Technical Data Sheet — G-BH1 2BH1300 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Side channel blower datasheet for 2BH1 300 (G-BH1 series). Covers 50 Hz and 60 Hz variants, voltage ranges 200-240/345-415 V, 500 V, 575 V, 115/230 V, and alternate-voltage motor variants with VFD option up to 87 Hz.

Technical Data

Parameter Value Condition
Rated pressure 100 mbar p.2 ↗ 2BH1300-1AH06, 50 Hz
Max. differential pressure 100 mbar p.2 ↗ 2BH1300-1AH06, 50 Hz
Voltage 200-240 / 345-415 Y V p.2 ↗ 2BH1300-1AH06, 50 Hz
Current 1,9 A p.2 ↗ 2BH1300-1AH06, 50 Hz
Power 1,1 Y kW p.2 ↗ 2BH1300-1AH06, 50 Hz
Vacuum pressure level -100 mbar p.2 ↗ 2BH1300-1AH06, 50 Hz
Noise level 51 dB(A) p.2 ↗ 2BH1300-1AH06, 50 Hz
Weight 51 kg p.2 ↗ 2BH1300-1AH06, 50 Hz
Rated pressure 100 mbar p.2 ↗ 2BH1300-1AH06, 60 Hz
Max. differential pressure 100 mbar p.2 ↗ 2BH1300-1AH06, 60 Hz
Voltage 220-275 / 380-480 Y V p.2 ↗ 2BH1300-1AH06, 60 Hz
Current 1,74 / 1,0 Y A p.2 ↗ 2BH1300-1AH06, 60 Hz
Power 0,29 kW p.2 ↗ 2BH1300-1AH06, 60 Hz
Vacuum pressure level -100 mbar p.2 ↗ 2BH1300-1AH06, 60 Hz
Noise level 55 dB(A) p.2 ↗ 2BH1300-1AH06, 60 Hz
Weight 55 kg p.2 ↗ 2BH1300-1AH06, 60 Hz
Protection category IP 55 p.1 ↗
Insulation class F p.1 ↗

Operating Limits

  • Max ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Max converter input voltage for standard motor insulation: 460 V p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1300 Type/size designation (side channel blower, size 300)
field 1 p.2 ↗ H / C / P Motor variant / voltage range group
field 2 p.2 ↗ 1 / 3 / 5 / 6 / 7 Voltage/frequency variant code