Operating Instructions — VGD 4 vacuum pump (BA 234-EN, ed. 1.6 3.12.2019, EN)
Technical Reference Summary
Covered Models & Document Scope
Covers oil-sealed rotary vane vacuum pumps V-VGD 4, V-VGD 8, V-VGD 11, V-VGD 16 and V-VGD 21 (V-Series, Edition 1.6, BA 234-EN). Variants differ in suction capacity, ultimate vacuum, oil type/viscosity (ISO VG 32 for V-VGD 4–16, ISO VG 46 for V-VGD 21), gas ballast valve (V-VGD 16 and 21 only), and mounting (V-VGD 4 not screwed to bearing surface).
Section-by-Section Technical Breakdown
Describes the construction and operating principle of the V-VGD series. The pumps have a fine mesh filter on the suction side and an oil/oil-mist separator on the outlet side returning oil to the circulation. Motor and pump share a common shaft; an integral non-return valve prevents ventilation of the evacuated system after stop.
- Fine mesh filter on suction side; oil and oil mist separator on outlet side
- Motor fan cools motor and pump housing; motor and pump have common shaft
- Integral non-return valve prevents evacuated system from being ventilated after pump stop
- If machine has been idle for more than two minutes, connected pipe should be ventilated to atmospheric pressure
- Gas ballast valve (V-VGD 16 and 21) prevents water vapour condensation inside the pump at operating temperature
Defines the intended use and operating limits of the pumps. Suction capacity at 50 Hz is 4, 8, 10, 15 and 20 m³/h for V-VGD 4, 8, 11, 16 and 21 respectively. Pumps are suitable for evacuation of closed systems but not for continuous operation; switching interval limits and maximum evacuated volume are specified.
- Suction capacity with unrestricted suction at 50 Hz: 4, 8, 10, 15, 20 m³/h (V-VGD 4, 8, 11, 16, 21)
- Not suitable for continuous operation
- Switching interval may not exceed 12 times per hour (start/stop) at 2–100 mbar (abs.) for V-VGD 4, 8, 11, 16 and 1.5–100 mbar (abs.) for V-VGD 21
- Volume to be evacuated must be no more than 2 % of nominal suction capacity
- If installed in open air, unit must be protected from environmental influences (e.g. protective roof)
Covers preparation, mechanical installation, pipe connection, oil filling and motor connection. The machine must be set up horizontally (max. inclination 10° in all directions) and screwed to the bearing surface (not for VGD 4). Electrical installation must be performed by a qualified electrician observing EN 60204.
- Machine may only be operated when set up horizontally (max. inclination 10° in all directions)
- Machine must be screwed to bearing surface to secure against tipping and slipping (not for VGD 4)
- Bearing surface must be plane, even, able to carry weight, and at least same size as machine
- Output reduction noticeable when installed at more than 1000 m above sea level
- Counter pressures on outlet side only permissible up to +0.1 bar
- Only screw in pipes by hand; use flexible connections if necessary
- Fill lubricating oil between max. and min. mark on oil sight glass
- Motor protection switch required; connecting cable installed via cable fitting for strain relief
- Permissible tolerances: ±5 % voltage deviation, ±2 % frequency deviation
- Motors comply with DIN EN 60034, protection class IP 54, insulation class B
Describes commissioning checks, rotation direction verification, decommissioning/storing and re-commissioning. Operating ambient temperature is 10–40 °C and humidity should be less than 85 %. Rotation direction must be checked with a phase sequence indicator; motor fan must rotate anti-clockwise when viewed from the fan.
- Operating ambient temperature 10–40 °C; humidity less than 85 %
- Use phase sequence indicator to check clockwise rotating field
- Start motor briefly (max. two seconds) to check direction; when looking at motor fan, it must rotate anti-clockwise
- After correcting rotation direction, run motor for 2 minutes then top up oil to upper edge of sight glass; filling point must not be open when pump is running
- Decommissioning: switch off, close cut-off devices, disconnect from electricity, depressurise, remove pipes, seal connections with adhesive foil
- Re-commissioning: check condition, drain preserving agents
Specifies maintenance intervals and procedures for air filtering, lubrication and oil separator element replacement. Regular maintenance is required to ensure operational safety. The whole unit should always be kept clean.
