description
Construction and positioning
- Integrated brightfield imaging platform with a 4x objective and a 24.6 mm² field of view, providing 1.0 pixel/µm resolution for morphological analysis. - Flow imaging module with two fluorescence channels for orthogonal particle detection. ### Measurement behavior
- Two read modes: BMI (brightfield morphological imaging) at 1 minute per sample, and FMM (flow microscopy) at 30 seconds per sample using two FL channels. - Detectable size range spans >1 µm to <5 mm equivalent circular diameter (ECD). - Minimum sample volume is 5 µL, assay dependent, enabling low-volume analyses. ### Operation and control
- Controlled via the Particle Vue 4.x all-in-one software suite, which integrates acquisition, analysis, and reporting.
Integration & Operating Notes
Operating below the assay-dependent minimum volume may prevent proper flow imaging and yield invalid results. The 5 µL lower limit must be validated for each assay before routine use, as actual required volume depends on sample concentration and flow cell characteristics.
The system requires the Particle Vue 4.x all-in-one software for operation. Ensure the controlling PC meets the software's system requirements and that the instrument is connected via the specified interface before initiating BMI or FMM runs.
After each use, flush the flow system with appropriate cleaning solution to avoid particle accumulation and clogging, which can degrade imaging quality and cause erroneous size measurements. Follow the manufacturer's cleaning protocol in the instrument manual.
Selection & Integration Q&A
Choose the PTx when you need image-based morphological data (shape, size) from 1 µm to 5 mm with fast read times (1 min BMI, 30 s FMM) and low sample volume (5 µL). For pure ensemble sizing without imaging, a different technique may be more suitable.