Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — VCS 400 vacuum pump DE/EN)

Technical Reference Summary

Covered Models & Document Scope

Rotary vane vacuum pumps V-VCS 400, 500, 700, 900 (oil-flooded, flange motor, IE3 motors); 50 Hz and 60 Hz data; motor variants HM, UN, HN, HO, KN, JO, JP, KO, HP, HQ, JQ; water-cooled version available on request

Technical Data

Parameter Value Condition
Nominal suction capacity 400 m3/h p.1 ↗ V-VCS 400, 50 Hz
Nominal suction capacity 480 m3/h p.1 ↗ V-VCS 400, 60 Hz
Nominal suction capacity 550 m3/h p.1 ↗ V-VCS 500, 50 Hz
Nominal suction capacity 660 m3/h p.1 ↗ V-VCS 500, 60 Hz
Nominal suction capacity 700 m3/h p.1 ↗ V-VCS 700, 50 Hz
Nominal suction capacity 840 m3/h p.1 ↗ V-VCS 700, 60 Hz
Nominal suction capacity 830 m3/h p.1 ↗ V-VCS 900, 50 Hz
Nominal suction capacity 995 m3/h p.1 ↗ V-VCS 900, 60 Hz
Ultimate vacuum (with gas ballast) 0,5 (10 ‡) mbar (abs.) p.1 ↗ all sizes; ‡ coarse vacuum configuration
Average noise level 73 dB(A) p.1 ↗ V-VCS 400, 50 Hz, EN ISO 3744
Average noise level 75 dB(A) p.1 ↗ V-VCS 400, 60 Hz, EN ISO 3744
Average noise level 75 dB(A) p.1 ↗ V-VCS 500, 50 Hz, EN ISO 3744
Average noise level 77 dB(A) p.1 ↗ V-VCS 500, 60 Hz, EN ISO 3744
Average noise level 78 dB(A) p.1 ↗ V-VCS 700, 50 Hz, EN ISO 3744
Average noise level 80 dB(A) p.1 ↗ V-VCS 700, 60 Hz, EN ISO 3744
Average noise level 79 dB(A) p.1 ↗ V-VCS 900, 50 Hz, EN ISO 3744
Average noise level 81 dB(A) p.1 ↗ V-VCS 900, 60 Hz, EN ISO 3744
Max. weight without motor 357 kg p.1 ↗ V-VCS 400
Max. weight without motor 480 kg p.1 ↗ V-VCS 500
Max. weight without motor 465 kg p.1 ↗ V-VCS 700
Max. weight without motor 555 kg p.1 ↗ V-VCS 900
Oil capacity 12 l p.1 ↗ V-VCS 400
Oil capacity 17,5 l p.1 ↗ V-VCS 500
Oil capacity 17,5 l p.1 ↗ V-VCS 700
Oil capacity 20 l p.1 ↗ V-VCS 900

Operating Limits

  • Ultimate vacuum (with gas ballast): 0,5 mbar (abs.); 10 mbar (abs.) in coarse vacuum configuration p.1 ↗
  • Performance data tolerance: ±10 % (PNEUROP, at 1 bar (abs.) and 20 °C) p.1 ↗
  • Motor voltage tolerance: ±10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.1 ↗ V-VCS Product family: oil-flooded rotary vane vacuum pump
7-9 p.1 ↗ 400 / 500 / 700 / 900 Nominal size (nominal suction capacity class in m3/h at 50 Hz)
mains frequency field p.1 ↗ 50 Hz / 60 Hz Mains frequency for which the performance data apply
voltage field p.1 ↗ 400/690, 330|380/660, 230|460, 220/380|440, 380/660 Motor voltage connection (V ±10 %)