- Monthly: check pipes and screws for leaks, check terminal box and cable inlet holes for leaks, clean ventilation slots and motor cooling ribs
- Clean intake air filter depending on how dirty the discharged medium is
- Daily: check oil level
- First oil change after 500 h; subsequent oil changes every 1,500–3,000 h
- Change oil separator element every 1,500–3,000 operating hours
- Oil viscosity must comply with ISO VG 32 (V-VGD 4–16) or ISO VG 46 (V-VGD 21) as per DIN ISO 3448
- Recommended oils: SUPER-LUBE 32 for V-VGD 4–16, SUPER-LUBE 46 for V-VGD 21
- Always change oil when machine is at operating temperature and in an atmospherically ventilated area
- If changing oil type, empty oil removing device housing and oil cooler completely
- Oil separator element cannot be cleaned; replace every 1,500–3,000 operating hours
- Lightly oil O-ring on new oil separator element before fitting
Provides sound pressure level, weight, dimensions, ultimate vacuum, vacuum connection size and correct oil quantity for each model. Values are given for 50 Hz operation; length and weight may differ depending on motor design.
- Sound pressure level (max.) at 50 Hz: 58 dB(A) V-VGD 4, 62 dB(A) V-VGD 8 and 11, 65 dB(A) V-VGD 16 and 21 (tolerance ±3 dB(A), EN ISO 3744)
- Weight: 5.8 kg (V-VGD 4), 11.5 kg (V-VGD 8 and 11), 16 kg (V-VGD 16), 19.5 kg (V-VGD 21)
- Ultimate vacuum: 2 mbar (abs.) for V-VGD 4, 8, 11, 16; 1.5 mbar (abs.) for V-VGD 21
- Vacuum connection: Ø 13 mm (V-VGD 4), Ø 20 mm (V-VGD 8, 11, 16, 21)
- Correct amount of oil: 0.13 l (V-VGD 4), 0.25 l (V-VGD 8 and 11), 0.45 l (V-VGD 16 and 21)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Suction capacity with unrestricted suction at 50 Hz is 4 m³/h (V-VGD 4), 8 m³/h (V-VGD 8), 10 m³/h (V-VGD 11), 15 m³/h (V-VGD 16) and 20 m³/h (V-VGD 21). p.16 ↗ | Used for sizing the pump to the required evacuation flow; note that actual capacity is reduced by narrow or long inlet pipes. | V-VGD 4, 8, 11, 16, 21 |
| Switching interval may not exceed 12 times per hour (start/stop) at a pressure range of 2–100 mbar (abs.) for V-VGD 4, 8, 11 and 16 and 1.5–100 mbar (abs.) for V-VGD 21. p.16 ↗ | Frequent cycling outside these ranges risks oil leaking through the outlet opening and exceeding motor winding/bearing temperature limits. | V-VGD 4, 8, 11, 16, 21 |
| When evacuating closed systems the volume to be evacuated must be no more than 2 % of the nominal suction capacity of the vacuum pump. p.16 ↗ | Limits the allowable connected volume for intermittent evacuation; larger volumes require a larger pump or different operating mode. | V-VGD 4, 8, 11, 16, 21 |
| Machine must only be operated at an ambient temperature and a suction temperature of between 10 and 40 °C. p.7 ↗ | Installation location and process gas temperature must be controlled within this range; contact manufacturer for temperatures outside this range. | V-VGD 4, 8, 11, 16, 21 |
| Counter pressures on the outlet side are only permissible up to +0.1 bar. p.18 ↗ | Exhaust lines must be sized and routed to avoid back pressure exceeding 0.1 bar; never close or constrict exhaust air openings. | V-VGD 4, 8, 11, 16, 21 |
| Permissible voltage deviation is ±5 % and frequency deviation is ±2 %. p.19 ↗ | Mains supply must be within these tolerances of the motor data plate values to avoid loss of power or damage. | V-VGD 4, 8, 11, 16, 21 |
| Motors comply with DIN EN 60034, protection class IP 54 and insulation class B. p.19 ↗ | Electrical installation must be suitable for IP 54 environment; motor protection switch required and connecting cable installed via cable fitting for strain relief. | V-VGD 4, 8, 11, 16, 21 |
