Technical Data Sheet — IE3 vacuum pump DE/EN)
Technical Reference Summary
Covered Models & Document Scope
V-VC 202 XD and V-VC 303 XD oil-flooded rotary vane vacuum pumps with IE3 motors according to UL 1004; suction capacity 200 to 360 m³/h; 50 Hz and 60 Hz variants; voltage variants V-VC xx Vx, Sx, Ux, Tx
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Nominal suction capacity | 200 m³/h p.2 ↗ | V-VC 202, 50 Hz |
| Nominal suction capacity | 240 m³/h p.2 ↗ | V-VC 202, 60 Hz |
| Nominal suction capacity | 300 m³/h p.2 ↗ | V-VC 303, 50 Hz |
| Nominal suction capacity | 360 m³/h p.2 ↗ | V-VC 303, 60 Hz |
| Ultimate vacuum | 3 mbar (abs.) p.2 ↗ | |
| Rated voltage | 230 / 400 V ± 10 % V p.2 ↗ | V-VC 202, 50 Hz |
| Rated voltage | 400 / 690 V ± 10 % V p.2 ↗ | V-VC 303, 50 Hz |
| Rated voltage | 265 / 460 V ± 10 % V p.2 ↗ | V-VC 202, 60 Hz |
| Rated voltage | 460 / - V ± 10 % V p.2 ↗ | V-VC 303, 60 Hz |
| Motor rating | 4,0 kW p.2 ↗ | V-VC 202, 50 Hz |
| Motor rating | 5,5 kW p.2 ↗ | V-VC 303, 50 Hz |
| Motor rating | 6,5 kW p.2 ↗ | V-VC 202, 60 Hz |
| Motor rating | 9,0 kW p.2 ↗ | V-VC 303, 60 Hz |
| Current consumption | 14,3 / 8,2 A p.2 ↗ | V-VC 202, 50 Hz |
| Current consumption | 19,7 / 11,3 A p.2 ↗ | V-VC 303, 50 Hz |
| Current consumption | 19,5 / 11,3 A p.2 ↗ | V-VC 202, 60 Hz |
| Current consumption | 14,7 / - A p.2 ↗ | V-VC 303, 60 Hz |
| Motor efficiency | 89,1 % p.2 ↗ | V-VC 202, 50 Hz |
| Motor efficiency | 89,7 % p.2 ↗ | V-VC 303, 50 Hz |
| Speed | 1465 min-1 p.2 ↗ | 50 Hz |
| Speed | 1765 min-1 p.2 ↗ | 60 Hz |
| Average noise level | 69 dB(A) p.2 ↗ | V-VC 202, 50 Hz, EN ISO 3744 |
| Average noise level | 70 dB(A) p.2 ↗ | V-VC 303, 50 Hz, EN ISO 3744 |
| Max. weight | 195 kg p.2 ↗ | V-VC 202, 50 Hz |
| Max. weight | 205 kg p.2 ↗ | V-VC 303, 50 Hz |
Operating Limits
- Ultimate vacuum: 3 mbar (abs.) p.2 ↗
- Rated voltage tolerance: ± 10 % p.2 ↗
- Suction capacity tolerance: ± 10 % p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.1 ↗ | V-VC | Product series: oil-flooded rotary vane vacuum pump |
| 5-7 p.2 ↗ | 202 / 303 | Size: 202 or 303 |
| 8-9 p.1 ↗ | XD | Model variant |
| voltage field p.2 ↗ | Vx | Voltage variant V: 200/346 V Δ, 200/230 V Y, 400 V Δ |
| voltage field p.2 ↗ | Sx | Voltage variant S: 200/230 V Δ, 400 V Y, 230/460 V Δ |
| voltage field p.2 ↗ | Ux | Voltage variant U: 330/380 V Δ, 660 V Y, 220/380 V Δ, 440 V Y |
| voltage field p.2 ↗ | Tx | Voltage variant T: 200/400 V Δ, 690 V Y, 230/400 V Δ, 460 V Y |