Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — L-BL2 2BL2101 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BL2 101, compact circuit vacuum pump (L-BL2 range, 'Pump in a Box'), 3~ 50/60 Hz, IP55, insulation class F; ordering code 2BL2101-2 □ K50-□B / Q50-□B with voltage variants K50-1B, K50-6B, Q50-7B and other voltages (K50-3B etc.)

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BL2101, 50 Hz, Δ
Rated voltage 190-210 / 380-420 V p.2 ↗ 2BL2101, 50 Hz, YY / Y
Rated voltage 220-240 V p.2 ↗ 2BL2101, 50 Hz, Δ
Rated voltage 220-240 / 440-480 V p.2 ↗ 2BL2101, 50 Hz, YY / Y
Rated voltage 380-420 / 660-725 V p.2 ↗ 2BL2101, 50 Hz, Δ / Y
Rated voltage 500 V p.2 ↗ 2BL2101, 50 Hz, Y
Rated voltage 575 V p.2 ↗ 2BL2101, 60 Hz, Y
Rated voltage 460 V p.2 ↗ 2BL2101, 60 Hz, Δ
Current 15,3 A p.2 ↗ 2BL2101, 50 Hz, 190-210 V Δ
Current 17,4 / 8,7 A p.2 ↗ 2BL2101, 50 Hz, 190-210 V YY / 380-420 V Y
Current 13,3 A p.2 ↗ 2BL2101, 50 Hz, 220-240 V Δ
Current 15,0 / 7,5 A p.2 ↗ 2BL2101, 50 Hz, 220-240 V YY / 440-480 V Y
Current 7,7 / 4,45 A p.2 ↗ 2BL2101, 50 Hz, 380-420 V Δ / 660-725 V Y
Current 6,0 A p.2 ↗ 2BL2101, 50 Hz, 500 V Y
Current 4,9 A p.2 ↗ 2BL2101, 60 Hz, 575 V Y
Current 6,1 A p.2 ↗ 2BL2101, 60 Hz, 460 V Δ
Power 2,4 kW p.2 ↗ 2BL2101, 50 Hz, IE3
Power 3,5 kW p.2 ↗ 2BL2101, 50/60 Hz, IE3 / NP
Service factor 1,67 - p.2 ↗ 2BL2101, 2,4 kW
Service factor 1,30 - p.2 ↗ 2BL2101, 3,5 kW, IE3
Service factor 1,15 - p.2 ↗ 2BL2101, 3,5 kW, NP
Efficiency class IE3 - p.2 ↗ 2BL2101, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BL2101, 2,4 kW
Sound pressure level 78 dB(A) p.2 ↗ 2BL2101, 3,5 kW
Weight 72 kg p.2 ↗ 2BL2101, 2,4 kW

Operating Limits

  • Protection category: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗
  • Intake temperature for characteristic curves: 20 °C p.1 ↗
  • Characteristic curve tolerance: ± 10 % p.1 ↗
  • Sound pressure level tolerance: ±3 dB(A) p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BL2101 Model range and size (L-BL2 compact circuit vacuum pump, size 101)
8-9 p.2 ↗ -2 Design variant
field 1 p.2 ↗ K / Q Voltage/frequency variant group: K = 50 Hz standard ranges, Q = 50/60 Hz wide-range
field 2 p.2 ↗ 50 Mains frequency 50 Hz (or 50/60 Hz for Q variants)
field 3 p.2 ↗ 1 / 6 / 7 / 3 Voltage code: 1 = 190-210 V Δ / 380-420 V Y; 6 = 220-240 V Δ / 440-480 V Y; 7 = 380-420 V Δ / 660-725 V Y; 3 = other voltages
field 4 p.2 ↗ B Version suffix