| First oil change after 500 hours of operation; subsequent oil changes after 1,500–3,000 hours of operation. p.24 ↗ | Maintenance schedule must include initial 500 h oil change and recurring 1,500–3,000 h changes; reduce intervals depending on contamination of discharged medium. | V-VGD 4, 8, 11, 16, 21 |
| Oil separator element must be replaced every 1,500–3,000 operating hours; it cannot be cleaned. p.25 ↗ | Plan spare part replacement at these intervals; contaminated element increases power consumption and pump temperature and may cause oil ignition in extreme cases. | V-VGD 4, 8, 11, 16, 21 |
| Oil viscosity must comply with ISO VG 32 (V-VGD 4–16) or ISO VG 46 (V-VGD 21) as per DIN ISO 3448. p.24 ↗ | Use only oil of correct viscosity; recommended Elmo Rietschle oils are SUPER-LUBE 32 for V-VGD 4–16 and SUPER-LUBE 46 for V-VGD 21. | V-VGD 4, 8, 11, 16, 21 |
| Correct amount of oil: 0.13 l (V-VGD 4), 0.25 l (V-VGD 8 and 11), 0.45 l (V-VGD 16 and 21). p.30 ↗ | Oil fill quantity for initial fill and refill; oil level must always be visible between max. and min. mark on sight glass. | V-VGD 4, 8, 11, 16, 21 |
| Ultimate vacuum: 2 mbar (abs.) for V-VGD 4, 8, 11, 16; 1.5 mbar (abs.) for V-VGD 21. p.30 ↗ | Defines the maximum vacuum achievable with suction opening closed; selection must consider required final pressure. | V-VGD 4, 8, 11, 16, 21 |
| Vacuum connection: Ø 13 mm (V-VGD 4), Ø 20 mm (V-VGD 8, 11, 16, 21). p.30 ↗ | Pipework and fittings must match these connection sizes; undersized inlet pipe reduces pumping capacity. | V-VGD 4, 8, 11, 16, 21 |
| Sound pressure level (max.) at 50 Hz: 58 dB(A) V-VGD 4, 62 dB(A) V-VGD 8 and 11, 65 dB(A) V-VGD 16 and 21 (tolerance ±3 dB(A), EN ISO 3744). p.30 ↗ | Use ear protection when spending long time near running machine; consider acoustic measures for noise-sensitive installations. | V-VGD 4, 8, 11, 16, 21 |
| Machine may only be operated when set up horizontally with max. inclination 10° in all directions. p.17 ↗ | Mounting surface must be plane and even; machine must be screwed to bearing surface (not for VGD 4) to secure against tipping and slipping. | V-VGD 4, 8, 11, 16, 21 |
| An output reduction is noticeable when installed at more than 1000 m above sea level. p.17 ↗ | For high-altitude installations, contact manufacturer for suitability and possible derating. | V-VGD 4, 8, 11, 16, 21 |
| Storage temperature range: -10 °C to +60 °C; relative humidity 0 % to 80 %. p.11 ↗ | Storage area must meet these conditions; for long-term storage (more than 3 months) use preservation oil rather than operating oil. | V-VGD 4, 8, 11, 16, 21 |
| If the machine has been idle for more than two minutes the connected pipe should be ventilated to atmospheric pressure. p.16 ↗ | Prevents oil from being drawn into the evacuated system due to vacuum remaining in the pipe after pump stop. | V-VGD 4, 8, 11, 16, 21 |
| Gas ballast valve is provided on V-VGD 16 and V-VGD 21 only. p.16 ↗ | For processes with water vapour, select V-VGD 16 or 21; gas ballast prevents condensation inside the pump when low amounts of steam are sucked in at operating temperature. | V-VGD 16, V-VGD 21 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.27 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.27 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.27 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.27 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1 or VDE 0660 Part 102) | |
| Machine is switched off by the motor protection switch p.27 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the intake temperature | Section 2.3 |
| Machine is switched off by the motor protection switch p.27 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 32 / 46 (see pump type) as per DIN ISO 3448 | Section 7.2.2 |
| Machine is switched off by the motor protection switch p.27 ↗ | The oil separator element is dirty. | Change the oil separator element | Section 7.2.3 |
| Machine is switched off by the motor protection switch p.27 ↗ | The back pressure is too high when the exhaust air is being discharged. | Check the hose or the pipe | Section 5.3 |
| Suction capacity is insufficient p.27 ↗ | The suction pipe is too long or too narrow | Check the hose or the pipe | Section 5.3 |
| Suction capacity is insufficient p.27 ↗ | Leak on the suction side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and to ensure that they are firmly seated. | Section 7.2 |
| Suction capacity is insufficient p.27 ↗ | The intake filter is dirty | Clean or replace the intake filter | Section 7.2.1 |
| Final pressure (max. vacuum) is not reached p.27 ↗ | Leak on the suction side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and to ensure that they are firmly seated. | Section 7.2 |
| Final pressure (max. vacuum) is not reached p.27 ↗ | Incorrect oil viscosity | The oil viscosity must comply with ISO VG 32 / 46 (see pump type) as per DIN ISO 3448 | Section 7.2.2 |
| Machine gets too hot p.28 ↗ | Ambient or intake temperature is too high | Ensure it is being used properly | Section 2.3 |
| Machine gets too hot p.28 ↗ | Cooling air supply is obstructed | Check environmental conditions | Section 5.1 |
| Machine gets too hot p.28 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Section 7.2 |
| Machine gets too hot p.28 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 32 / 46 (see pump type) as per DIN ISO 3448 | Section 7.2.2 |
| Machine gets too hot p.28 ↗ | The oil separator element is dirty. | Change the oil separator element | Section 7.2.3 |
| Machine gets too hot p.28 ↗ | The back pressure is too high when the exhaust air is being discharged. | Check the hose or the pipe | Section 5.3 |
| Exhaust air contains visible oil mist p.28 ↗ | The oil separator element is not inserted correctly or the O ring is missing | Check that it is correctly seated | Section 7.2.3 |
| Exhaust air contains visible oil mist p.28 ↗ | Unsuitable oil is being used | Use suitable types | Section 7.2.2 |
| Exhaust air contains visible oil mist p.28 ↗ | The oil separator element is dirty. | Change the oil separator element | Section 7.2.3 |
| Exhaust air contains visible oil mist p.28 ↗ | Ambient or intake temperature is too high | Ensure it is being used properly | Section 2.3 |
| Exhaust air contains visible oil mist p.28 ↗ | Cooling air supply is obstructed | Check environmental conditions | Section 5.1 |
| Exhaust air contains visible oil mist p.28 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Section 7.2 |
| The machine makes a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating t p.29 ↗ | The pump housing is worn (chatter marks) | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating t p.29 ↗ | Blades are damaged | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating t p.29 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the intake temperature | Section 2.3 |
| The machine makes a abnormal noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating t p.29 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 32 / 46 (see pump type) as per DIN ISO 3448 | Section 7.2.2 |
| Water in lubricating oil p.29 ↗ | Pump sucks in water | Install water interceptor upstream of the pump | |
| Water in lubricating oil p.29 ↗ | The pump sucks in more water vapour than is suitable for its water vapour compatibility | Contact the manufacturer for increased gas ballast | |
| Water in lubricating oil p.29 ↗ | Pump only works for a short time and therefore does not reach its normal operating temperature | Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil |